The DOI matches its Crossref record.
Evaluation of nonradioactive, colored microspheres for measurement of regional myocardial blood flow in dogs.
Abstract
Measurement of regional myocardial blood flow (RMBF) is crucial in experimental studies of myocardial ischemia and reperfusion in dogs. The standard measurement technique uses radioactive microspheres; however, not all institutions are able to dispose of radioactive waste and therefore cannot make use of this method. We tested a new, nonradioactive microsphere, labeled with colors instead of nuclides. Simultaneous blood flow measurements with two nuclide-labeled and two colored microspheres were performed after coronary occlusion in dogs. Both techniques show a within-method correlation of r greater than 0.98. Duplicate variability for paired RMBF values in 80 samples was 8.7 +/- 0.1% when computed with radioactive microspheres and 13.2 +/- 1.8% when computed with colored microspheres. There was a good correlation in the measurement of RMBF between the radioactive- and colored-microsphere methods (r = 0.98). The best-fitting linear regression line was expressed by the formula: Colored-microsphere RMBF = 1.11 (radioactive-microsphere RMBF)-0.02. When measured by colored microspheres, RMBF was approximately 8% higher than when computed with radioactive microspheres for blood flow values of 0-2 ml/min/g. When blood flow was increased pharmacologically to levels of 2-7.5 ml/min/g, colored microspheres yielded blood flow values 39% higher than the values computed by radioactive microspheres. We conclude that the nonradioactive, colored-microsphere method correlates with the radioactive technique, but at high flows, it yields values greater than those obtained with radioactive microspheres.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Validation of fluorescent-labeled microspheres for measurement of regional organ perfusion
Glenny, R. W., Bernard, S., & Brinkley, M. (1993) · Journal of Applied Physiology · doi:10.1152/jappl.1993.74.5.2585 · Cited by 365
Coronary circulation in dogs with an experimental decrease in aortic compliance
Watanabe, H., Ohtsuka, S., Kakihana, M., & Sugishita, Y. (1993) · Journal of the American College of Cardiology · doi:10.1016/0735-1097(93)90330-4 · Cited by 278
Pagani, F. D., Baker, L. S., Hsi, C., Knox, M., Fink, M. P., & Visner, M. S. (1992) · Journal of Clinical Investigation · doi:10.1172/jci115873 · Cited by 278
Metadata
- Authors
- Hale, S. L., Alker, K. J., & Kloner, R. A.
- Venue
- Circulation
- Published
- 1988-08
- Volume
- 78
- Issue
- 2
- Pages
- 428-434
- ISSN
- 0009-7322 (ISSN-L)
- 1524-4539
- OpenAlex
- W2086165844
- Cited by
- 211
- References
- 0
- FWCI
- 3.11
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Evaluation of nonradioactive, colored microspheres for measurement of regional myocardial blood flow in dogs. https://app.cochat.ai/papers/10.1161/01.cir.78.2.428
- The paper
- Hale, S. L., Alker, K. J., & Kloner, R. A. (1988). Evaluation of nonradioactive, colored microspheres for measurement of regional myocardial blood flow in dogs. Circulation. https://doi.org/10.1161/01.cir.78.2.428
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.