The DOI matches its Crossref record; 10 of the 10 references it cites were found in a registry or an index.
Noninvasive Doppler determination of cardiac output in man. Clinical validation.
Abstract
A noninvasive technique for assessing cardiac output (CO) was evaluated by comparing it with thermodilution determinations in patients in the intensive care unit. The new method uses pulsed ultrasound to measure aortic diameter and continuous-wave Doppler ultrasound to obtain aortic blood velocity. An initial study evaluating just the velocity measurement showed that changes of the Doppler index of output (DI) correlated well with those of thermodilution cardiac output (TDCO). Linear regression analysis yielded delta DI = 0.87 delta TDCO + 0.14 (r = 0.83, n = 95). Using a university research instrument these measurements were possible in 54 of 60 patients (90%). A second study using a prototype commercial device incorporated the diameter measurement. Ultrasonic cardiac output (UCO), calculated as the time integral of velocity multiplied by the aortic area, was compared to TDCO. The data, obtained from 45 of 53 patients (85%), are described by the linear regression UCO = 0.95TDCO + 0.38 (r = 0.94, n = 110) over a range of 2-11 l/min. Patients with aortic stenosis, aortic insufficiency or a prosthetic valve have been excluded from the second study due to conditions likely to violate the assumptions upon which the calculation of absolute cardiac output is based. These results indicate that accurate CO can be measured by noninvasive ultrasound in most patients. The technique may be useful for extended CO monitoring in acute care patients and for CO assessment in many other types of patients undergoing diagnostic studies and therapeutic interventions.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Medical Therapy of Acute Myocardial Infarction by Application of Hemodynamic Subsets
Forrester, J. S., Diamond, G. A., Chatterjee, K., & Swan, H. J. C. (1976) · New England Journal of Medicine · doi:10.1056/nejm197612092952406 · Cited by 667
Non-invasive assessment of aortic stenosis by Doppler ultrasound.
Hatle, L., Angelsen, B. A., & Tromsdal, A. (1980) · Heart · doi:10.1136/hrt.43.3.284 · Cited by 527
Correlative classification of clinical and hemodynamic function after acute myocardial infarction
Forrester, J. S., Diamond, G. A., & Swan, H. J. C. (1977) · The American Journal of Cardiology · doi:10.1016/s0002-9149(77)80182-3 · Cited by 429
Thermodilution cardiac output: A critical analysis and review of the literature
Levett, J. M., & Replogle, R. L. (1979) · Journal of Surgical Research · doi:10.1016/0022-4804(79)90159-8 · Cited by 241
Relation Between Pressure and Diameter in the Ascending Aorta of Man
Greenfield, J. C., & Patel, D. J. (1962) · Circulation Research · doi:10.1161/01.res.10.5.778 · Cited by 201
Initial Ventricular Impulse: A Potential Key to Cardiac Evaluation
RUSHMER, R. F., Harding, D., Baker, D., & Watson, N. (1964) · Circulation · doi:10.1161/01.cir.29.2.268 · Cited by 191
Non-injurious Ultrasonic Technique for observing Flow in the Human Aorta
Light, L. (1969) · Nature · doi:10.1038/2241119a0 · Cited by 103
Evaluation of the elasticity and characteristic impedance of the ascending aorta in man
Merillon, J. P., Motté, G., Fruchaud, J., Masquet, C., & Gourgon, R. (1978) · Cardiovascular Research · doi:10.1093/cvr/12.7.401 · Cited by 77
Stack, R. S., Sohn, Y. H., & Weissler, A. M. (1981) · The American Journal of Cardiology · doi:10.1016/0002-9149(81)90544-0 · Cited by 38
Prognostic significance of systolic time intervals after recovery from myocardial infarction
Weissler, A. M., O’Neill, W. W., Sohn, Y. H., Stack, R. S., Chew, P. C., & Reed, A. H. (1981) · The American Journal of Cardiology · doi:10.1016/0002-9149(81)90311-8 · Cited by 29
Cited by
Quiñones, M. A., Otto, C. M., Stoddard, M., Waggoner, A., & Zoghbi, W. A. (2002) · Journal of the American Society of Echocardiography · doi:10.1067/mje.2002.120202 · Cited by 2,130
Cheitlin, M. D., Alpert, J. S., Armstrong, W. F., Aurigemma, G. P., Beller, G. A., Bierman, F. Z., Davidson, T. W., Davis, J. L., Douglas, P. S., Gillam, L. D., et al. (1997) · Circulation · doi:10.1161/01.cir.95.6.1686 · Cited by 831
Kumar, A., Anel, R., Bunnell, E., Habet, K., Zanotti, S., Marshall, S., Neumann, A., Ali, A., Cheang, M., Kavinsky, C., et al. (2004) · Critical Care Medicine · doi:10.1097/01.ccm.0000114996.68110.c9 · Cited by 800
Measurement of blood flow by ultrasound: Accuracy and sources of error
Gill, R. W. (1985) · Ultrasound in Medicine & Biology · doi:10.1016/0301-5629(85)90035-3 · Cited by 765
Duvekot, J. J., Cheriex, E. C., Pieters, F. A. A., Menheere, P. P. C. A., & Peeters, L. L. H. (1993) · American Journal of Obstetrics and Gynecology · doi:10.1016/0002-9378(93)90405-8 · Cited by 477
Metadata
- Authors
- Huntsman, L. L., Stewart, D. K., Barnes, S. R., Franklin, S. B., Colocousis, J. S., & Hessel, E. A.
- Venue
- Circulation
- Published
- 1983-03
- Volume
- 67
- Issue
- 3
- Pages
- 593-602
- ISSN
- 0009-7322 (ISSN-L)
- 1524-4539
- OpenAlex
- W2112789217
- Cited by
- 595
- References
- 10
- FWCI
- 50.85
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.