Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 244

The DOI matches its Crossref record.

Stress-shortening relations and myocardial blood flow in compensated and failing canine hearts with pressure-overload hypertrophy.

Gaasch, W H, Zile, M R, Hoshino, P K, Apstein, C S, Blaustein, A S·1989·Circulation

Abstract

Serial changes in left ventricular (LV) size and function during the adaptation to chronic pressure overload and the transition to pump failure were studied in 16 conscious dogs (aortic bands placed at 8 weeks of age). Echocardiographic data at baseline and at 3, 6, 9, and 12 months after banding revealed a progressive increase in LV mass in all dogs. In six dogs with LV pump failure, there was a progressive decline in circumferential fiber shortening (29 +/- 4% at 12 months); this was significantly less than that seen in five littermate controls (38 +/- 3%, p less than 0.05). The average LV to body weight ratio in this group was 9.8 +/- 2.7 g/kg. In 10 dogs without pump failure (compensated LVH group), shortening exceeded that seen in the controls (43 +/- 4%, p less than 0.05); the LV to body weight ratio was 7.7 +/- 1.0 g/kg. At 12 months (cardiac catheterization), the LV end-diastolic pressure was higher in the failure (25 +/- 15 mm Hg) than in the compensated group (8 +/- 5 mm Hg, p less than 0.05); mean systolic stress was also higher in the failure group (313 +/- 67 g/cm2) than in the compensated group (202 +/- 53 g/cm2, p less than 0.05). The transmural distribution of myocardial blood flow was measured (at 12 months) with the radioactive microsphere technique; flow data were then related to an index of demand (a stress-time index). There was preferential blood flow to the subendocardial layers in the control (endo/epi = 1.28) and compensated hearts (endo/epi = 1.10), but in the failure group there was a relative decrease in subendocardial flow (endo/epi = 0.92). However, the absolute values for subendocardial flow in the normal, compensated, and failure groups were 77 +/- 54, 125 +/- 48, and 113 +/- 64 ml/min/100 g; the stress-time indexes in the subendocardial shell were 38 +/- 11, 74 +/- 19, and 93 +/- 34 g sec.10(2)/cm2/min. Despite what appears to be a marginal balance between blood flow and the stress time index in the failure group, the myocardial high energy phosphates were not depleted and the inoptropic state was not depressed. In this model of LV hypertrophy, the observed differences in fiber shortening can be explained on the basis of the inverse afterload-shortening relation; pump failure was due to an inadequate LV hypertrophy with afterload excess.(ABSTRACT TRUNCATED AT 400 WORDS)

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1161/01.cir.79.4.872

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 244

Metadata

Authors
Gaasch, W. H., Zile, M. R., Hoshino, P. K., Apstein, C. S., & Blaustein, A. S.
Venue
Circulation
Published
1989-04
Volume
79
Issue
4
Pages
872-883
ISSN
  • 0009-7322 (ISSN-L)
  • 1524-4539
OpenAlex
W2033120253
Cited by
244
References
0
FWCI
4.20
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Stress-shortening relations and myocardial blood flow in compensated and failing canine hearts with pressure-overload hypertrophy. https://app.cochat.ai/papers/10.1161/01.cir.79.4.872
The paper
Gaasch, W. H., Zile, M. R., Hoshino, P. K., Apstein, C. S., & Blaustein, A. S. (1989). Stress-shortening relations and myocardial blood flow in compensated and failing canine hearts with pressure-overload hypertrophy. Circulation. https://doi.org/10.1161/01.cir.79.4.872

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.