Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 381

The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.

Decreased magnitude of heart rate spectral components in coronary artery disease. Its relation to angiographic severity.

Open access
Hayano, J, Sakakibara, Y, Yamada, M, Ohte, N, Fujinami, T, Yokoyama, K, Watanabe, Y, Takata, K·1990·Circulation

Abstract

We analyzed the spectral components of RR interval variability under controlled respiration (15 breaths/min) in 56 patients (age range, 35-73 years) referred for coronary angiography; 14 patients had multivessel disease (group M), 21 had one-vessel disease (group S), and 21 had nonsignificant disease or normal coronary artery (group N). There were 43 healthy controls (age range, 36-71 years) (group C). The patients had no clinical evidence of heart failure, hypertension, diabetes mellitus, or acute stage of infarction and had taken no medication for 3 days. The autoregressive power spectral density of RR interval variability contains two major components, respiratory sinus arrhythmia (RSA) (0.25 Hz) and Mayer wave-like sinus arrhythmia (MWSA) (0.04-0.15 Hz), which have magnitudes that are quantitative markers of cardiac vagal activity and sympathetic activity with vagal modulation, respectively. We represented the magnitudes by the coefficient of component variance (CCV), which provided the amplitude relative to the mean RR interval. The age- and sex-adjusted mean of CCVRSA significantly decreased with advancing angiographic severity (1.64 +/- 0.09%, 1.66 +/- 0.12%, 1.22 +/- 0.13%, and 0.81 +/- 0.16% for groups C, N, S, and M, respectively) (p = 0.0001). The CCVRSA was unrelated to left ventricular function, previous myocardial infarction, or stenosis of any specific artery including the sinoatrial and atrioventricular node arteries. The CCVMWSA decreased only in group M (p = 0.0462). These results indicate that coronary artery disease is associated with vagal dominant impairment in autonomic cardiac function and that reduction in the vagal cardiac function correlates with the angiographic severity.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1161/01.cir.81.4.1217

Cites

4 of 4 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 4 references

Cited by

See all 381

Metadata

Authors
Hayano, J., Sakakibara, Y., Yamada, M., Ohte, N., Fujinami, T., Yokoyama, K., Watanabe, Y., & Takata, K.
Venue
Circulation
Published
1990-04
Volume
81
Issue
4
Pages
1217-1224
ISSN
  • 0009-7322 (ISSN-L)
  • 1524-4539
OpenAlex
W2045490095
Cited by
381
References
4
FWCI
14.31
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Decreased magnitude of heart rate spectral components in coronary artery disease. Its relation to angiographic severity. https://app.cochat.ai/papers/10.1161/01.cir.81.4.1217
The paper
Hayano, J., Sakakibara, Y., Yamada, M., Ohte, N., Fujinami, T., Yokoyama, K., Watanabe, Y., & Takata, K. (1990). Decreased magnitude of heart rate spectral components in coronary artery disease. Its relation to angiographic severity. Circulation. https://doi.org/10.1161/01.cir.81.4.1217

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.