Cited by 931Coronary Interventions and DiagnosticsAcute Myocardial Infarction ResearchCardiac Imaging and Diagnostics

Incidence of restenosis after successful coronary angioplasty: a time-related phenomenon. A quantitative angiographic study in 342 consecutive patients at 1, 2, 3, and 4 months.

Open access
Serruys, P W, Luijten, H E, Beatt, K J, Geuskens, R, de Feyter, P J, van den Brand, M, Reiber, J H, ten Katen, H J +2 more·1988·Circulation

Abstract

Data from experimental, clinical, and pathologic studies have suggested that the process of restenosis begins very early after coronary angioplasty. The present study was performed to determine prospectively the incidence of restenosis with use of the four National Heart, Lung, and Blood Institute and the 50% or greater diameter stenosis criteria, as well as a criterion based on a decrease of 0.72 mm or more in minimal luminal diameter. Patients were recatheterized at 30, 60, 90, or 120 days after successful percutaneous transluminal coronary angioplasty (PTCA). After PTCA all patients received 10 mg nifedipine three to six times a day and aspirin once a day until repeat angiography. Of 400 consecutive patients in whom PTCA was successful (less than 50% diameter stenosis), 342 underwent quantitative angiographic follow-up (86%) by use of an automated edge-detection technique. A wide variation in the incidence of restenosis was found dependent on the criterion applied. The incidence of restenosis proved to be progressive to at least the third month for all except NHLBI criterion II. At 4 months a further increase in the incidence of restenosis was observed when defined as a decrease of 0.72 mm or more in minimal luminal diameter, whereas the criteria based on percentage diameter stenosis showed a variable response. The lack of overlap between the different restenosis criteria applied affirms the arbitrary nature of angiographic definitions currently in use. Restenosis should be assessed by repeat angiography, and preferably ascertained according to the change in absolute quantitative measurements of the luminal diameter.

Integrity signals

Registry

Crossref · 10.1161/01.cir.77.2.361

Cites

34 of 34 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

We couldn’t retrieve this paper’s full text, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Cites

Flagged first, then by citations

Cited by

Sorted by citations

Authors
Serruys, P. W., Luijten, H. E., Beatt, K. J., Geuskens, R., de Feyter, P. J., van den Brand, M., Reiber, J. H., ten Katen, H. J., van Es, G. A., & Hugenholtz, P. G.
Affiliations
  • Erasmus University Rotterdam (NL)
  • Thoraxcenter, Erasmus University, Rotterdam, The Netherlands.
Venue
Circulation
Published
1988-02
Volume
77
Issue
2
Pages
361-371
ISSN
  • 0009-7322 (ISSN-L)
  • 1524-4539
OpenAlex
W2107392339
Cited by
931
References
34
Citations by year
2026: 6 · 2025: 5 · 2024: 4 · 2023: 4 · 2022: 2 · 2021: 6 · 2020: 12 · 2019: 7 · 2018: 10 · 2017: 11 · 2016: 20 · 2015: 11 · 2014: 15 · 2013: 18 · 2012: 9
FWCI
55.81
Type
journal article
Language
en
Open access
Licence
other-oa
Locations
  • Circulation (publishedVersion)
  • PubMed (publishedVersion)
  • RePub (Erasmus University Rotterdam) (submittedVersion, other-oa)
Topics
  • Health Sciences › Medicine › Surgery › Coronary Interventions and Diagnostics
  • Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Acute Myocardial Infarction Research
  • Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Cardiac Imaging and Diagnostics
Keywords
coronary restenosis, percutaneous transluminal coronary angioplasty, quantitative coronary angiography, minimal lumen diameter, nifedipine, aspirin, repeat angiography
MeSH terms
Adult, Aged, Angioplasty, Balloon, Coronary Disease, Coronary Vessels, Female, Follow-Up Studies, Humans, Male, Middle Aged, Recurrence, Vascular Patency, Coronary Angiography

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›