Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 247

The DOI matches its Crossref record.

Incomplete lysis of thrombus in the moderate underlying atherosclerotic lesion during intracoronary infusion of streptokinase for acute myocardial infarction: quantitative angiographic observations.

Open access
Brown, B G, Gallery, C A, Badger, R S, Kennedy, J W, Mathey, D, Bolson, E L, Dodge, H T·1986·Circulation

Abstract

Thrombolytic recanalization of the obstructed coronary lumen was studied in 32 patients receiving intracoronary streptokinase for 60 to 90 min during acute myocardial infarction. The process was viewed at high arteriographic magnification and was quantified with computer-assisted measurements from repeated single-plane views. The variability of the method for this application was 0.15 to 0.18 mm on minimum diameter estimates. Structural details were seen that are not commonly appreciated at conventional magnification. The recanalized lumen appears to form along an interface between the thrombus and the vessel wall, progressively enlarging its minimum arteriographic diameter to 0.65 +/- 0.24 mm (+/- 1 SD) at the end of the short-term infusion of streptokinase reflecting a final percent stenosis of 77 +/- 10%. In nine infarct lesions found patent 5 +/- 3 weeks later, the recanalized lumen further improved an average of 0.34 mm in minimum diameter (p less than .005) and 13% stenosis (p less than .01). A thin film of contrast medium surrounding the obstructing thrombus faintly defined the boundaries of the original atherosclerotic lumen in all but two cases. The "original stenosis" measured 1.25 +/- 0.32 mm in minimum diameter and 56 +/- 14% stenosis when first visualized; it was unchanged throughout the course of infusion of streptokinase. In five patients catheterized 10 +/- 12 weeks before their infarction, the original stenosis averaged 1.15 +/- 0.22 mm in the preinfarct angiogram, as compared with 1.17 +/- 0.23 mm in its faintly defined form during thrombolytic therapy (p = NS). In 10 cases, this original lesion was less than a 50% stenosis, and in 21 cases less than 60%.(ABSTRACT TRUNCATED AT 250 WORDS)

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1161/01.cir.73.4.653

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 247

Metadata

Authors
Brown, B. G., Gallery, C. A., Badger, R. S., Kennedy, J. W., Mathey, D., Bolson, E. L., & Dodge, H. T.
Venue
Circulation
Published
1986-04
Volume
73
Issue
4
Pages
653-661
ISSN
  • 0009-7322 (ISSN-L)
  • 1524-4539
OpenAlex
W2072658738
Cited by
247
References
0
FWCI
17.41
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Incomplete lysis of thrombus in the moderate underlying atherosclerotic lesion during intracoronary infusion of streptokinase for acute myocardial infarction: quantitative angiographic observations. https://app.cochat.ai/papers/10.1161/01.cir.73.4.653
The paper
Brown, B. G., Gallery, C. A., Badger, R. S., Kennedy, J. W., Mathey, D., Bolson, E. L., & Dodge, H. T. (1986). Incomplete lysis of thrombus in the moderate underlying atherosclerotic lesion during intracoronary infusion of streptokinase for acute myocardial infarction: quantitative angiographic observations. Circulation. https://doi.org/10.1161/01.cir.73.4.653

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.