The DOI matches its Crossref record; 68 of the 68 references it cites were found in a registry or an index.
Quality of Cardiopulmonary Resuscitation During Out-of-Hospital Cardiac Arrest
Abstract
CONTEXT: Cardiopulmonary resuscitation (CPR) guidelines recommend target values for compressions, ventilations, and CPR-free intervals allowed for rhythm analysis and defibrillation. There is little information on adherence to these guidelines during advanced cardiac life support in the field. OBJECTIVE: To measure the quality of out-of-hospital CPR performed by ambulance personnel, as measured by adherence to CPR guidelines. DESIGN AND SETTING: Case series of 176 adult patients with out-of-hospital cardiac arrest treated by paramedics and nurse anesthetists in Stockholm, Sweden, London, England, and Akershus, Norway, between March 2002 and October 2003. The defibrillators recorded chest compressions via a sternal pad fitted with an accelerometer and ventilations by changes in thoracic impedance between the defibrillator pads, in addition to standard event and electrocardiographic recordings. MAIN OUTCOME MEASURE: Adherence to international guidelines for CPR. RESULTS: Chest compressions were not given 48% (95% CI, 45%-51%) of the time without spontaneous circulation; this percentage was 38% (95% CI, 36%-41%) when subtracting the time necessary for electrocardiographic analysis and defibrillation. Combining these data with a mean compression rate of 121/min (95% CI, 118-124/min) when compressions were given resulted in a mean compression rate of 64/min (95% CI, 61-67/min). Mean compression depth was 34 mm (95% CI, 33-35 mm), 28% (95% CI, 24%-32%) of the compressions had a depth of 38 mm to 51 mm (guidelines recommendation), and the compression part of the duty cycle was 42% (95% CI, 41%-42%). A mean of 11 (95% CI, 11-12) ventilations were given per minute. Sixty-one patients (35%) had return of spontaneous circulation, and 5 of 6 patients discharged alive from the hospital had normal neurological outcomes. CONCLUSIONS: In this study of CPR during out-of-hospital cardiac arrest, chest compressions were not delivered half of the time, and most compressions were too shallow. Electrocardiographic analysis and defibrillation accounted for only small parts of intervals without chest compressions.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Gandevia, B., & Tovell, A. (1964) · PubMed · Cited by 2,069
Cummins, R. O., Chamberlain, D. A., Abramson, N. S., Allen, M., Baskett, P. J., Becker, L., Bossaert, L., Delooz, H. H., Dick, W. F., & Eisenberg, M. S. (1991) · Circulation · doi:10.1161/01.cir.84.2.960 · Cited by 1,670
Outcomes of Rapid Defibrillation by Security Officers after Cardiac Arrest in Casinos
Valenzuela, T. D., Roe, D. J., Nichol, G., Clark, L. L., Spaite, D. W., & Hardman, R. G. (2000) · New England Journal of Medicine · doi:10.1056/nejm200010263431701 · Cited by 1,485
Predicting survival from out-of-hospital cardiac arrest: A graphic model
Larsen, M. P., Eisenberg, M. S., Cummins, R. O., & Hallstrom, A. P. (1993) · Annals of Emergency Medicine · doi:10.1016/s0196-0644(05)81302-2 · Cited by 1,254
Peberdy, M. A., Kaye, W., Ornato, J. P., Larkin, G. L., Nadkarni, V., Mancini, M. E., Berg, R. A., Nichol, G., & Lane-Trultt, T. (2003) · Resuscitation · doi:10.1016/s0300-9572(03)00215-6 · Cited by 1,242
Quality of Cardiopulmonary Resuscitation During In-Hospital Cardiac Arrest
Abella, B. S. (2005) · JAMA · doi:10.1001/jama.293.3.305 · Cited by 1,185
Paradis, N. A. (1990) · JAMA: The Journal of the American Medical Association · doi:10.1001/jama.1990.03440080084029 · Cited by 1,061
Chamberlain, D., Cummins, R. O., Abramson, N., Allen, M., Baskett, P., Becker, L., Bossaert, L., Delooz, H., Dick, W., Eisenberg, M., et al. (1991) · Resuscitation · doi:10.1016/0300-9572(91)90061-3 · Cited by 914
Hyperventilation-Induced Hypotension During Cardiopulmonary Resuscitation
Aufderheide, T. P., Sigurdsson, G., Pirrallo, R. G., Yannopoulos, D., McKnite, S., von Briesen, C., Sparks, C. W., Conrad, C. J., Provo, T. A., & Lurie, K. G. (2004) · Circulation · doi:10.1161/01.cir.0000126594.79136.61 · Cited by 886
Cited by
Field, J. M., Hazinski, M. F., Sayre, M. R., Chameides, L., Schexnayder, S. M., Hemphill, R., Samson, R. A., Kattwinkel, J., Berg, R. A., Bhanji, F., et al. (2010) · Circulation · doi:10.1161/circulationaha.110.970889 · Cited by 1,050
(2007) · The Lancet · doi:10.1016/s0140-6736(07)60451-6 · Cited by 533
Breitkreutz, R., Walcher, F., & Seeger, F. H. (2007) · Critical Care Medicine · doi:10.1097/01.ccm.0000260626.23848.fc · Cited by 417
Kleinman, M. E., de Caen, A. R., Chameides, L., Atkins, D. L., Berg, R. A., Berg, M. D., Bhanji, F., Biarent, D., Bingham, R., Coovadia, A. H., et al. (2010) · Pediatrics · doi:10.1542/peds.2010-2972a · Cited by 86
Nord, A., Svensson, L., Karlsson, T., Claesson, A., Herlitz, J., & Nilsson, L. (2017) · Resuscitation · doi:10.1016/j.resuscitation.2017.08.234 · Cited by 27
Metadata
- Authors
- Wik, L.
- Venue
- JAMA
- Publisher
- American Medical Association (AMA)
- Published
- 2005-01-19
- Volume
- 293
- Issue
- 3
- Pages
- 299
- ISSN
- 0002-9955 (ISSN-L)
- 0098-7484
- OpenAlex
- W2161252442
- Cited by
- 1,538
- References
- 68
- FWCI
- 116.94
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Quality of Cardiopulmonary Resuscitation During Out-of-Hospital Cardiac Arrest. https://app.cochat.ai/papers/10.1001/jama.293.3.299
- The paper
- Wik, L. (2005). Quality of Cardiopulmonary Resuscitation During Out-of-Hospital Cardiac Arrest. JAMA. https://doi.org/10.1001/jama.293.3.299
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.