The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.
Selective transcatheter ablation of the fast and slow pathways using radiofrequency energy in patients with atrioventricular nodal reentrant tachycardia.
Open accessAbstract
BACKGROUND: The safety and efficacy of selective fast versus slow pathway ablation using radiofrequency energy and a transcatheter technique in patients with atrioventricular nodal reentrant tachycardia (AVNRT) were evaluated. METHODS AND RESULTS: Forty-nine consecutive patients with symptomatic AVNRT were included. There were 37 women and 12 men (mean age, 43 +/- 20 years). The first 16 patients underwent a fast pathway ablation with radiofrequency current applied in the anterior/superior aspect of the tricuspid annulus. The remaining 33 patients initially had their slow pathway targeted at the posterior/inferior aspect of the right interatrial septum. The fast pathway was successfully ablated in the initial 16 patients and in three additional patients after an unsuccessful slow pathway ablation. A mean of 10 +/- 8 radiofrequency pulses were delivered; the last (successful) pulse was at a power of 24 +/- 7 W for a duration of 22 +/- 15 seconds. Four of these 19 patients developed complete atrioventricular (AV) block. In the remaining 15 patients, the post-ablation atrio-His intervals prolonged from 89 +/- 30 to 138 +/- 43 msec (p less than 0.001), whereas the shortest 1:1 AV conduction and effective refractory period of the AV node remained unchanged. Ten patients lost their ventriculoatrial (VA) conduction, and the other five had a significant prolongation of the shortest cycle length of 1:1 VA conduction (280 +/- 35 versus 468 +/- 30 msec, p less than 0.0001). Slow pathway ablation was attempted initially in 33 patients and in another two who developed uncommon AVNRT after successful fast pathway ablation. Of these 35 patients, 32 had no AVNRT inducible after 6 +/- 4 radiofrequency pulses with the last (successful) pulse given at a power of 36 +/- 12 W for a duration of 35 +/- 15 seconds. After successful slow pathway ablation, the shortest cycle length of 1:1 AV conduction prolonged from 295 +/- 44 to 332 +/- 66 msec (p less than 0.0005), the AV nodal effective refractory period increased from 232 +/- 36 to 281 +/- 61 msec (p less than 0.0001), and the atrio-His interval as well as the shortest cycle length of 1:1 VA conduction remained unchanged. No patients developed AV block. Among the last 33 patients who underwent a slow pathway ablation as the initial attempt and a fast pathway ablation only when the former failed, 32 (97%) had successful AVNRT abolition with intact AV conduction. During a mean follow-up of 6.5 +/- 3.0 months, none of the 49 patients had recurrent tachycardia. Forty patients had repeat electrophysiological studies 4-8 weeks after their successful ablation, and AVNRT could not be induced in 39 patients. CONCLUSIONS: These data suggest that both fast and slow pathways can be selectively ablated for control of AVNRT: Slow pathway ablation, however, by obviating the risk of AV block, appears to be safer and should be considered as the first approach.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Scheinman, M. M. (1982) · JAMA: The Journal of the American Medical Association · doi:10.1001/jama.1982.03330070039027 · Cited by 836
Gallagher, J. J., Svenson, R. H., Kasell, J. H., German, L. D., Bardy, G. H., Broughton, A., & Critelli, G. (1982) · New England Journal of Medicine · doi:10.1056/nejm198201283060402 · Cited by 771
Huang, S. K., Bharati, S., Graham, A. R., Lev, M., Marcus, F. I., & Odell, R. C. (1987) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(87)80388-1 · Cited by 374
Haissaguerre, M., Warin, J. F., Lemetayer, P., Saoudi, N., Guillem, J. P., & Blanchot, P. (1989) · New England Journal of Medicine · doi:10.1056/nejm198902163200704 · Cited by 218
Operative therapy of atrioventricular node reentry and results of an anatomically guided procedure
Fujimura, O., Guiraudon, G. M., Yee, R. K., Sharma, A. D., & Klein, G. J. (1989) · The American Journal of Cardiology · doi:10.1016/0002-9149(89)90576-6 · Cited by 52
Cited by
Calkins, H., Yong, P., Miller, J. M., Olshansky, B., Carlson, M., Saul, J. P., Huang, S. K. S., Liem, L. B., Klein, L. S., Moser, S. A., et al. (1999) · Circulation · doi:10.1161/01.cir.99.2.262 · Cited by 611
Ernst, S., Ouyang, F., Linder, C., Hertting, K., Stahl, F., Chun, J., Hachiya, H., Bänsch, D., Antz, M., & Kuck, K.-H. (2004) · Circulation · doi:10.1161/01.cir.0000125126.83579.1b · Cited by 353
Epstein, A. E., Miles, W. M., Benditt, D. G., Camm, A. J., Darling, E. J., Friedman, P. L., Garson, A., Harvey, J. C., Kidwell, G. A., Klein, G. J., et al. (1996) · Circulation · doi:10.1161/01.cir.94.5.1147 · Cited by 220
Unrecognized Paroxysmal Supraventricular Tachycardia: Potential for Misdiagnosis as Panic Disorder
Lessmeier, T. J. (1997) · Archives of Internal Medicine · doi:10.1001/archinte.1997.00440260085013 · Cited by 157
KOTTKAMP, H., HINDRICKS, G., SHENASA, H., CHEN, X., WICHTER, T., BORGGREFE, M., & BREITHARDT, G. (1996) · Journal of Cardiovascular Electrophysiology · doi:10.1111/j.1540-8167.1996.tb00466.x · Cited by 91
Metadata
- Authors
- Jazayeri, M. R., Hempe, S. L., Sra, J. S., Dhala, A. A., Blanck, Z., Deshpande, S. S., Avitall, B., Krum, D. P., Gilbert, C. J., & Akhtar, M.
- Venue
- Circulation
- Published
- 1992-04
- Volume
- 85
- Issue
- 4
- Pages
- 1318-1328
- ISSN
- 0009-7322 (ISSN-L)
- 1524-4539
- OpenAlex
- W2002942054
- Cited by
- 489
- References
- 5
- FWCI
- 46.42
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Selective transcatheter ablation of the fast and slow pathways using radiofrequency energy in patients with atrioventricular nodal reentrant tachycardia. https://app.cochat.ai/papers/10.1161/01.cir.85.4.1318
- The paper
- Jazayeri, M. R., Hempe, S. L., Sra, J. S., Dhala, A. A., Blanck, Z., Deshpande, S. S., Avitall, B., Krum, D. P., Gilbert, C. J., & Akhtar, M. (1992). Selective transcatheter ablation of the fast and slow pathways using radiofrequency energy in patients with atrioventricular nodal reentrant tachycardia. Circulation. https://doi.org/10.1161/01.cir.85.4.1318
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.