CoChat

Hydraulic estimation of stenotic orifice area: a correction of the Gorlin formula.

Cannon, S R, Richards, K L, Crawford, M · 1985 · Circulation
Cited by 203

The DOI matches its Crossref record.

Abstract

To determine the source of errors in the Gorlin formula for estimating stenotic valvular orifice area, we used a pulsatile flow model that emulated left ventricular and aortic pressures and flow and allowed control of ventricular outflow orifice area. After comparing orifice areas calculated by the Gorlin formula with actual orifice areas, the Gorlin formula constant (k) was found to be highly correlated with the square root of the mean transvalvular gradient (r = .95). A new formula was derived empirically and predicted areas more accurately and with smaller standard errors than the Gorlin formula in the model (r = .98, SEE = 0.11 and r = .87, SEE = 0.28, respectively) in a series of 19 patients with Hancock porcine xenograft valves (r = .89, SEE = 0.07 and r = .60, SEE = 0.12, respectively) and in the original series of patients reported by Gorlin and Gorlin in proposing the Gorlin formula (r = .93, SEE = 0.11 and r = .91, SEE = 0.12, respectively).

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1161/01.cir.71.6.1170

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 203

Metadata

Authors
Cannon, S. R., Richards, K. L., & Crawford, M.
Venue
Circulation
Published
1985-06
Volume
71
Issue
6
Pages
1170-1178
ISSN
  • 0009-7322 (ISSN-L)
  • 1524-4539
OpenAlex
W1982829795
Cited by
203
References
0
FWCI
6.93
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Hydraulic estimation of stenotic orifice area: a correction of the Gorlin formula. https://app.cochat.ai/papers/10.1161/01.cir.71.6.1170
The paper
Cannon, S. R., Richards, K. L., & Crawford, M. (1985). Hydraulic estimation of stenotic orifice area: a correction of the Gorlin formula. Circulation. https://doi.org/10.1161/01.cir.71.6.1170

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.