Validation of fluorescent-labeled microspheres for measurement of regional organ perfusion
Abstract
Estimations of dog lung, pig heart, and pig kidney regional perfusion by use of fluorescent-labeled microspheres were compared with measurements obtained with standard radiolabeled microspheres. Pairs of radio- and fluorescent-labeled microspheres (15 microns diam, 6 colors) were injected into a central vein of a supine anesthetized dog and the left ventricle of three supine anesthetized pigs while reference blood samples were simultaneously withdrawn from a femoral artery in the pigs. The lungs were cubed into approximately 2 cm3 pieces (n = 1,510). Each pig heart and kidney was cubed into approximately 1-g pieces (total n = 192 and 120, respectively). The radioactivity of each organ piece and reference blood sample was determined using a scintillation counter with count rates corrected for decay, background, and spillover. Tissue samples and reference blood samples were digested with KOH and filtered and the fluorescent dye was extracted with a solvent, or the dye was extracted from lung tissue without filtering. The fluorescence of each sample was determined for each color by use of an automated spectrophotometer. Perfusion was calculated for each organ piece from both the radioactivity and fluorescence. Correlation between flow determined by radio- and fluorescent-labeled microspheres was as follows: r = 0.96 +/- 0.01 (SD) (lung, filtered, n = 588), r = 0.99 +/- 0.00 (lung, nonfiltered, n = 710), r = 0.95 +/- 0.02 (heart, filtered), and r = 0.96 +/- 0.02 (kidney, filtered). Compared with colored microspheres, methods for quantitating fluorescent-labeled microspheres are more sensitive, less labor intensive, and less expensive. Fluorescent-labeled microspheres provide a new nonradioactive method for single and repeated measurement of regional organ perfusion.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
Martin Bland, J., & Altman, D. (1986) · The Lancet · doi:10.1016/s0140-6736(86)90837-8 · Cited by 47,965
Blood flow measurements with radionuclide-labeled particles
Heymann, M. A., Payne, B. D., Hoffman, J. I. E., & Rudolph, A. M. (1977) · Progress in Cardiovascular Diseases · doi:10.1016/s0033-0620(77)80005-4 · Cited by 2,036
RUDOLPH, A. M., & HEYMANN, M. A. (1967) · Circulation Research · doi:10.1161/01.res.21.2.163 · Cited by 1,316
Some sources of error in measuring regional blood flow with radioactive microspheres.
Buckberg, G. D., Luck, J. C., Payne, D. B., Hoffman, J. I., Archie, J. P., & Fixler, D. E. (1971) · Journal of Applied Physiology · doi:10.1152/jappl.1971.31.4.598 · Cited by 1,132
Measurement of regional myocardial blood flow with multiple colored microspheres.
Kowallik, P., Schulz, R., Guth, B. D., Schade, A., Paffhausen, W., Gross, R., & Heusch, G. (1991) · Circulation · doi:10.1161/01.cir.83.3.974 · Cited by 375
Use and Interpretation of Common Statistical Tests in Method Comparison Studies
Westgard, J. O. (2008) · Clinical Chemistry · doi:10.1373/clinchem.2007.094060 · Cited by 310
Hale, S. L., Alker, K. J., & Kloner, R. A. (1988) · Circulation · doi:10.1161/01.cir.78.2.428 · Cited by 213
Effect of velocity distribution on red cell distribution in capillary blood vessels
Yen, R. T., & Fung, Y. C. (1978) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.1978.235.2.h251 · Cited by 135
Validity of microsphere depositions for regional myocardial flows
Bassingthwaighte, J. B., Malone, M. A., Moffett, T. C., King, R. B., Little, S. E., Link, J. M., & Krohn, K. A. (1987) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.1987.253.1.h184 · Cited by 123
New nonradioactive microspheres and more sensitive X-ray fluorescence to measure regional blood flow
Mori, H., Haruyama, S., Shinozaki, Y., Okino, H., Iida, A., Takanashi, R., Sakuma, I., Husseini, W. K., Payne, B., & Hoffman, J. I. E. (1992) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.1992.263.6.h1946 · Cited by 76
Cited by
Guidelines for experimental models of myocardial ischemia and infarction
Lindsey, M. L., Bolli, R., Canty, J. M., Du, X.-J., Frangogiannis, N. G., Frantz, S., Gourdie, R. G., Holmes, J. W., Jones, S. P., Kloner, R. A., et al. (2018) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.00335.2017 · Cited by 526
Metadata
- Authors
- Glenny, R. W., Bernard, S., & Brinkley, M.
- Venue
- Journal of Applied Physiology
- Publisher
- American Physiological Society
- Published
- 1993-05-01
- Volume
- 74
- Issue
- 5
- Pages
- 2585-2597
- ISSN
- 0161-7567 (ISSN-L)
- 8750-7587
- 1522-1601
- OpenAlex
- W2181273021
- Cited by
- 365
- References
- 10
- FWCI
- 8.57
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Validation of fluorescent-labeled microspheres for measurement of regional organ perfusion. https://app.cochat.ai/papers/10.1152/jappl.1993.74.5.2585
- The paper
- Glenny, R. W., Bernard, S., & Brinkley, M. (1993). Validation of fluorescent-labeled microspheres for measurement of regional organ perfusion. Journal of Applied Physiology. https://doi.org/10.1152/jappl.1993.74.5.2585
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.