Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 223

The DOI matches its Crossref record.

Histopathologic validation of angioscopy and intravascular ultrasound.

Siegel, R J, Ariani, M, Fishbein, M C, Chae, J S, Park, J C, Maurer, G, Forrester, J S · 1991 · Circulation

Abstract

BACKGROUND: To establish a histopathologic basis for angioscopic and ultrasound image interpretation we studied 70 postmortem human arterial segments in vitro. METHODS AND RESULTS: We used 7- to 9-French fiber-optic angioscopes and 20- to 30-MHz intravascular ultrasound imaging catheters. Three observers assigned an angioscopic and ultrasound image classification to each vessel segment. The image and histological classification categories were then compared. The sensitivity, specificity, and accuracy of both methods separately or in combination for normal vessels were each greater than or equal to 95%. The predictive value was better for angioscopy than for ultrasound due to incorrect ultrasound interpretations of normal anatomy in the presence of thrombus. For stable atheroma the sensitivity, specificity, and accuracy of the individual methods were each greater than 90%. However, both angioscopy and ultrasound had classification errors in that disrupted atheroma was identified and classified as stable atheroma. Consequently, the predictive value was 74% for angioscopy and 78% for ultrasound. For disrupted atheroma the sensitivities for angioscopy and ultrasound were only moderate (73% and 81%, respectively), whereas the specificity, accuracy, and predictive value were each high (greater than 90%). For thrombus detection, the specificity, accuracy, and predictive value were high (greater than 93%) for each method. The sensitivity of angioscopy was 100%. However, sensitivity was lower for ultrasound (57%) due to false-negative interpretation of laminar clots in normal vessels and an inability to distinguish disrupted or stable atheroma from intraluminal thrombus. CONCLUSIONS: Contingency analyses showed that each imaging method alone or combined had significant agreement with the results obtained from histology (p less than 0.001). When assessing all cases in which angioscopy and ultrasound were concordant, there was a 92% agreement with the histological classification.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1161/01.cir.84.1.109

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 223

Metadata

Authors
Siegel, R. J., Ariani, M., Fishbein, M. C., Chae, J. S., Park, J. C., Maurer, G., & Forrester, J. S.
Venue
Circulation
Published
1991-07
Volume
84
Issue
1
Pages
109-117
ISSN
  • 0009-7322 (ISSN-L)
  • 1524-4539
OpenAlex
W1973391096
Cited by
223
References
0
FWCI
17.92
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Histopathologic validation of angioscopy and intravascular ultrasound. https://app.cochat.ai/papers/10.1161/01.cir.84.1.109
The paper
Siegel, R. J., Ariani, M., Fishbein, M. C., Chae, J. S., Park, J. C., Maurer, G., & Forrester, J. S. (1991). Histopathologic validation of angioscopy and intravascular ultrasound. Circulation. https://doi.org/10.1161/01.cir.84.1.109

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.