The DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.
Safety of transesophageal echocardiography. A multicenter survey of 10,419 examinations.
Abstract
BACKGROUND: During the past few years, transesophageal echocardiography (TEE) has been increasingly used in clinical cardiology; data concerning the practicability and safety of the technique, however, are rare. METHODS AND RESULTS: This report analyzes the experience of 15 European centers performing TEE studies for at least 1 year. At the time of this survey, 10,419 TEE examinations had been attempted or performed in these institutions. These TEE examinations were carried out by 54 physicians, 53.7% of whom had been trained in endoscopic techniques. Within the same time period, 160,431 precordial echocardiographic examinations were performed in the 15 institutions; the ratio between TEE and transthoracic studies averaged 9.03 +/- 6.4% (range of the 15 centers, 1.4-23.6%). Of the 10,419 patients, 9,240 (88.7%) were conscious inpatients or outpatients at the time of the TEE examination; the vast majority of the conscious patients did not receive intravenous sedation before TEE. In 201 cases (1.9%), insertion of the TEE probe was unsuccessfully attempted because of a lack of patient cooperation and/or operator experience (98.5%) or because of anatomical reasons (1.5%). In 90 of 10,218 TEE studies (0.88%) with successful probe insertion, the examination had to be interrupted because of the patient's intolerance of the echoscope (65 cases); because of pulmonary (eight cases), cardiac (eight cases), or bleeding complications (two cases); or for other reasons (seven cases). One of the bleeding complications resulted from a malignant lung tumor with esophageal infiltration and was fatal (mortality rate, 0.0098%). CONCLUSIONS: This multicenter survey documents that TEE studies are associated with an acceptable low risk when used by experienced operators under proper safety conditions.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
SEWARD, J. B., KHANDHERIA, B. K., OH, J. K., ABEL, M. D., HUGHES, R. W., EDWARDS, W. D., NICHOLS, B. A., FREEMAN, W. K., & TAJIK, A. J. (1988) · Mayo Clinic Proceedings · doi:10.1016/s0025-6196(12)65529-3 · Cited by 791
SEWARD, J. B., KHANDHERIA, B. K., EDWARDS, W. D., OH, J. K., FREEMAN, W. K., & TAJIK, A. J. (1990) · Mayo Clinic Proceedings · doi:10.1016/s0025-6196(12)62744-x · Cited by 320
Risk of transesophageal echocardiography in awake patients with cardiac diseases
Geibel, A., Kasper, W. E., Behroz, A., Przewolka, U., Meinertz, T., & Just, H. (1988) · The American Journal of Cardiology · doi:10.1016/0002-9149(88)90244-5 · Cited by 75
Self-citationStreptococcal Endocarditis Temporally Related to Transesophageal Echocardiography
Foster, E., Kusumoto, F. M., Sobol, S. M., & Schiller, N. B. (1990) · Journal of the American Society of Echocardiography · doi:10.1016/s0894-7317(14)80145-4 · Cited by 55
Positive blood cultures during transesophageal echocardiography
Görge, G., Erbel, R. M., Henrichs, K. J., Wenchel, H.-M., Werner, H.-P., & Meyer, J. (1990) · The American Journal of Cardiology · doi:10.1016/0002-9149(90)91338-7 · Cited by 45
Self-citationPracticability of Transesophageal Echocardiography in Conscious Patients
Daniel, W. G., Mügge, A., Eschenbruch, C., & Lichtlen, P. R. (1989) · Springer eBooks · doi:10.1007/978-3-642-74257-6_45 · Cited by 8
Self-citation
Cited by
Durack, D. T., Lukes, A. S., Bright, D. K., & Service, D. E. (1994) · The American Journal of Medicine · doi:10.1016/0002-9343(94)90143-0 · Cited by 2,572
WRITING GROUP MEMBERS, Hiratzka, L. F., Bakris, G. L., Beckman, J. A., Bersin, R. M., Carr, V. F., Casey, D. E., Eagle, K. A., Hermann, L. K., Isselbacher, E. M., et al. (2010) · Circulation · doi:10.1161/cir.0b013e3181d4739e · Cited by 2,289
Hiratzka, L. F., Bakris, G. L., Beckman, J. A., Bersin, R. M., Carr, V. F., Casey, D. E., Eagle, K. A., Hermann, L. K., Isselbacher, E. M., Kazerooni, E. A., et al. (2010) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2010.02.015 · Cited by 1,692
Hahn, R. T., Abraham, T., Adams, M. S., Bruce, C. J., Glas, K. E., Lang, R. M., Reeves, S. T., Shanewise, J. S., Siu, S. C., Stewart, W., et al. (2013) · Journal of the American Society of Echocardiography · doi:10.1016/j.echo.2013.07.009 · Cited by 1,351
Diagnosis and Management of Infective Endocarditis and Its Complications
Bayer, A. S., Bolger, A. F., Taubert, K. A., Wilson, W., Steckelberg, J., Karchmer, A. W., Levison, M., Chambers, H. F., Dajani, A. S., Gewitz, M. H., et al. (1998) · Circulation · doi:10.1161/01.cir.98.25.2936 · Cited by 759
Shanewise, J. S., Cheung, A. T., Aronson, S., Stewart, W. J., Weiss, R. L., Mark, J. B., Savage, R. M., Sears-Rogan, P., Mathew, J. P., Quiñones, M. A., et al. (1999) · Journal of the American Society of Echocardiography · doi:10.1016/s0894-7317(99)70199-9 · Cited by 728
Daniel, W. G., Mügge, A., Martin, R. P., Lindert, O., Hausmann, D., Nonnast-Daniel, B., Laas, J., & Lichtlen, P. R. (1991) · New England Journal of Medicine · doi:10.1056/nejm199103213241203 · Cited by 723
Self-citationTzeis, S., Gerstenfeld, E. P., Kalman, J., Saad, E. B., Sepehri Shamloo, A., Andrade, J. G., Barbhaiya, C. R., Baykaner, T., Boveda, S., Calkins, H., et al. (2024) · Europace · doi:10.1093/europace/euae043 · Cited by 634
Safety of Transesophageal Echocardiography
Hilberath, J. N., Oakes, D. A., Shernan, S. K., Bulwer, B. E., D’Ambra, M. N., & Eltzschig, H. K. (2010) · Journal of the American Society of Echocardiography · doi:10.1016/j.echo.2010.08.013 · Cited by 612
Chartier, L., Béra, J., Delomez, M., Asseman, P., Beregi, J.-P., Bauchart, J.-J., Warembourg, H., & Théry, C. (1999) · Circulation · doi:10.1161/01.cir.99.21.2779 · Cited by 476
Manning, W. J., Silverman, D. I., Gordon, S., Krumholz, H. M., & Douglas, P. S. (1993) · New England Journal of Medicine · doi:10.1056/nejm199303183281102 · Cited by 330
Manning, W. J., Silverman, D. I., Keighley, C. S., Oettgen, P., & Douglas, P. S. (1995) · Journal of the American College of Cardiology · doi:10.1016/0735-1097(94)00560-d · Cited by 324
Daniel, W. G., Mügge, A., Grote, J., Hausmann, D., Nikutta, P., Laas, J., Lichtlen, P. R., & Martin, R. P. (1993) · The American Journal of Cardiology · doi:10.1016/0002-9149(93)90740-4 · Cited by 306
Self-citationHausmann, D., Mügge, A., Becht, I., & Daniel, W. G. (1992) · The American Journal of Cardiology · doi:10.1016/0002-9149(92)90210-p · Cited by 303
Self-citationTzeis, S., Gerstenfeld, E. P., Kalman, J., Saad, E. B., Shamloo, A. S., Andrade, J. G., Barbhaiya, C. R., Baykaner, T., Boveda, S., Calkins, H., et al. (2024) · Heart Rhythm · doi:10.1016/j.hrthm.2024.03.017 · Cited by 298
Aortic Atherosclerotic Disease and Stroke
Kronzon, I., & Tunick, P. A. (2006) · Circulation · doi:10.1161/circulationaha.105.593418 · Cited by 296
Quiñones, M. A., Douglas, P. S., Foster, E., Gorcsan, J., Lewis, J. F., Pearlman, A. S., Rychik, J., Salcedo, E. E., Seward, J. B., Stevenson, J. G., et al. (2003) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(02)02885-1 · Cited by 281
Vignon, P., Mentec, H., Terré, S., Gastinne, H., Guéret, P., & Lemaire, F. (1994) · Chest · doi:10.1378/chest.106.6.1829 · Cited by 269
Intraoperative transesophageal echocardiography during surgery for congenital heart defects
Randolph, G. R., Hagler, D. J., Connolly, H. M., Dearani, J. A., Puga, F. J., Danielson, G. K., Abel, M. D., Pankratz, V. S., & O'Leary, P. W. (2002) · The Journal of Thoracic and Cardiovascular Surgery · doi:10.1067/mtc.2002.125816 · Cited by 141
Echocardiography in patients with suspected endocarditis: a cost-effectiveness analysis
Heidenreich, P. A., Masoudi, F. A., Maini, B., Chou, T. M., Foster, E., Schiller, N. B., & Owens, D. K. (1999) · The American Journal of Medicine · doi:10.1016/s0002-9343(99)00216-8 · Cited by 119
Endocarditis-Associated Paravalvular Abscesses
Blumberg, E. A., Karalis, D. A., Chandrasekaran, K., Wahl, J. M., Vilaro, J., Covalesky, V. A., & Mintz, G. S. (1995) · Chest · doi:10.1378/chest.107.4.898 · Cited by 114
on behalf of the GAME Study Group (Grupo de Apoyo al Manejo de la Endocarditis), Fernández-Cruz, A., Cruz Menárguez, M., Muñoz, P., Pedromingo, M., Peláez, T., Solís, J., Rodríguez-Créixems, M., & Bouza, E. (2015) · European Journal of Clinical Microbiology & Infectious Diseases · doi:10.1007/s10096-015-2384-z · Cited by 58
Intraoperative transesophageal echocardiography in congenital heart disease
Smallhorn, J. F. (2002) · Echocardiography · doi:10.1046/j.1540-8175.2002.00709.x · Cited by 33
Metadata
- Authors
- Daniel, W. G., Erbel, R., Kasper, W., Visser, C. A., Engberding, R., Sutherland, G. R., Grube, E., Hanrath, P., Maisch, B., & Dennig, K.
- Venue
- Circulation
- Published
- 1991-03
- Volume
- 83
- Issue
- 3
- Pages
- 817-821
- ISSN
- 0009-7322 (ISSN-L)
- 1524-4539
- OpenAlex
- W2051968895
- Cited by
- 825
- References
- 6
- FWCI
- 33.32
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.