Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 178

The DOI matches its Crossref record.

Influence of compression rate on initial success of resuscitation and 24 hour survival after prolonged manual cardiopulmonary resuscitation in dogs.

Open access
Feneley, M P, Maier, G W, Kern, K B, Gaynor, J W, Gall, S A, Sanders, A B, Raessler, K, Muhlbaier, L H, Rankin, J S, Ewy, G A · 1988 · Circulation

Abstract

The influence of chest compression rate on initial resuscitation success and 24 hr survival after prolonged manual cardiopulmonary resuscitation (CPR) was investigated in 26 morphine-anesthetized dogs (17 to 30 kg). After placement of aortic and right atrial micromanometers and induction of ventricular fibrillation, manual CPR was commenced immediately and continued for 30 min. One group of 13 dogs underwent manual CPR at a compression rate of 60/min, and the other group at a rate of 120/min. The compression durations in the two groups were not significantly different (51.7 +/- 1.8% at 60/min vs 51.6 +/- 1.9% at 120/min). No drugs other than sodium bicarbonate were administered during CPR. A maximum of three attempts was permitted to defibrillate the heart. Successfully defibrillated animals were followed for 24 hr, during which time no treatment, other than naloxone, was given to reverse the effects of morphine. Arterial blood pH, PCO2, and PO2 were not significantly different in the two groups throughout the CPR period. When compared with the compression rate of 60/min, the compression rate of 120/min produced more successfully defibrillated animals (12/13 at 120/min vs 2/13 at 60/min, p less than .002) and more 24 hr survivors (8/13 at 120/min vs 2/13 at 60/min, p less than .03). All 24 hr survivors were conscious and able to sit, stand, and drink normally. One 24 hr survivor in each group had difficulty walking. Improved survival with the high-rate compression technique was consistent with the significantly higher mean aortic (systolic and diastolic) and coronary perfusion pressures attained with high-rate compressions (all p less than .002). Although the clinical applicability of these findings has yet to be demonstrated, they provide empirical support for the recent decision to increase the chest compression rate for manual CPR recommended by the American Heart Association, and indicate that the hemodynamic and survival benefits of faster compression rates in this experimental preparation were not dependent on covariant alterations in compression duration.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1161/01.cir.77.1.240

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 178

Metadata

Authors
Feneley, M. P., Maier, G. W., Kern, K. B., Gaynor, J. W., Gall, S. A., Sanders, A. B., Raessler, K., Muhlbaier, L. H., Rankin, J. S., & Ewy, G. A.
Venue
Circulation
Published
1988-01
Volume
77
Issue
1
Pages
240-250
ISSN
  • 0009-7322 (ISSN-L)
  • 1524-4539
OpenAlex
W2064157579
Cited by
178
References
0
FWCI
5.69
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Influence of compression rate on initial success of resuscitation and 24 hour survival after prolonged manual cardiopulmonary resuscitation in dogs. https://app.cochat.ai/papers/10.1161/01.cir.77.1.240
The paper
Feneley, M. P., Maier, G. W., Kern, K. B., Gaynor, J. W., Gall, S. A., Sanders, A. B., Raessler, K., Muhlbaier, L. H., Rankin, J. S., & Ewy, G. A. (1988). Influence of compression rate on initial success of resuscitation and 24 hour survival after prolonged manual cardiopulmonary resuscitation in dogs. Circulation. https://doi.org/10.1161/01.cir.77.1.240

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.