The DOI matches its Crossref record.
Further observations on transient entrainment: importance of pacing site and properties of the components of the reentry circuit.
Abstract
Transient entrainment of circus-movement tachycardia utilizing an atrioventricular (AV) bypass pathway was studied in 13 patients (nine with the orthodromic form, two with the antidromic form, and two with both the orthodromic and antidromic forms). All patients had a left-sided AV bypass pathway. Pacing at selected rates faster than the spontaneous rate was performed during the tachycardia at a site proximal or distal to the AV node, an area of slow conduction within the reentry loop. Rapid pacing from a site proximal to the AV node (from the right atrium during the orthodromic form of the arrhythmia or the right ventricle during the antidromic form of the arrhythmia) always demonstrated at least one of the three entrainment criteria: constant fusion beats except for the last captured beat, which was entrained but not fused (first criterion); progressive fusion (second criterion); localized conduction block to a site(s) for 1 paced beat associated with interruption of the tachycardia followed by activation of that site(s) by the next paced beat from a different direction and with a shorter conduction time (third criterion). In contrast, rapid pacing from a site distal to the AV node (from the right ventricle during the orthodromic form of the arrhythmia, or the right atrium during the antidromic form of the arrhythmia) transiently entrained the tachycardia, but never demonstrated any entrainment criteria because the antidromic wave front from the pacing impulse always blocked in the AV node (concealed entrainment). We conclude that the location of the pacing site relative to the components of a reentry loop is critical to the demonstration of the criteria of transient entrainment; i.e., if it is proximal to an area of slow conduction and/or unidirectional block within a reentry loop, transient entrainment should be demonstrable, but if it is distal, it will not be demonstrable.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Olgin, J. E., Kalman, J. M., Fitzpatrick, A. P., & Lesh, M. D. (1995) · Circulation · doi:10.1161/01.cir.92.7.1839 · Cited by 500
Saoudi, N., Cosío, F., Waldo, A., Chen, S. A., Iesaka, Y., Lesh, M., Saksena, S., Salerno, J., & Schoels, W. (2001) · European Heart Journal · doi:10.1053/euhj.2001.2658 · Cited by 464
Radiofrequency catheter ablation of atrial arrhythmias. Results and mechanisms.
Lesh, M. D., Van Hare, G. F., Epstein, L. M., Fitzpatrick, A. P., Scheinman, M. M., Lee, R. J., Kwasman, M. A., Grogin, H. R., & Griffin, J. C. (1994) · Circulation · doi:10.1161/01.cir.89.3.1074 · Cited by 461
Exploring Postinfarction Reentrant Ventricular Tachycardia With Entrainment Mapping
Stevenson, W. G., Friedman, P. L., Sager, P. T., Saxon, L. A., Kocovic, D., Harada, T., Wiener, I., & Khan, H. (1997) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(97)00065-x · Cited by 386
Cauchemez, B., Haissaguerre, M., Fischer, B., Thomas, O., Clementy, J., & Coumel, P. (1996) · Circulation · doi:10.1161/01.cir.93.2.284 · Cited by 312
Metadata
- Authors
- Okumura, K., Henthorn, R. W., Epstein, A. E., Plumb, V. J., & Waldo, A. L.
- Venue
- Circulation
- Published
- 1985-12
- Volume
- 72
- Issue
- 6
- Pages
- 1293-1307
- ISSN
- 0009-7322 (ISSN-L)
- 1524-4539
- OpenAlex
- W2020981209
- Cited by
- 169
- References
- 0
- FWCI
- 6.30
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Further observations on transient entrainment: importance of pacing site and properties of the components of the reentry circuit. https://app.cochat.ai/papers/10.1161/01.cir.72.6.1293
- The paper
- Okumura, K., Henthorn, R. W., Epstein, A. E., Plumb, V. J., & Waldo, A. L. (1985). Further observations on transient entrainment: importance of pacing site and properties of the components of the reentry circuit. Circulation. https://doi.org/10.1161/01.cir.72.6.1293
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.