Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 188

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Prognostic value of electrophysiology testing in asymptomatic patients with Wolff-Parkinson-White pattern.

Open access
Leitch, J W, Klein, G J, Yee, R, Murdock, C · 1990 · Circulation

Abstract

The prognostic value of electrophysiology testing was studied in 75 asymptomatic patients with the Wolff-Parkinson-White electrocardiographic pattern. All patients underwent electrophysiology testing at entry to the study and were followed up annually for a total of 348 patient-years (median, 4.3 years). There were 44 male and 31 female patients, and age at enrollment ranged from 7 to 77 years (mean, 34 +/- 14 years). The median effective refractory period of the accessory pathway was 293 msec (interquartile range, 280-310 msec), and the median shortest RR interval between preexcited beats during atrial fibrillation (SRR) [corrected] was 274 msec (240-320 msec). Twenty-three patients had an SRR of 250 msec or less and eight patients had a median shortest SRR interval of 200 msec or less. Twelve patients had inducible sustained reciprocating tachycardia, 10 patients had inducible nonsustained reciprocating tachycardia, and 23 patients had inducible sustained atrial fibrillation. Twenty patients (27%) lacked retrograde conduction over the accessory pathway. No patient died suddenly during a median follow-up of 4.3 years. Six patients (8%) became symptomatic with documented supraventricular tachycardia, of whom two underwent operative ablation of their accessory pathways. No patient with absent retrograde accessory pathway conduction during the electrophysiology study became symptomatic. Inducible sustained or nonsustained reciprocating tachycardia at electrophysiology study did not predict the development of subsequent symptomatic supraventricular tachycardia. Nine patients lost preexcitation during follow-up. Age at enrollment (relative risk/decade, 1.4; 95% confidence interval, 1.0-1.8) and anterograde accessory pathway refractory period (relative risk, 1.06/10 msec; 95% confidence interval, 1.0-1.12) were independent predictors of loss of preexcitation.(ABSTRACT TRUNCATED AT 250 WORDS)

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1161/01.cir.82.5.1718

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

See all 188

Metadata

Authors
Leitch, J. W., Klein, G. J., Yee, R., & Murdock, C.
Venue
Circulation
Published
1990-11
Volume
82
Issue
5
Pages
1718-1723
ISSN
  • 0009-7322 (ISSN-L)
  • 1524-4539
OpenAlex
W1962756042
Cited by
188
References
1
FWCI
4.04
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Prognostic value of electrophysiology testing in asymptomatic patients with Wolff-Parkinson-White pattern. https://app.cochat.ai/papers/10.1161/01.cir.82.5.1718
The paper
Leitch, J. W., Klein, G. J., Yee, R., & Murdock, C. (1990). Prognostic value of electrophysiology testing in asymptomatic patients with Wolff-Parkinson-White pattern. Circulation. https://doi.org/10.1161/01.cir.82.5.1718

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.