The DOI matches its Crossref record.
Flow-mediated and reflex changes in large peripheral artery tone in humans.
Abstract
Studies of peripheral blood vessels in humans have focused primarily on regulation of blood flow and vascular resistance, which are thought to reflect small vessel caliber. Recent studies in animals have identified flow-mediated and neurogenic changes in large artery diameter. This study tested for flow-mediated dilatation and reflex constriction of the brachial artery in humans. A dual-crystal pulsed Doppler system was used to measure brachial artery diameter and blood flow proximal to the antecubital fossa. To test for flow-mediated dilatation, flow through the brachial artery was altered by an occluding cuff placed on the forearm distal to the site of brachial artery flow and diameter measurement. Control blood flow was 123 +/- 20 ml/min, and brachial artery diameter was 4.74 +/- 0.17 mm (mean +/- SEM). By inflating the distal occluding cuff (distal circulatory arrest), flow was reduced through the brachial artery to 21 +/- 5 ml/min (p less than 0.005), and brachial artery diameter was reduced to 4.35 +/- 0.20 mm (p less than 0.001). By deflating the distal occluding cuff after 10 minutes (reactive hyperemia), brachial artery flow was increased to 358 +/- 55 ml/min (p less than 0.001), and diameter was increased to 5.6 +/- 0.19 mm (p less than 0.001). These interventions did not change systemic arterial pressure and, as measured in three subjects, caused only small changes in local brachial artery distending pressure. Thus, both increased and decreased brachial artery blood flow produced significant changes in brachial artery diameter without altering arterial distending pressure. These data provide evidence for flow-mediated dilatation in humans.(ABSTRACT TRUNCATED AT 250 WORDS)
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Non-invasive detection of endothelial dysfunction in children and adults at risk of atherosclerosis
Celermajer, D. S., Sorensen, K. E., Gooch, V. M., Spiegelhalter, D. J., Miller, O. I., Sullivan, I. D., Lloyd, J. K., & Deanfield, J. E. (1992) · The Lancet · doi:10.1016/0140-6736(92)93147-f · Cited by 4,742
Vascular Adaptation to Exercise in Humans: Role of Hemodynamic Stimuli
Green, D. J., Hopman, M. T. E., Padilla, J., Laughlin, M. H., & Thijssen, D. H. J. (2017) · Physiological Reviews · doi:10.1152/physrev.00014.2016 · Cited by 821
Effects of exercise on vascular function, structure, and health in humans
Green, D. J., & Smith, K. J. (2018) · Cold Spring Harbor Perspectives in Medicine · doi:10.1101/cshperspect.a029819 · Cited by 197
Joannides, R., Costentin, A., Iacob, M., Compagnon, P., Lahary, A., & Thuillez, C. (2002) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.00209.2001 · Cited by 75
(2005) · doi:10.1111/j.1743-6109.2005.00098_1.x · Cited by 31
Metadata
- Authors
- Anderson, E. A., & Mark, A. L.
- Venue
- Circulation
- Published
- 1989-01
- Volume
- 79
- Issue
- 1
- Pages
- 93-100
- ISSN
- 0009-7322 (ISSN-L)
- 1524-4539
- OpenAlex
- W1977527401
- Cited by
- 274
- References
- 0
- FWCI
- 3.15
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.