Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 215

The DOI matches its Crossref record.

Sensitivity of end-systolic pressure-dimension and pressure-volume relations to the inotropic state in humans.

Borow, K M, Neumann, A, Wynne, J·1982·Circulation

Abstract

The value for the slope of the left ventricular (LV) end-systolic pressure-dimension and pressure-volume relations has been proposed as a quantitative measure of the LV inotropic state. This measure of LV inotropic state is attractive because it is independent of preload and incorporates afterload. To investigate the sensitivity of the slope of these relations to alterations in contractile state, 10 normal subjects were studied using M-mode echocardiographic, phonocardiographic and indirect carotid pulse recordings during infusion of methoxamine to alter end-systolic pressure and during infusion of dobutamine (5 micrograms/kg/min) to increase LV inotropic state. Heart rate was maintained within a narrow range for each subject. End-systolic volume was calculated from end-systolic echocardiographic dimension by standard methods. End-systolic pressure was estimated from the dicrotic notch pressure determined from a calibrated carotid pulse recording; peak systolic pressure was also measured. Regardless of the method of approximating end-systolic pressure, the positive inotropic intervention caused a leftward shift in the end-systolic pressure-dimension and pressure-volume lines. With the dobutamine infusion, the value for the slope of the end-systolic pressure-dimension relation increased by 25% (range 16-46%, p less than 0.001), while the slope of the end-systolic pressure-volume relation increased by 55% (range 37-85%, p less than 0.001). In all cases, the curves were linear and became steeper with the positive inotropic intervention. In contrast, the value of the slope of the peak systolic pressure-end-systolic dimension relation showed a variable response to the dobutamine infusion (mean change 13%, range -77% to 73%; NS). Although the position of the peak systolic pressure-end-systolic dimension curve is consistently shifted with an alteration in inotropic state, the values of the slope of these curves are not reliable indicators of change in LV contractility. The values for the slope of the line relating end-systolic pressure (estimated by dicrotic notch pressure) to end-systolic dimension or volume, however, are highly sensitive to a change in inotropic state in human subjects.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1161/01.cir.65.5.988

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 215

Metadata

Authors
Borow, K. M., Neumann, A., & Wynne, J.
Venue
Circulation
Published
1982-05
Volume
65
Issue
5
Pages
988-997
ISSN
  • 0009-7322 (ISSN-L)
  • 1524-4539
OpenAlex
W2009243683
Cited by
215
References
0
FWCI
12.42
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Sensitivity of end-systolic pressure-dimension and pressure-volume relations to the inotropic state in humans. https://app.cochat.ai/papers/10.1161/01.cir.65.5.988
The paper
Borow, K. M., Neumann, A., & Wynne, J. (1982). Sensitivity of end-systolic pressure-dimension and pressure-volume relations to the inotropic state in humans. Circulation. https://doi.org/10.1161/01.cir.65.5.988

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.