Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 281

The DOI matches its Crossref record; 22 of the 22 references it cites were found in a registry or an index.

Cardiorespiratory responses to exercise training after orthotopic cardiac transplantation.

Kavanagh, T, Yacoub, M H, Mertens, D J, Kennedy, J, Campbell, R B, Sawyer, P · 1988 · Circulation

Abstract

We have tested the feasibility and effectiveness of a 2 year (average 16 +/- 7 months) walk/jog exercise program on 36 male orthotopic cardiac transplant patients (21 to 57 years old) seen initially 2 to 23 months after surgery. Comparison of initial exercise test results with those in 45 age-matched normal men showed the patients to have a lesser lean body mass (56 +/- 7 vs 63 +/- 8 kg, p less than .001), with a higher resting heart rate (104 +/- 12 vs 77 +/- 14 beats/min, p less than .001) and systolic (138 +/- 16 vs 129 +/- 17 mm Hg, p less than .001) and diastolic (95 +/- 14 vs 84 +/- 10 mm Hg, p less than .001) blood pressures. Peak power output was less than normal (101 +/- 27 vs 219 +/- 41 W, p less than .001), as was peak heart rate (136 +/- 15 vs 176 +/- 13 beats/min, p less than .001), peak oxygen intake (VO2max) (22 +/- 5 vs 34 +/- 6 ml.kg.min-1, p less than .001), and absolute anaerobic threshold (1.18 +/- 0.40 vs 2.04 +/- 0.40 liters.min-1, p less than .001). Peak ventilatory equivalent was higher (48 +/- 9 vs 37 +/- 61.1-1, p less than .001). Cardiac output (Q), as estimated by the CO2 rebreathing method, was slightly above normal at rest (p less than .01), but below normal at two submaximal work rates. The group's average weekly training distance was 24 km, with eight highly compliant patients progressing to 32 km or more weekly. After training, lean tissue increased (+2.4 +/- 3.1 kg, p less than .001), and resting values were reduced for heart rate (-4 +/- 11 beats/min, p less than .05), systolic (-13 +/- 20 mm Hg, p less than .001), and diastolic (-9 +/- 17 mm Hg, p less than .001) blood pressures. There were significant reductions in submaximal values for minute ventilation (VE), ratings of perceived exertion, and diastolic blood pressure at equivalent workloads. Peak values increased for power output (+49 +/- 34 W, p less than .001), VO2max (+4.0 +/- 6.0 ml.kg.min-1, p less than .001), VE (+20 +/- 20 l.min-1, p less than .001), and heart rate (+13 +/- 17 beats/min, p less than .001), and decreased for diastolic blood pressure (-8 +/- 15 mm Hg, p less than .001).(ABSTRACT TRUNCATED AT 400 WORDS)

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1161/01.cir.77.1.162

Cites

22 of 22 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 22 references

Cited by

See all 281

Metadata

Authors
Kavanagh, T., Yacoub, M. H., Mertens, D. J., Kennedy, J., Campbell, R. B., & Sawyer, P.
Venue
Circulation
Published
1988-01
Volume
77
Issue
1
Pages
162-171
ISSN
  • 0009-7322 (ISSN-L)
  • 1524-4539
OpenAlex
W2151267784
Cited by
281
References
22
FWCI
18.79
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Cardiorespiratory responses to exercise training after orthotopic cardiac transplantation. https://app.cochat.ai/papers/10.1161/01.cir.77.1.162
The paper
Kavanagh, T., Yacoub, M. H., Mertens, D. J., Kennedy, J., Campbell, R. B., & Sawyer, P. (1988). Cardiorespiratory responses to exercise training after orthotopic cardiac transplantation. Circulation. https://doi.org/10.1161/01.cir.77.1.162

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.