The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Atrial fibrillation in patients with Wolff-Parkinson-White syndrome: incidence after surgical ablation of the accessory pathway.
Abstract
The effect of surgical ablation of ablation of atrioventricular accessory pathways on the incidence of atrial fibrillation in patients with Wolff-Parkinson-White syndrome was examined and the results of preoperative electrophysiologic testing were studied to determine factors predictive of outcome. Among 50 consecutive surgical cases, 19 patients were identified with a past history of at least one episode of spontaneous atrial fibrillation documented by electrocardiogram before surgery. The mean number of episodes of atrial fibrillation was 1.97/patient/year during a mean symptomatic period of 6.9 years before surgery. These patients were compared with 19 consecutive patients undergoing surgery during the same time period who had a history of only reciprocating tachycardia. Patients with atrial fibrillation had a significantly shorter antegrade accessory pathway effective refractory period (270 +/- 39 vs 330 +/- 107 msec; p less than .05) and much faster ventricular rates during induced atrial fibrillation (shortest RR interval 219 +/- 73 vs 294 +/- 60 msec, p less than .005; average RR interval 324 +/- 109 vs 405 +/- 127 msec, p less than .01). Patients with atrial fibrillation also had longer PA intervals (47 +/- 13 vs 37 +/- 7 msec; p less than .02). At preoperative electrophysiologic testing, 18 patients with atrial fibrillation had atrial fibrillation induced and 14 sustained the arrhythmia for longer than 10 min. In contrast, atrial fibrillation, although induced in 14 of 19 patients with reciprocating tachycardia, was not sustained in any. Thus electrophysiologic testing suggested that both accessory pathway properties and atrial vulnerability may predispose to atrial fibrillation.(ABSTRACT TRUNCATED AT 250 WORDS)
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Ventricular fibrillation in the Wolff-Parkinson-White syndrome
Klein, G. J., Bashore, T. M., Sellers, T. D., Pritchett, E. L. C., Smith, W. M., & Gallagher, J. J. (1979) · New England Journal of Medicine · doi:10.1056/nejm197911153012003 · Cited by 830
Cited by
Serruys, P. W., Luijten, H. E., Beatt, K. J., Geuskens, R., de Feyter, P. J., van den Brand, M., Reiber, J. H., ten Katen, H. J., van Es, G. A., & Hugenholtz, P. G. (1988) · Circulation · doi:10.1161/01.cir.77.2.361 · Cited by 931
Blomström-Lundqvist, C., Scheinman, M. M., Aliot, E. M., Alpert, J. S., Calkins, H., Camm, A. J., Campbell, W. B., Haines, D. E., Kuck, K. H., Lerman, B. B., et al. (2003) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2003.08.013 · Cited by 689
Guidelines for clinical intracardiac electrophysiological and catheter ablation procedures
Zipes, D. P., Dimarco, J. P., Gillette, P. C., Jackman, W. M., Myerburg, R. J., Rahimtoola, S. H., Ritchie, J. L., Cheitlin, M. D., Garson, A., Gibbons, R. J., et al. (1995) · Journal of the American College of Cardiology · doi:10.1016/0735-1097(95)80037-h · Cited by 282
Metadata
- Authors
- Sharma, A. D., Klein, G. J., Guiraudon, G. M., & Milstein, S.
- Venue
- Circulation
- Published
- 1985-07
- Volume
- 72
- Issue
- 1
- Pages
- 161-169
- ISSN
- 0009-7322 (ISSN-L)
- 1524-4539
- OpenAlex
- W2029667954
- Cited by
- 202
- References
- 1
- FWCI
- 10.39
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Atrial fibrillation in patients with Wolff-Parkinson-White syndrome: incidence after surgical ablation of the accessory pathway. https://app.cochat.ai/papers/10.1161/01.cir.72.1.161
- The paper
- Sharma, A. D., Klein, G. J., Guiraudon, G. M., & Milstein, S. (1985). Atrial fibrillation in patients with Wolff-Parkinson-White syndrome: incidence after surgical ablation of the accessory pathway. Circulation. https://doi.org/10.1161/01.cir.72.1.161
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.