Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 169

The DOI matches its Crossref record.

Effects of volume loading during experimental acute pulmonary embolism.

Open access
Belenkie, I, Dani, R, Smith, E R, Tyberg, J V·1989·Circulation

Abstract

Volume loading is used to treat hemodynamically compromised patients with acute pulmonary embolism despite data to suggest that volume loading after embolism might cause a leftward shift of the ventricular septum with a subsequent decrease in left ventricular (LV) end-diastolic volume and stroke work. We studied 10 closed-chest, anesthetized, and ventilated dogs to assess the effects of volume loading after pulmonary embolism caused by autologous clot. LV, right ventricular, and right atrial pressures as well as LV anteroposterior, septum-to-right ventricular, and septum-to-LV free wall diameters (sonomicrometry) were measured. Pericardial pressure was measured with flat, liquid-containing balloons. The effects of volume loading were assessed before embolism, after one episode of embolization, and after repeated embolizations. The LV area index (as a reflection of LV volume) increased during volume loading before embolism (2,870 +/- 430 to 3,080 +/- 520 mm2; p less than 0.05), did not change significantly during infusion of fluid after one embolization (2,850 +/- 470 to 2,860 +/- 500 mm2; p = NS), and decreased significantly during volume expansion after repeated embolizations (2,760 +/- 440 to 2,660 +/- 420 mm2; p less than 0.01). An index of LV stroke work increased (188 +/- 85 to 260 +/- 101 mm Hg x mm2; p less than 0.05), did not change significantly (188 +/- 39 to 203 +/- 52 mm Hg x mm2; p = NS), and decreased markedly (133 +/- 64 to 45 +/- 27 mm Hg x mm2; p less than 0.001) before embolism, after one embolization, and after repeated embolizations, respectively. The decrease in LV area index during volume loading after repeated embolizations was associated with an increase in septum-to-right ventricular free wall diameter (31 +/- 8 to 34 +/- 8 mm; p = 0.001) and a decrease in the septum-to-LV free wall diameter (44 +/- 5 to 42 +/- 5 mm; p less than 0.001), whereas the LV anteroposterior diameter did not change (62 +/- 5 to 63 +/- 5 mm; p = NS). This is compatible with a leftward septal shift being partially responsible for the decrease in LV end-diastolic volume; such a shift would be expected with the observed decrease in transseptal end-diastolic pressure gradient (-3 +/- 2 to -5 +/- 2 mm Hg; p = 0.001). In addition, after repeated embolizations, LV transmural pressure decreased in response to the volume load reflecting a marked increase in pericardial pressure.(ABSTRACT TRUNCATED AT 400 WORDS)

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1161/01.cir.80.1.178

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 169

Metadata

Authors
Belenkie, I., Dani, R., Smith, E. R., & Tyberg, J. V.
Venue
Circulation
Published
1989-07
Volume
80
Issue
1
Pages
178-188
ISSN
  • 0009-7322 (ISSN-L)
  • 1524-4539
OpenAlex
W2095498955
Cited by
169
References
0
FWCI
4.02
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Effects of volume loading during experimental acute pulmonary embolism. https://app.cochat.ai/papers/10.1161/01.cir.80.1.178
The paper
Belenkie, I., Dani, R., Smith, E. R., & Tyberg, J. V. (1989). Effects of volume loading during experimental acute pulmonary embolism. Circulation. https://doi.org/10.1161/01.cir.80.1.178

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.