Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 326

The DOI matches its Crossref record; 10 of the 10 references it cites were found in a registry or an index.

Prediction of the physiologic significance of coronary arterial lesions by quantitative lesion geometry in patients with limited coronary artery disease.

Open access
Wilson, R F, Marcus, M L, White, C W · 1987 · Circulation

Abstract

Studies in animals with normal coronary arteries have shown that coronary flow reserve can be predicted by angiographic measurements of arterial stenosis. Studies in man, however, suggest that even quantitative analysis of coronary angiograms cannot predict the physiologic significance of individual coronary lesions. These studies, however, were carried out in patients with either widespread, diffuse coronary artery disease or by measurement techniques that tend to underestimate maximal coronary flow reserve. To determine the relationship between coronary arterial stenosis and coronary flow reserve (CFR) in patients with discrete limited coronary atherosclerosis, we studied 50 patients with a single discrete coronary stenosis in only one or two vessels. The minimum coronary arterial cross-sectional area (mCSA), percent area stenosis (%AS), and percent diameter stenosis in the left and right anterior oblique projections were determined by the Brown/Dodge method of quantitative coronary angiography. A No. 3F coronary Doppler catheter was placed immediately proximal to the lesion. Measurements of CFR were obtained by intracoronary administration of papaverine in doses sufficient to provide maximal arteriolar vasodilation. In 25 patients, a translesional pressure gradient was obtained with an angioplasty catheter. CFR measured in patients with coronary artery disease was compared with that in 13 patients with normal coronary vessels. In normal patients, CFR averaged 5.0 +/- 0.6 (peak/resting velocity ratio; mean +/- SEM, range 3.7 to 8.2). In patients with limited coronary artery disease, CFR was closely correlated with %AS (r = .85), mCSA (r = .79), and the translesional pressure gradient (r = .83). Additionally, the most severe percent diameter stenosis in either the left or right anterior oblique view was also highly correlated with CFR (r = .82). Importantly, all arteries with lesions producing less than 70% area stenosis and less than 50% diameter stenosis, or with greater than 2.5 mm2 mCSA had CFR of over 3.5. These results suggest that, in contrast to the poor correlation of percent area and percent diameter stenosis to CFR measured in patients with multivessel coronary artery disease, CFR measured at angiography in patients with discrete, limited coronary artery disease correlates closely with luminal stenosis determined precisely with quantitative coronary angiography. Differences in the extent of diffuse arterial narrowing may account for these discrepancies.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1161/01.cir.75.4.723

Cites

10 of 10 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 10 references

Cited by

See all 326

Metadata

Authors
Wilson, R. F., Marcus, M. L., & White, C. W.
Venue
Circulation
Published
1987-04
Volume
75
Issue
4
Pages
723-732
ISSN
  • 0009-7322 (ISSN-L)
  • 1524-4539
OpenAlex
W1994403762
Cited by
326
References
10
FWCI
22.39
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Prediction of the physiologic significance of coronary arterial lesions by quantitative lesion geometry in patients with limited coronary artery disease. https://app.cochat.ai/papers/10.1161/01.cir.75.4.723
The paper
Wilson, R. F., Marcus, M. L., & White, C. W. (1987). Prediction of the physiologic significance of coronary arterial lesions by quantitative lesion geometry in patients with limited coronary artery disease. Circulation. https://doi.org/10.1161/01.cir.75.4.723

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.