Measurement of regional myocardial blood flow with multiple colored microspheres.
Open accessAbstract
BACKGROUND: The use of radioactive microspheres (RM) for the measurement of regional myocardial blood flow (RMBF) is limited and inaccessible to many investigators due to radiation safety concerns and radioactive waste disposal problems. Therefore, a new method for the measurement of RMBF using colored microspheres (CM) was developed. METHODS AND RESULTS: Polystyrene spheres (diameter, 15 +/- 0.1 [SD] micron; density, 1.09 g/ml) were dyed with one of five colors. With the injection of CM into the left atrium or into a coronary perfusion line, RMBF and its distribution can be determined. CM are extracted from the myocardium and blood by digestion with potassium hydroxide and subsequent microfiltration. The dyes are then recovered from the CM within a defined volume of a solvent, and their concentrations are determined by spectrophotometry. The separation of composite absorbance spectra by spectrophotometry with the CM technique was as good as the separation of energy spectra by a gamma-counter using the RM technique. Leaching of dye from the CM was less than 0.1% during a 2-month period in vitro. Significant leaching of dye from the microspheres also did not occur during 8 hours in the blood and myocardium of four anesthetized dogs in vivo. For further validation of this method, pairs of CM and RM (15.5 +/- 0.1 [SD] microns) were simultaneously injected under five different RMBF conditions (range, 0-10 ml/[min.g]) into the left anterior descending coronary artery of four anesthetized pigs, with coronary inflow as a flow reference, or into the left atrium of four anesthetized dogs using aortic blood withdrawal as a reference. The relation between RMBF determined by CM and RM was CM = 0.01 + 1.00.RM (r = 0.98, n = 1,080 data points) in the pigs, and CM = -0.19 + 0.92.RM (r = 0.97, n = 1,813 data points) in the dogs. CONCLUSIONS: Measurement of RMBF with CM yields values very similar to those of RM. Their use is less expensive and avoids all the disadvantages related to radioactivity, thus offering an alternative method for as many as five RMBF measurements in a single experiment.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Guidelines for experimental models of myocardial ischemia and infarction
Lindsey, M. L., Bolli, R., Canty, J. M., Du, X.-J., Frangogiannis, N. G., Frantz, S., Gourdie, R. G., Holmes, J. W., Jones, S. P., Kloner, R. A., et al. (2018) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.00335.2017 · Cited by 526
Self-citationValidation of fluorescent-labeled microspheres for measurement of regional organ perfusion
Glenny, R. W., Bernard, S., & Brinkley, M. (1993) · Journal of Applied Physiology · doi:10.1152/jappl.1993.74.5.2585 · Cited by 365
Coronary circulation in dogs with an experimental decrease in aortic compliance
Watanabe, H., Ohtsuka, S., Kakihana, M., & Sugishita, Y. (1993) · Journal of the American College of Cardiology · doi:10.1016/0735-1097(93)90330-4 · Cited by 278
Metadata
- Authors
- Kowallik, P., Schulz, R., Guth, B. D., Schade, A., Paffhausen, W., Gross, R., & Heusch, G.
- Venue
- Circulation
- Published
- 1991-03
- Volume
- 83
- Issue
- 3
- Pages
- 974-982
- ISSN
- 0009-7322 (ISSN-L)
- 1524-4539
- OpenAlex
- W2087461041
- Cited by
- 375
- References
- 0
- FWCI
- 9.99
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Measurement of regional myocardial blood flow with multiple colored microspheres. https://app.cochat.ai/papers/10.1161/01.cir.83.3.974
- The paper
- Kowallik, P., Schulz, R., Guth, B. D., Schade, A., Paffhausen, W., Gross, R., & Heusch, G. (1991). Measurement of regional myocardial blood flow with multiple colored microspheres. Circulation. https://doi.org/10.1161/01.cir.83.3.974
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.