The DOI matches its Crossref record.
Accuracy of volume measurement by conductance catheter in isolated, ejecting canine hearts.
Abstract
We evaluated the accuracy of the recently reported technique of estimating intraventricular volume by measurement of intracavitary electrical conductance in six isolated, ejecting, canine left ventricles. Left ventricular volumes were measured directly by a previously validated servosystem that employed an electroconductive balloon placed in the left ventricular cavity. The volume measured continuously by the balloon method (Vbal) was compared with that estimated by the conductance method (Vcath). For this test, the hearts were made to eject and fill physiologically by the use of a previously described computer-simulated arterial loading system. Complex ejection and filling patterns were created by stimulating the atrium mechanically, which resulted in irregular arrhythmatic contractions spanning a wide range of volumes. We found that there was a highly linear relationship (r2 = .982 +/- .014) between Vbal and Vcath: Vcath = 0.82 (+/- .05) Vbal + 26.7 (+/- 11.8) ml. Despite the wide variation in the offset term of this relationship among the different hearts, the offset within a given heart was predicted within 3.5 ml by a previously detailed "dilution" method that is applicable to the heart in situ within a closed thorax. Thus, since the offset term is obtainable in situ, the conductance method provides a signal that is proportional to the actual volume. To determine whether right ventricular volume influenced the accuracy of left ventricular measurement, we compared the relationship between Vcath and Vbal obtained with right ventricular volumes of 0 and 30 ml. Increasing the right ventricular volume shifted the relationship upward by less than 3 ml in the working range.(ABSTRACT TRUNCATED AT 250 WORDS)
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Influence of contractile state on curvilinearity of in situ end-systolic pressure-volume relations.
Kass, D. A., Beyar, R., Lankford, E., Heard, M., Maughan, W. L., & Sagawa, K. (1989) · Circulation · doi:10.1161/01.cir.79.1.167 · Cited by 268
Self-citationInvasive left ventricle pressure–volume analysis: overview and practical clinical implications
Bastos, M. B., Burkhoff, D., Maly, J., Daemen, J., den Uil, C. A., Ameloot, K., Lenzen, M., Mahfoud, F., Zijlstra, F., Schreuder, J. J., et al. (2020) · European Heart Journal · doi:10.1093/eurheartj/ehz552 · Cited by 237
Self-citation
Metadata
- Authors
- Burkhoff, D., van der Velde, E., Kass, D., Baan, J., Maughan, W. L., & Sagawa, K.
- Venue
- Circulation
- Published
- 1985-08
- Volume
- 72
- Issue
- 2
- Pages
- 440-447
- ISSN
- 0009-7322 (ISSN-L)
- 1524-4539
- OpenAlex
- W2082217011
- Cited by
- 161
- References
- 0
- FWCI
- 2.52
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Accuracy of volume measurement by conductance catheter in isolated, ejecting canine hearts. https://app.cochat.ai/papers/10.1161/01.cir.72.2.440
- The paper
- Burkhoff, D., van der Velde, E., Kass, D., Baan, J., Maughan, W. L., & Sagawa, K. (1985). Accuracy of volume measurement by conductance catheter in isolated, ejecting canine hearts. Circulation. https://doi.org/10.1161/01.cir.72.2.440