Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 184

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Hemodynamic changes mimicking a vasodilator drug response in the absence of drug therapy after right heart catheterization in patients with chronic heart failure.

Packer, M, Medina, N, Yushak, M·1985·Circulation

Abstract

We suspected that patients with severe chronic heart failure may show hemodynamic changes after cardiac catheterization in the absence of drug therapy that could complicate assessment of the hemodynamic effects of new vasodilator and inotropic agents. To evaluate this phenomenon prospectively, hemodynamic variables were measured in 21 patients with heart failure 30 min and 2, 6, 24, and (in 12 patients) 48 hr after right heart catheterization, during which time therapy was not altered. During the first 2 hr we noted a significant increase in cardiac index and decreases in left ventricular filling pressure, mean arterial pressure, mean right atrial pressure, and systemic vascular resistance (p less than .01); a further decline in left ventricular filling pressure was noted over the next 24 hr, after which all hemodynamic variables remained stable. The magnitude of these hemodynamic changes resembled the effects of many established vasodilator drugs and was further enhanced after meals. These data indicate that hemodynamic improvement may be observed without any therapeutic intervention during the course of invasive studies in patients with severe chronic heart failure; such changes may lead investigators to attribute efficacy to ineffective drug therapy. To minimize the occurrence of such responses, we recommend that intravascular catheters be inserted the day before drug evaluation and that hemodynamic measurements be made with patients in a postprandial state.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1161/01.cir.71.4.761

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

See all 184

Metadata

Authors
Packer, M., Medina, N., & Yushak, M.
Venue
Circulation
Published
1985-04
Volume
71
Issue
4
Pages
761-766
ISSN
  • 0009-7322 (ISSN-L)
  • 1524-4539
OpenAlex
W2013966095
Cited by
184
References
1
FWCI
11.02
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Hemodynamic changes mimicking a vasodilator drug response in the absence of drug therapy after right heart catheterization in patients with chronic heart failure. https://app.cochat.ai/papers/10.1161/01.cir.71.4.761
The paper
Packer, M., Medina, N., & Yushak, M. (1985). Hemodynamic changes mimicking a vasodilator drug response in the absence of drug therapy after right heart catheterization in patients with chronic heart failure. Circulation. https://doi.org/10.1161/01.cir.71.4.761

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.