Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 327

The DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.

Determination of left ventricular end-systolic pressure-volume relationships by the conductance (volume) catheter technique.

Kass, D A, Yamazaki, T, Burkhoff, D, Maughan, W L, Sagawa, K · 1986 · Circulation

Abstract

Using a multielectrode conductance catheter to estimate continuous left ventricular volume we determined the end-systolic pressure-volume relationship (ESPVR) in situ in open-chest anesthetized dogs. Dogs (n = 8) were studied in the control state and after pharmacologic sympathectomy (hexamethonium) and surgical vagotomy both before and after the administration of dobutamine. ESPVR was measured during brief (5 to 6 sec) preload reduction by balloon occlusion of the inferior vena cava (IVCBO). The relationship was highly reproducible. The slope (Ecs) and volume intercept (Vo) (mean +/- SD) in the control series were 5.8 +/- 3.6 mm Hg/ml and 6.5 +/- 12.5 ml, respectively. Upon release of the IVCBO (preload recovery), Ecs was 7.7 +/- 3.6 mm Hg/ml and Vo was 12.4 +/- 9.6 ml (p less than .01). Autonomic blockade produced a 50% reduction in Ecs and a concomitant decrease in Vo (p less than .01), and eliminated the difference between ESPVR generated by preload reduction (IVCBO) and preload recovery (IVCBO release). Subsequent dobutamine infusion increased Ecs to 6.1 +/- 3.5 mm Hg/ml and Vo to 4.1 +/- 6.9 ml, consistent with reported changes of the ESPVR with positive inotropic intervention. A small artifact of right ventricular filling was observed in the left ventricular volume catheter signal, but this did not appreciably alter the ESPVR. These results demonstrate the feasibility of the determination of ESPVR in situ by the conductance catheter and brief IVCBO and underline the importance of the use of rapid load changes to minimize reflex activation during the measurements.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1161/01.cir.73.3.586

Cites

6 of 6 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 6 references

Cited by

See all 327

Metadata

Authors
Kass, D. A., Yamazaki, T., Burkhoff, D., Maughan, W. L., & Sagawa, K.
Venue
Circulation
Published
1986-03
Volume
73
Issue
3
Pages
586-595
ISSN
  • 0009-7322 (ISSN-L)
  • 1524-4539
OpenAlex
W1992309459
Cited by
327
References
6
FWCI
8.87
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Determination of left ventricular end-systolic pressure-volume relationships by the conductance (volume) catheter technique. https://app.cochat.ai/papers/10.1161/01.cir.73.3.586
The paper
Kass, D. A., Yamazaki, T., Burkhoff, D., Maughan, W. L., & Sagawa, K. (1986). Determination of left ventricular end-systolic pressure-volume relationships by the conductance (volume) catheter technique. Circulation. https://doi.org/10.1161/01.cir.73.3.586

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.