Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 829

The DOI matches its Crossref record.

Effective arterial elastance as index of arterial vascular load in humans.

Open access
Kelly, R P, Ting, C T, Yang, T M, Liu, C P, Maughan, W L, Chang, M S, Kass, D A·1992·Circulation

Abstract

BACKGROUND: This study tested whether the simple ratio of ventricular end-systolic pressure to stroke volume, known as the effective arterial elastance (Ea), provides a valid measure of arterial load in humans with normal and aged hypertensive vasculatures. METHODS AND RESULTS: Ventricular pressure-volume and invasive aortic pressure and flow were simultaneously determined in 10 subjects (four young normotensive and six older hypertensive). Measurements were obtained at rest, during mechanically reduced preload, and after pharmacological interventions. Two measures of arterial load were compared: One was derived from aortic input impedance and arterial compliance data using an algebraic expression based on a three-element Windkessel model of the arterial system [Ea(Z)], and the other was more simply measured as the ratio of ventricular end-systolic pressure to stroke volume [Ea(PV)]. Although derived from completely different data sources and despite the simplifying assumptions of Ea(PV), both Ea(Z) and Ea(PV) were virtually identical over a broad range of altered conditions: Ea(PV) = 0.97.Ea(Z) + 0.17; n = 33, r2 = 0.98, SEE = 0.09, p less than 0.0001. Whereas Ea(PV) also correlated with mean arterial resistance, it exceeded resistance by as much as 25% in older hypertensive subjects (because of reduced compliance and wave reflections), which better indexed the arterial load effects on the ventricle. Simple methods to estimate Ea (PV) from routine arterial pressures were tested and validated. CONCLUSIONS: Ea(PV) provides a convenient, useful method to assess arterial load and its impact on the human ventricle. These results highlight effects of increased pulsatile load caused by aging or hypertension on the pressure-volume loop and indicate that this load and its effects on cardiac performance are often underestimated by mean arterial resistance but are better accounted for by Ea.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1161/01.cir.86.2.513

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 829

Metadata

Authors
Kelly, R. P., Ting, C. T., Yang, T. M., Liu, C. P., Maughan, W. L., Chang, M. S., & Kass, D. A.
Venue
Circulation
Published
1992-08
Volume
86
Issue
2
Pages
513-521
ISSN
  • 0009-7322 (ISSN-L)
  • 1524-4539
OpenAlex
W2082543306
Cited by
829
References
0
FWCI
3.73
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Effective arterial elastance as index of arterial vascular load in humans. https://app.cochat.ai/papers/10.1161/01.cir.86.2.513
The paper
Kelly, R. P., Ting, C. T., Yang, T. M., Liu, C. P., Maughan, W. L., Chang, M. S., & Kass, D. A. (1992). Effective arterial elastance as index of arterial vascular load in humans. Circulation. https://doi.org/10.1161/01.cir.86.2.513

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.