Comparison of the defibrillation threshold and the upper limit of ventricular vulnerability.
Open accessThe DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.
Abstract
To examine the relationship between the defibrillation threshold and the strength of shocks that induce ventricular fibrillation during the vulnerable period, we determined the defibrillation threshold in 22 open-chest dogs using epicardial defibrillation electrodes with the cathode at the ventricular apex and the anode at the right atrium. We also determined whether there was an upper limit of shock strength that induces fibrillation in the vulnerable period by giving shocks of various energy through these same electrodes during the repolarization phase of paced rhythm. The above determinations were also made with the anode at the ventricular apex and the cathode at the right atrium in eight of the dogs and with the cathode at the ventricular apex and the anode at the left atrium in another eight of the dogs. In all dogs for all electrode configurations, there was an upper limit to the shock strength that induced ventricular fibrillation during the vulnerable period. Depending on the electrode combination, this upper limit of ventricular vulnerability either was not significantly different from or was slightly lower than the defibrillation threshold. The correlation coefficient between the two was highly significant for all three electrode configurations. These results support the hypothesis that successful defibrillation with epicardial electrodes requires a shock strength that reaches or exceeds the upper limit of ventricular vulnerability and that shocks slightly lower than the defibrillation threshold fail because they reinitiate ventricular fibrillation by stimulating portions of the myocardium during their vulnerable period.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
THE NATURE OF FIBRILLARY CONTRACTION OF THE HEART.—ITS RELATION TO TISSUE MASS AND FORM
Garrey, W. E. (1914) · American Journal of Physiology-Legacy Content · doi:10.1152/ajplegacy.1914.33.3.397 · Cited by 560
Termination of ventricular fibrillation in dogs by depolarizing a critical amount of myocardium
Zipes, D. P., Fischer, J., King, R. M., deB. Nicoll, A., & Jolly, W. W. (1975) · The American Journal of Cardiology · doi:10.1016/0002-9149(75)90865-6 · Cited by 487 · cited 1×
“This hypothesis raises the possibility that (1) if an electrode combination can be developed with a uniform field through the ventricles and (2) if the depolarization threshold is lower than the fibrillation threshold during ventricular fibrillation, then defibrillation can be achieved at much lower energy by depolari…”
BackgroundWiggers, C. J., & Wégria, R. (1940) · American Journal of Physiology-Legacy Content · doi:10.1152/ajplegacy.1940.128.3.500 · Cited by 411
Chen, P. S., Shibata, N., Dixon, E. G., Wolf, P. D., Danieley, N. D., Sweeney, M. B., Smith, W. M., & Ideker, R. E. (1986) · Journal of Clinical Investigation · doi:10.1172/jci112378 · Cited by 236
Self-citationSudden Cardiac Death: A Problem in Topology
Winfree, A. T. (1983) · Scientific American · doi:10.1038/scientificamerican0583-144 · Cited by 166
Effect of pentobarbital anesthesia on ventricular defibrillation threshold in dogs
Babbs, C. F. (1978) · American Heart Journal · doi:10.1016/0002-8703(78)90364-2 · Cited by 87
Data analysis programs for the UNIX operating system
Perlman, G. (1980) · Behavior Research Methods · doi:10.3758/bf03201835 · Cited by 30
Cited by
Use of Automated External Defibrillators by a U.S. Airline
Page, R. L., Joglar, J. A., Kowal, R. C., Zagrodzky, J. D., Nelson, L. L., Ramaswamy, K., Barbera, S. J., Hamdan, M. H., & McKenas, D. K. (2000) · New England Journal of Medicine · doi:10.1056/nejm200010263431702 · Cited by 632
Frazier, D. W., Wolf, P. D., Wharton, J. M., Tang, A. S., Smith, W. M., & Ideker, R. E. (1989) · Journal of Clinical Investigation · doi:10.1172/jci113945 · Cited by 386
Self-citationElectrical instability in cardiac muscle: Phase singularities and rotors
Winfree, A. T. (1989) · Journal of Theoretical Biology · doi:10.1016/s0022-5193(89)80200-0 · Cited by 311
Virtual Electrode–Induced Phase Singularity: A Basic Mechanism of Defibrillation Failure
Efimov, I. R., Cheng, Y., Van Wagoner, D. R., Mazgalev, T., & Tchou, P. J. (1998) · Circulation Research · doi:10.1161/01.res.82.8.918 · Cited by 290
Origins of Spiral Wave Meander and Breakup in a Two-Dimensional Cardiac Tissue Model
Qu, Z., Xie, F., Garfinkel, A., & Weiss, J. N. (2000) · Annals of Biomedical Engineering · doi:10.1114/1.1289474 · Cited by 182
SIMS, J. J., MILLER, A. W., & UJHELYI, M. R. (2000) · Journal of Cardiovascular Electrophysiology · doi:10.1111/j.1540-8167.2000.tb00025.x · Cited by 27
Metadata
- Authors
- Chen, P. S., Shibata, N., Dixon, E. G., Martin, R. O., & Ideker, R. E.
- Venue
- Circulation
- Published
- 1986-05
- Volume
- 73
- Issue
- 5
- Pages
- 1022-1028
- ISSN
- 0009-7322 (ISSN-L)
- 1524-4539
- OpenAlex
- W2015146179
- Cited by
- 249
- References
- 7
- FWCI
- 2.96
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.