Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 165

The DOI matches its Crossref record.

Transesophageal two-dimensional echocardiography and color Doppler flow velocity mapping in the evaluation of cardiac valve prostheses.

Nellessen, U, Schnittger, I, Appleton, C P, Masuyama, T, Bolger, A, Fischell, T A, Tye, T, Popp, R L·1988·Circulation

Abstract

To determine the value of transesophageal ultrasound in the assessment of cardiac valve prostheses, 14 patients with clinically suspected mitral prosthesis malfunction were studied by transthoracic and transesophageal two-dimensional imaging as well as by color Doppler flow velocity mapping (color Doppler). Patients underwent left ventricular angiography (n = 13), surgery (n = 11), or both angiography and surgery (n = 10). Nine patients had only mitral valve replacement, four patients had both mitral and aortic valve replacement, and one patient had mitral, aortic, and tricuspid valve replacement. There were 16 biological and four mechanical prostheses. The degree of mitral regurgitation was graded by both transthoracic and transesophageal color Doppler according to the area of the regurgitant jet visualized and was compared with a three-point classification of mitral regurgitation by left ventricular angiography judged by observers blinded to the echocardiographic results. All transesophageal studies were performed without complication and were well tolerated. The pathological morphology of the mitral prosthesis was additionally or more clearly visualized by transesophageal two-dimensional imaging and subsequently proven at surgery in three patients with flail leaflets and one patient with a vegetation compared with images obtained by the transthoracic approach. Valvular regurgitation was graded by the transthoracic approach as absent in four patients, mild in two patients, moderate in five patients, and severe in only three patients. The transesophageal assessment showed absence of mitral regurgitation in two patients, moderate regurgitation in two patients, and severe regurgitation in 10 patients.(ABSTRACT TRUNCATED AT 250 WORDS)

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1161/01.cir.78.4.848

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 165

Metadata

Authors
Nellessen, U., Schnittger, I., Appleton, C. P., Masuyama, T., Bolger, A., Fischell, T. A., Tye, T., & Popp, R. L.
Venue
Circulation
Published
1988-10
Volume
78
Issue
4
Pages
848-855
ISSN
  • 0009-7322 (ISSN-L)
  • 1524-4539
OpenAlex
W1994634441
Cited by
165
References
0
FWCI
17.37
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Transesophageal two-dimensional echocardiography and color Doppler flow velocity mapping in the evaluation of cardiac valve prostheses. https://app.cochat.ai/papers/10.1161/01.cir.78.4.848
The paper
Nellessen, U., Schnittger, I., Appleton, C. P., Masuyama, T., Bolger, A., Fischell, T. A., Tye, T., & Popp, R. L. (1988). Transesophageal two-dimensional echocardiography and color Doppler flow velocity mapping in the evaluation of cardiac valve prostheses. Circulation. https://doi.org/10.1161/01.cir.78.4.848

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.