The DOI matches its Crossref record; 8 of the 8 references it cites were found in a registry or an index.
Exercise echocardiography versus 201Tl single-photon emission computed tomography in evaluation of coronary artery disease. Analysis of 292 patients.
Abstract
BACKGROUND: Exercise echocardiography (digital cine-loop technique) and 201Tl single-photon emission computed tomography (SPECT) were performed simultaneously in 292 patients being evaluated for coronary artery disease. METHODS AND RESULTS: Pretreadmill and posttreadmill echocardiographic images of diagnostic quality were obtained in 289 patients, and the left ventricle was divided into anterior, inferior, and lateral regions. Any wall motion or perfusion abnormality observed within each region was classified as totally reversible, fixed, or partially reversible. Exercise echocardiography and SPECT were normal in 137 patients and abnormal in 118 (88% agreement). Equal numbers of regional abnormalities were detected by one test when missed by the other. The two tests had an 82% agreement in detecting the same type of finding within the regions analyzed. SPECT detected more reversible abnormalities than echocardiography, whereas echocardiography detected more fixed abnormalities than SPECT: Regions with a fixed abnormality by echocardiography frequently showed partial reversibility of a perfusion defect by SPECT: Nearly one third of regions with fixed perfusion defects by SPECT demonstrated normal resting function or reversible abnormalities by echocardiography. Sensitivity for coronary artery disease by angiography (greater than or equal to 50% diameter stenosis) in 112 patients was similar for the two tests, ranging from 58% and 61% (echocardiography and SPECT, respectively) for one-vessel disease to 94% for three-vessel disease. The specificities for echocardiography and SPECT were 88% and 81%, respectively. CONCLUSIONS: Exercise echocardiography had a diagnostic accuracy comparable to that of SPECT for the detection of regional abnormalities produced by significant coronary artery disease. A greater number of abnormal regions were detected with the combined use of both tests.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Reversibility of Cardiac Wall-Motion Abnormalities Predicted by Positron Tomography
Tillisch, J., Brunken, R., Marshall, R., Schwaiger, M., Mandelkern, M., Phelps, M., & Schelbert, H. (1986) · New England Journal of Medicine · doi:10.1056/nejm198604033141405 · Cited by 1,285
Lieberman, A. N., Weiss, J. L., Jugdutt, B. I., Becker, L. C., Bulkley, B. H., Garrison, J. G., Hutchins, G. M., Kallman, C. A., & Weisfeldt, M. L. (1981) · Circulation · doi:10.1161/01.cir.63.4.739 · Cited by 535
Iskandrian, A. S., Heo, J., Kong, B., & Lyons, E. (1989) · Journal of the American College of Cardiology · doi:10.1016/0735-1097(89)90385-9 · Cited by 324
Armstrong, W. F., O’Donnell, J. A., Ryan, T. A., & FEIGENBAUM, H. B. (1987) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(87)80195-x · Cited by 224
Ryan, T. A., Vasey, C. G., Presti, C. F., O’Donnell, J. A., FEIGENBAUM, H. B., & Armstrong, W. F. (1988) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(98)90056-0 · Cited by 221
Maddahi, J., van Train, K., Prigent, F., Garcia, E. V., Friedman, J., Ostrzega, E., & Berman, D. (1989) · Journal of the American College of Cardiology · doi:10.1016/0735-1097(89)90017-x · Cited by 195
Prognostic value of a normal exercise echocardiogram
Sawada, S. G., Ryan, T., Conley, M. J., Corya, B. C., Feigenbaum, H., & Armstrong, W. F. (1990) · American Heart Journal · doi:10.1016/0002-8703(90)90159-u · Cited by 188
Exercise echocardiographic detection of coronary artery disease in women
Sawada, S. G., Ryan, T. A., Fineberg, N. S., Armstrong, W. F., Judson, W. E., McHenry, P. L., & FEIGENBAUM, H. B. (1989) · Journal of the American College of Cardiology · doi:10.1016/0735-1097(89)90378-1 · Cited by 162
Cited by
ACC/AHA guidelines for the management of patients with acute myocardial infarction
Committee Members, Ryan, T. J., Anderson, J. L., Antman, E. M., Braniff, B. A., Brooks, N. H., Califf, R. M., Hillis, L. D., Hiratzka, L. F., Rapaport, E., et al. (1996) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(96)00392-0 · Cited by 1,850
ACC/AHA/ASE 2003 guideline update for the clinical application of echocardiography: summary article
Cheitlin, M. D., Armstrong, W. F., Aurigemma, G. P., Beller, G. A., Bierman, F. Z., Davis, J. L., Douglas, P. S., Faxon, D. P., Gillam, L. D., Kimball, T. R., et al. (2003) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(03)01065-9 · Cited by 1,402
Pellikka, P. A., Nagueh, S. F., Elhendy, A. A., Kuehl, C. A., & Sawada, S. G. (2007) · Journal of the American Society of Echocardiography · doi:10.1016/j.echo.2007.07.003 · Cited by 793
Committee Members, Cheitlin, M. D., Armstrong, W. F., Aurigemma, G. P., Beller, G. A., Bierman, F. Z., Davis, J. L., Douglas, P. S., Faxon, D. P., Gillam, L. D., et al. (2003) · Circulation · doi:10.1161/01.cir.0000073597.57414.a9 · Cited by 745
Sicari, R., Nihoyannopoulos, P., Evangelista, A., Kasprzak, J., Lancellotti, P., Poldermans, D., Voigt, J.-U., Zamorano, J. L., & on behalf of the European Association of Echocardiography (2008) · European Journal of Echocardiography · doi:10.1093/ejechocard/jen175 · Cited by 717
Gibbons, R. J., Chatterjee, K., Daley, J., Douglas, J. S., Fihn, S. D., Gardin, J. M., Grunwald, M. A., Levy, D., Lytle, B. W., O’Rourke, R. A., et al. (1999) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(99)00150-3 · Cited by 633
Pellikka, P. A., Arruda-Olson, A., Chaudhry, F. A., Chen, M. H., Marshall, J. E., Porter, T. R., & Sawada, S. G. (2020) · Journal of the American Society of Echocardiography · doi:10.1016/j.echo.2019.07.001 · Cited by 583
Exercise Echocardiography or Exercise SPECT Imaging?: A Meta-analysis of Diagnostic Test Performance
Fleischmann, K. E., Hunink, M. G. M., Kuntz, K. M., & Douglas, P. S. (1998) · JAMA · doi:10.1001/jama.280.10.913 · Cited by 490
Underwood, S. R., Anagnostopoulos, C., Cerqueira, M., Ell, P. J., Flint, E. J., Harbinson, M., Kelion, A. D., Al-Mohammad, A., Prvulovich, E. M., Shaw, L. J., et al. (2004) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-003-1344-5 · Cited by 481
Marwick, T., D'hondt, A.-M., Baudhuin, T., Willemart, B., Wijns, W., Detry, J.-M., & Melin, J. (1993) · Journal of the American College of Cardiology · doi:10.1016/0735-1097(93)90830-t · Cited by 359
Sicari, R., Nihoyannopoulos, P., Evangelista, A., Kasprzak, J., Lancellotti, P., Poldermans, D., Voigt, J.-U., Zamorano, J. L., & on behalf of the European Association of Echocardiography (2008) · European Heart Journal · doi:10.1093/eurheartj/ehn492 · Cited by 357
Armstrong, W. F., Pellikka, P. A., Ryan, T., Crouse, L., & Zoghbi, W. A. (1998) · Journal of the American Society of Echocardiography · doi:10.1016/s0894-7317(98)70132-4 · Cited by 357
Self-citationBeleslin, B. D., Ostojic, M., Stepanovic, J., Djordjevic-Dikic, A., Stojkovic, S., Nedeljkovic, M., Stankovic, G., Petrasinovic, Z., Gojkovic, L., & Vasiljevic-Pokrajcic, Z. (1994) · Circulation · doi:10.1161/01.cir.90.3.1168 · Cited by 289
van Melle, J. P., Bot, M., de Jonge, P., de Boer, R. A., van Veldhuisen, D. J., & Whooley, M. A. (2010) · Diabetes Care · doi:10.2337/dc10-0286 · Cited by 159
CHEITLIN, M., ARMSTRONG, W., AURIGEMMA, G., BELLER, G., BIERMAN, F., DAVIS, J., DOUGLAS, P., FAXON, D., GILLAM, L., & KIMBALL, T. (2003) · Journal of the American Society of Echocardiography · doi:10.1016/s0894-7317(03)00685-0 · Cited by 107
Metadata
- Authors
- Quiñones, M. A., Verani, M. S., Haichin, R. M., Mahmarian, J. J., Suarez, J., & Zoghbi, W. A.
- Venue
- Circulation
- Published
- 1992-03
- Volume
- 85
- Issue
- 3
- Pages
- 1026-1031
- ISSN
- 0009-7322 (ISSN-L)
- 1524-4539
- OpenAlex
- W2049373023
- Cited by
- 316
- References
- 8
- FWCI
- 26.19
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.