The DOI matches its Crossref record.
Pulmonary artery occlusion pressure and central venous pressure fail to predict ventricular filling volume, cardiac performance, or the response to volume infusion in normal subjects
Abstract
OBJECTIVE: Pulmonary artery occlusion pressure and central venous pressure have been considered to be reliable measures of left and right ventricular preload in patients requiring invasive hemodynamic monitoring. Studies in recent years have questioned the correlation between these estimates of ventricular filling pressures and ventricular end-diastolic volumes/cardiac performance variables in specific patient groups, but clinicians have continued to consider the relationship valid in the broader context. The objective of this study was to assess the relationship between pressure estimates of ventricular preload (pulmonary artery occlusion pressure, central venous pressure) and end-diastolic ventricular volumes/cardiac performance in healthy volunteers. DESIGN: Prospective, nonrandomized, nonblinded interventional study. SETTING: Cardiac catheterization and echocardiography laboratories. SUBJECTS: Normal healthy volunteers (n = 12 group 1, n = 32 group 2). INTERVENTIONS: Pulmonary catheterization and radionuclide cineangiography (group 1) and volumetric echocardiography (group 2) during 3 L of normal saline infusion over 3 hrs. MEASUREMENTS AND MAIN RESULTS: In group 1, the initial pulmonary artery occlusion pressure and central venous pressure did not correlate significantly with initial end-diastolic ventricular volume indexes or cardiac performance (cardiac index and stroke volume index). Changes in pulmonary artery occlusion pressure and central venous pressure following saline infusion also did not correlate with changes in end-diastolic ventricular volume indexes or cardiac performance. In contrast, initial end-diastolic ventricular volume indexes and changes in these ventricular volume indexes in response to 3 L of normal saline loading correlated well with initial stroke volume index and changes in stroke volume index, respectively. The relationship between left ventricular end-diastolic volume index and stroke volume index was confirmed in group 2 subjects using mathematically independent techniques to measure these variables. In addition, initial central venous pressure, right ventricular end-diastolic volume index, pulmonary artery occlusion pressure, and left ventricular end-diastolic volume index failed to correlate significantly with changes in cardiac performance in response to saline infusion in group 1 subjects. CONCLUSIONS: Normal healthy volunteers demonstrate a lack of correlation between initial central venous pressure/pulmonary artery occlusion pressure and both end-diastolic ventricular volume indexes and stroke volume index. Similar results are found with respect to changes in these variables following volume infusion. In contrast, initial end-diastolic ventricular volume indexes and changes in end-diastolic ventricular volume indexes in response to saline loading correlate strongly with initial and postsaline loading changes in cardiac performance as measured by stroke volume index. These data suggest that the lack of correlation of these variables in specific patient groups described in other studies represents a more universal phenomenon that includes normal subjects. Neither central venous pressure nor pulmonary artery occlusion pressure appears to be a useful predictor of ventricular preload with respect to optimizing cardiac performance.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Monitoring of the central blood pressure waveform via a conformal ultrasonic device
Wang, C., Li, X., Hu, H., Zhang, L., Huang, Z., Lin, M., Zhang, Z., Yin, Z., Huang, B., Gong, H., et al. (2018) · Nature Biomedical Engineering · doi:10.1038/s41551-018-0287-x · Cited by 895
Marik, P. E., & Cavallazzi, R. (2013) · Critical Care Medicine · doi:10.1097/ccm.0b013e31828a25fd · Cited by 866
Hong, Y. J., Jeong, H., Cho, K. W., Lu, N., & Kim, D. (2019) · Advanced Functional Materials · doi:10.1002/adfm.201808247 · Cited by 559
Antonelli, M., Levy, M., Andrews, P. J. D., Chastre, J., Hudson, L. D., Manthous, C., Meduri, G. U., Moreno, R. P., Putensen, C., Stewart, T., et al. (2007) · Intensive Care Medicine · doi:10.1007/s00134-007-0531-4 · Cited by 466
Goal-directed fluid management reduces vasopressor and catecholamine use in cardiac surgery patients
Goepfert, M. S. G., Reuter, D. A., Akyol, D., Lamm, P., Kilger, E., & Goetz, A. E. (2007) · Intensive Care Medicine · doi:10.1007/s00134-006-0404-2 · Cited by 254
Metadata
- Authors
- Kumar, A., Anel, R., Bunnell, E., Habet, K., Zanotti, S., Marshall, S., Neumann, A., Ali, A., Cheang, M., Kavinsky, C., & Parrillo, J. E.
- Venue
- Critical Care Medicine
- Published
- 2004-03
- Volume
- 32
- Issue
- 3
- Pages
- 691-699
- ISSN
- 0090-3493 (ISSN-L)
- OpenAlex
- W2146351148
- Cited by
- 800
- References
- 0
- FWCI
- 31.80
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Pulmonary artery occlusion pressure and central venous pressure fail to predict ventricular filling volume, cardiac performance, or the response to volume infusion in normal subjects. https://app.cochat.ai/papers/10.1097/01.ccm.0000114996.68110.c9
- The paper
- Kumar, A., Anel, R., Bunnell, E., Habet, K., Zanotti, S., Marshall, S., Neumann, A., Ali, A., Cheang, M., Kavinsky, C., & Parrillo, J. E. (2004). Pulmonary artery occlusion pressure and central venous pressure fail to predict ventricular filling volume, cardiac performance, or the response to volume infusion in normal subjects. Critical Care Medicine. https://doi.org/10.1097/01.ccm.0000114996.68110.c9
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.