The DOI matches its Crossref record; 29 of the 29 references it cites were found in a registry or an index.
Comparison of transthoracic and transesophageal echocardiography for detection of abnormalities of prosthetic and bioprosthetic valves in the mitral and aortic positions
Abstract
Two-dimensional echocardiography is the diagnostic procedure of choice for evaluation of prosthetic valve abnormalities. However, transthoracic echocardiography (TTE) may be limited owing to acoustic shadowing and poor acoustic windows. Some of these limitations may be overcome by transesophageal echocardiography (TEE). One hundred twenty-six patients with 148 prosthetic valves (113 bioprostheses and 35 mechanical devices) were studied by M-mode and 2-dimensional TTE and TEE. Prosthetic valve morphology was confirmed by surgery or autopsy in all cases; 124 prostheses were classified as diseased (33 endocarditis, 8 thrombi, and 83 degeneration defined as leaflet thickening > 3 mm with restricted motion) and 24 as normal. Prosthetic valve endocarditis and thrombi were correctly identified by TTE in 12 of 33 (36%) and 1 of 8 (13%) prostheses, respectively, but could be diagnosed by TEE in 27 of 33 (82%; p < 0.001) and 8 of 8 (100%; p < 0.01), respectively. Compared with TTE, TEE had a higher sensitivity for morphologic prosthetic valve abnormalities in patients with either bioprostheses (88 [87%] vs 66 [65%] of 101 prostheses; p < 0.01) or mechanical devices (19 [83%] vs 5 [22%] of 23 prostheses; p < 0.01) and in patients with a prosthesis in either the aortic (49 [77%] vs 32 [50%] of 64; p < 0.01) or mitral (58 [97%] vs 39 [65%] of 60; p < 0.001) position. Overall, sensitivity and specificity were 57 and 63%, respectively, for TTE, and 86 and 88%, respectively, for TEE.(ABSTRACT TRUNCATED AT 250 WORDS)
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“In the setting of a prosthetic valve, transthoracic images are greatly hampered by the structural components of the prosthesis and are inadequate for assessment of the perivalvular area where those infections often start.48”
Citations
Cites
Safety of transesophageal echocardiography. A multicenter survey of 10,419 examinations.
Daniel, W. G., Erbel, R., Kasper, W., Visser, C. A., Engberding, R., Sutherland, G. R., Grube, E., Hanrath, P., Maisch, B., & Dennig, K. (1991) · Circulation · doi:10.1161/01.cir.83.3.817 · Cited by 825
Self-citationSEWARD, J. B., KHANDHERIA, B. K., OH, J. K., ABEL, M. D., HUGHES, R. W., EDWARDS, W. D., NICHOLS, B. A., FREEMAN, W. K., & TAJIK, A. J. (1988) · Mayo Clinic Proceedings · doi:10.1016/s0025-6196(12)65529-3 · Cited by 791
Daniel, W. G., Mügge, A., Martin, R. P., Lindert, O., Hausmann, D., Nonnast-Daniel, B., Laas, J., & Lichtlen, P. R. (1991) · New England Journal of Medicine · doi:10.1056/nejm199103213241203 · Cited by 723
Self-citationMügge, A., Daniel, W. G., Frank, G., & Lichtlen, P. R. (1989) · Journal of the American College of Cardiology · doi:10.1016/0735-1097(89)90104-6 · Cited by 654
Self-citationFrazin, L., Talano, J. V., Stephanides, L., Loeb, H. S., Kopel, L., & Gunnar, R. M. (1976) · Circulation · doi:10.1161/01.cir.54.1.102 · Cited by 300
Schluter, M., Langenstein, B. A., Polster, J., Kremer, P., Souquet, J., Engel, S., & Hanrath, P. (1982) · Heart · doi:10.1136/hrt.48.1.67 · Cited by 168
Normal and abnormal prosthetic valve function as assessed by doppler echocardiography
Panidis, I. P., Ross, J., & Mintz, G. S. (1986) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(86)80046-8 · Cited by 165
Nellessen, U., Schnittger, I., Appleton, C. P., Masuyama, T., Bolger, A., Fischell, T. A., Tye, T., & Popp, R. L. (1988) · Circulation · doi:10.1161/01.cir.78.4.848 · Cited by 165
Value and limitations of transesophageal echocardiography in assessment of mitral valve prostheses.
Khandheria, B. K., Seward, J. B., Oh, J. K., Freeman, W. K., Nichols, B. A., Sinak, L. J., Miller, F. A., & Tajik, A. J. (1991) · Circulation · doi:10.1161/01.cir.83.6.1956 · Cited by 141
Doppler echocardiographic evaluation of Hancock and Björk-Shiley prosthetic valves
Sagar, K. B., Wann, L. S., Paulsen, W., & Romhilt, D. W. (1986) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(86)80480-6 · Cited by 119
Cited by
2014 AHA/ACC Guideline for the Management of Patients With Valvular Heart Disease
Nishimura, R. A., Otto, C. M., Bonow, R. O., Carabello, B. A., Erwin, J. P., Guyton, R. A., O’Gara, P. T., Ruiz, C. E., Skubas, N. J., Sorajja, P., et al. (2014) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2014.02.536 · Cited by 3,523
Baddour, L. M., Wilson, W. R., Bayer, A. S., Fowler, V. G., Tleyjeh, I. M., Rybak, M. J., Barsic, B., Lockhart, P. B., Gewitz, M. H., Levison, M. E., et al. (2015) · Circulation · doi:10.1161/cir.0000000000000296 · Cited by 3,232
“ment of the perivalvular area where those infections often start.(48) Although cost-effectiveness calculations suggest that”
BackgroundNishimura, R. A., Otto, C. M., Bonow, R. O., Carabello, B. A., Erwin, J. P., Guyton, R. A., O’Gara, P. T., Ruiz, C. E., Skubas, N. J., Sorajja, P., et al. (2014) · Circulation · doi:10.1161/cir.0000000000000031 · Cited by 2,905
Baddour, L. M., Wilson, W. R., Bayer, A. S., Fowler, V. G., Bolger, A. F., Levison, M. E., Ferrieri, P., Gerber, M. A., Tani, L. Y., Gewitz, M. H., et al. (2005) · Circulation · doi:10.1161/circulationaha.105.165564 · Cited by 1,707
2025 ESC/EACTS Guidelines for the management of valvular heart disease
Praz, F., Borger, M. A., Lanz, J., Marin-Cuartas, M., Abreu, A., Adamo, M., Ajmone Marsan, N., Barili, F., Bonaros, N., Cosyns, B., et al. (2025) · European Heart Journal · doi:10.1093/eurheartj/ehaf194 · Cited by 1,072
Metadata
- Authors
- Daniel, W. G., Mügge, A., Grote, J., Hausmann, D., Nikutta, P., Laas, J., Lichtlen, P. R., & Martin, R. P.
- Affiliations
- Emory University (US)
- Corresponding author
- Daniel, Werner G.
- Venue
- The American Journal of Cardiology
- Publisher
- Elsevier BV
- Published
- 1993-01
- Volume
- 71
- Issue
- 2
- Pages
- 210-215
- ISSN
- 0002-9149 (ISSN-L)
- OpenAlex
- W2121874306
- Cited by
- 306
- References
- 29
- Citations by year
- 2026: 4 · 2025: 11 · 2024: 10 · 2023: 5 · 2022: 4 · 2021: 6 · 2020: 6 · 2019: 6 · 2018: 7 · 2017: 4 · 2016: 16 · 2015: 5 · 2014: 9 · 2013: 8 · 2012: 7
- FWCI
- 6.64
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.elsevier.com/tdm/userlicense/1.0/ (tdm)
- Locations
- The American Journal of Cardiology (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Cardiac Valve Diseases and Treatments
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Infective Endocarditis Diagnosis and Management
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Congenital Heart Disease Studies
- Keywords
- transthoracic echocardiography, transesophageal echocardiography, bioprosthetic heart valves, mechanical heart valves, prosthetic valve endocarditis, prosthetic valve thrombosis, prosthetic valve degeneration, mitral valve prosthesis, aortic valve prosthesis, sensitivity and specificity, acoustic shadowing
- MeSH terms
- Aortic Valve, Bioprosthesis, Echocardiography, Endocarditis, Female, Heart Valve Prosthesis, Humans, Male, Middle Aged, Mitral Valve, Reoperation, Sensitivity and Specificity, Thrombosis, Prosthesis-Related Infections
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Comparison of transthoracic and transesophageal echocardiography for detection of abnormalities of prosthetic and bioprosthetic valves in the mitral and aortic positions. https://app.cochat.ai/papers/10.1016/0002-9149(93)90740-4
- The paper
- Daniel, W. G., Mügge, A., Grote, J., Hausmann, D., Nikutta, P., Laas, J., Lichtlen, P. R., & Martin, R. P. (1993). Comparison of transthoracic and transesophageal echocardiography for detection of abnormalities of prosthetic and bioprosthetic valves in the mitral and aortic positions. The American Journal of Cardiology. https://doi.org/10.1016/0002-9149(93)90740-4
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.