The DOI matches its Crossref record.
Electrophysiological testing and nonsustained ventricular tachycardia. Use and limitations in patients with coronary artery disease and impaired ventricular function.
Open accessAbstract
Electrophysiological testing was performed in 100 consecutive patients with spontaneous asymptomatic nonsustained ventricular tachycardia, chronic coronary artery disease, and ejection fraction of less than 40%. Fifty-seven patients without inducible sustained ventricular arrhythmias were discharged on no antiarrhythmic therapy. Sustained monomorphic ventricular tachycardia was induced in 37 patients, and polymorphic ventricular tachycardia or ventricular fibrillation was induced in six patients. Of the 43 patients with inducible sustained ventricular arrhythmias, three had spontaneous cardiac arrest during serial drug testing and were excluded from further analysis. Twenty patients were discharged on drug therapy, resulting in suppression of inducible sustained ventricular arrhythmias. The remaining 20 patients with persistently inducible sustained arrhythmias were discharged on drug therapy, resulting in maximal rate slowing of the induced tachycardia. During a mean follow-up of 16.7 months, there were 10 recurrent cardiac arrests or sudden deaths. The 1- and 2-year actuarial incidence of these events was 2% and 6%, respectively, in patients without inducible sustained ventricular arrhythmias; 0% and 11%, respectively, in patients in whom inducible arrhythmias were suppressed; and 34% and 50%, respectively, in patients with persistently inducible sustained ventricular arrhythmias. Multivariate Cox analysis identified only the persistence of inducible sustained ventricular arrhythmias as a significant independent predictor of sudden death or recurrent sustained arrhythmias (p less than 0.001; relative risk, 3.5; 95% confidence intervals, 2.1-4.9). In this population, therapeutic intervention to prevent sudden death is unnecessary in patients without inducible sustained ventricular arrhythmias.(ABSTRACT TRUNCATED AT 250 WORDS)
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Moss, A. J., Hall, W. J., Cannom, D. S., Daubert, J. P., Higgins, S. L., Klein, H., Levine, J. H., Saksena, S., Waldo, A. L., Wilber, D., et al. (1996) · New England Journal of Medicine · doi:10.1056/nejm199612263352601 · Cited by 4,165
Self-citationA Randomized Study of the Prevention of Sudden Death in Patients with Coronary Artery Disease
Buxton, A. E., Lee, K. L., Fisher, J. D., Josephson, M. E., Prystowsky, E. N., & Hafley, G. (1999) · New England Journal of Medicine · doi:10.1056/nejm199912163412503 · Cited by 2,489
Zipes, D. P., Camm, A. J., Borggrefe, M., Buxton, A. E., Chaitman, B., Fromer, M., Gregoratos, G., Klein, G., Moss, A. J., Myerburg, R. J., et al. (2006) · Circulation · doi:10.1161/circulationaha.106.178233 · Cited by 1,080
Syncope in advanced heart failure: high risk of sudden death regardless of origin of syncope
Middlekauff, H. R., Stevenson, W. G., Stevenson, L. W., & Saxon, L. A. (1993) · Journal of the American College of Cardiology · doi:10.1016/0735-1097(93)90724-f · Cited by 311
Implantable Cardioverter-Defibrillators: Expanding Indications and Technologies
Goldberger, Z., & Lampert, R. (2006) · JAMA · doi:10.1001/jama.295.7.809 · Cited by 271
Pires, L. A., Lehmann, M. H., Buxton, A. E., Hafley, G. E., & Lee, K. L. (2001) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(01)01482-6 · Cited by 42
Metadata
- Authors
- Wilber, D. J., Olshansky, B., Moran, J. F., & Scanlon, P. J.
- Venue
- Circulation
- Published
- 1990-08
- Volume
- 82
- Issue
- 2
- Pages
- 350-358
- ISSN
- 0009-7322 (ISSN-L)
- 1524-4539
- OpenAlex
- W2025474211
- Cited by
- 274
- References
- 0
- FWCI
- 18.35
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.