Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 292

The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.

Percutaneous balloon versus surgical closed commissurotomy for mitral stenosis. A prospective, randomized trial.

Turi, Z G, Reyes, V P, Raju, B S, Raju, A R, Kumar, D N, Rajagopal, P, Sathyanarayana, P V, Rao, D P, Srinath, K, Peters, P·1991·Circulation

Abstract

BACKGROUND: We performed a prospective, randomized trial comparing percutaneous balloon commissurotomy with surgical closed commissurotomy in 40 patients with severe rheumatic mitral stenosis. METHODS AND RESULTS: Data were analyzed by investigators who were masked to treatment assignment or phase of study. Patients randomized to balloon (n = 20) or surgical (n = 20) commissurotomy had severe mitral stenosis without significant baseline differences (left atrial pressure, 26.1 +/- 4.2 versus 27.6 +/- 6.2 mm Hg; mitral valve gradient, 18.0 +/- 4.2 versus 19.7 +/- 6.3 mm Hg; mitral valve area, 1.0 +/- 0.2 versus 1.0 +/- 0.4 cm2, respectively). At 1-week follow-up after balloon commissurotomy, pulmonary wedge pressure was 14.3 +/- 7.2 mm Hg; mitral valve gradient was 9.6 +/- 5.1 mm Hg; and mitral valve area was 1.6 +/- 0.6 cm2 (all p less than 0.0001). At 1-week follow-up after surgical closed commissurotomy, wedge pressure was 13.7 +/- 5.4 mm Hg; mitral valve gradient was 9.4 +/- 4.2 mm Hg (both p less than 0.0001); and mitral valve area was 1.6 +/- 0.7 cm2 (p less than 0.003). At 8-month follow-up, improvement occurred in both groups: Mitral valve area was 1.6 +/- 0.6 cm2 in the balloon commissurotomy group (p less than 0.002) and was 1.8 +/- 0.6 cm2 in the surgical closed commissurotomy group (p less than 0.0001). There was no difference between the groups at 1-week or 8-month follow-up (all p greater than 0.4). One case of severe mitral regurgitation occurred in each group; complications were otherwise related to transseptal catheterization. There was no death, stroke, or myocardial infarction. Cost analysis revealed that balloon commissurotomy may substantially exceed the cost of surgical commissurotomy in developing countries, whereas it may represent a significant savings in industrialized nations. CONCLUSIONS: We conclude that percutaneous balloon commissurotomy and surgical closed commissurotomy result in comparable hemodynamic improvement that is sustained through 8 months of follow-up.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1161/01.cir.83.4.1179

Cites

4 of 4 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 4 references

Cited by

See all 292

Metadata

Authors
Turi, Z. G., Reyes, V. P., Raju, B. S., Raju, A. R., Kumar, D. N., Rajagopal, P., Sathyanarayana, P. V., Rao, D. P., Srinath, K., & Peters, P.
Venue
Circulation
Published
1991-04
Volume
83
Issue
4
Pages
1179-1185
ISSN
  • 0009-7322 (ISSN-L)
  • 1524-4539
OpenAlex
W2025920836
Cited by
292
References
4
FWCI
13.60
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Percutaneous balloon versus surgical closed commissurotomy for mitral stenosis. A prospective, randomized trial. https://app.cochat.ai/papers/10.1161/01.cir.83.4.1179
The paper
Turi, Z. G., Reyes, V. P., Raju, B. S., Raju, A. R., Kumar, D. N., Rajagopal, P., Sathyanarayana, P. V., Rao, D. P., Srinath, K., & Peters, P. (1991). Percutaneous balloon versus surgical closed commissurotomy for mitral stenosis. A prospective, randomized trial. Circulation. https://doi.org/10.1161/01.cir.83.4.1179

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.