The DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.
Electrophysiological effects of myocardial stretch and mechanical determinants of stretch-activated arrhythmias.
Open accessAbstract
BACKGROUND: Although the existence of myocardial mechanoelectrical feedback is well established, the mechanism of arrhythmia induction by ventricular dilatation or stretch remains insufficiently defined. In particular, controversy exists when comparing the arrhythmogenic potential of chronic versus acute myocardial stretch. Also, assessment of cellular electrophysiological effects of myocardial stretch has been incomplete. METHODS AND RESULTS: To evaluate the electrophysiological and arrhythmogenic effects of slow versus rapid ventricular wall stretch, we developed an isolated Langendorff-perfused rabbit heart model in which left ventricular (LV) volume can be changed by a computer-controlled servopump. Cellular electrophysiological effects and premature ventricular excitations (PVEs) and their origin produced by the volume increases were assessed by a multiple-site monophasic action potential (MAP) recording system and by volume-conducted ECGs obtained by immersing the entire preparation in a saline-filled tank. Volume was increased either gradually with slow volume ramps (0.1 ml/sec) or suddenly by volume pulses of varying pulse waveforms (three different amplitudes and five different rise velocities) applied randomly 250-350 times to each of eight hearts. Gradual LV volume loading caused gradual decreases in MAP resting and action potential amplitude, whereas rapid, transient volume pulses caused transient depolarizations. Despite similar membrane potential effects of stretch, gradual volume increases rarely (11%) produced PVEs, even with large volume loads, whereas rapid volume pulses of moderate amplitudes regularly triggered PVEs (45-100% of interventions). Logistic regression analysis showed that the probability of PVE occurrence increased independently with both the amplitude and the velocity of the volume increase, with the greatest sensitivity to stretch velocity exhibited at low and intermediate pulse amplitudes. Faster volume pulse rise velocities triggered PVEs at a lower instantaneous pulse amplitude than lower rise velocities, further corroborating the dependence of stretch-activated arrhythmias on the velocity of stretch. In contrast, an increase in the basic ventricular volume had no effect on the probability of PVE occurrence during the volume pulses. The MAP recordings demonstrated spatial variability in the extent of local depolarizations and site of PVE origin; transient depolarizations occurred, and PVEs originated most often in the posterolateral region of the left ventricle. CONCLUSIONS: Membrane depolarization is caused by both gradual and rapid ventricular stretch, but PVEs are more easily elicited by rapid stretch. Regions of greater myocardial compliance that experience greater relative stretch may act as "foci" for stretch-activated arrhythmias during dynamic ventricular loading. These whole-heart data corroborate the existence of stretch-activated membrane channels in ventricular myocardium and may help explain ventricular ectopy under conditions of differential ventricular loading, as in ventricular dyskinesia, or regional muscle traction, as in mitral valve prolapse syndrome.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Stretch‐activated single ion channel currents in tissue‐cultured embryonic chick skeletal muscle.
Guharay, F., & Sachs, F. (1984) · The Journal of Physiology · doi:10.1113/jphysiol.1984.sp015317 · Cited by 995
Determinants of Survival in Patients with Ventricular Tachyarrhythmias
Swerdlow, C. D., Winkle, R. A., & Mason, J. W. (1983) · New England Journal of Medicine · doi:10.1056/nejm198306163082402 · Cited by 509
Mechanically induced action potential changes and arrhythmia in isolated and in situ canine hearts
Franz, M. R., Burkhoff, D., Yue, D. T., & SAGAWA, K. (1989) · Cardiovascular Research · doi:10.1093/cvr/23.3.213 · Cited by 200
Self-citationStretch activated ion channels in ventricular myocytes
Craelius, W., Chen, V., & El-Sherif, N. (1988) · Bioscience Reports · doi:10.1007/bf01121637 · Cited by 190
In vitro validation of a new cardiac catheter technique for recording monophasic action potentials
FRANZ, M. R., BURKHOFF, D., SPURGEON, H., WEISFELDT, M. L., & LAKATTA, E. G. (1986) · European Heart Journal · doi:10.1093/oxfordjournals.eurheartj.a061954 · Cited by 176
Self-citationKAUFMANN, R. L., & Theophile, U. (1967) · Pflügers Archiv - European Journal of Physiology · doi:10.1007/bf00362710 · Cited by 132
Cited by
Somers, V. K., White, D. P., Amin, R., Abraham, W. T., Costa, F., Culebras, A., Daniels, S., Floras, J. S., Hunt, C. E., Olson, L. J., et al. (2008) · Circulation · doi:10.1161/circulationaha.107.189420 · Cited by 1,297
Ravelli, F., & Allessie, M. (1997) · Circulation · doi:10.1161/01.cir.96.5.1686 · Cited by 477
Obstructive Sleep Apnea and Heart Failure
Kasai, T., & Bradley, T. D. (2011) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2010.08.627 · Cited by 345
Ryan, C. M. (2005) · Thorax · doi:10.1136/thx.2005.040972 · Cited by 266
Three-dimensional analysis of regional cardiac function: a model of rabbit ventricular anatomy
Vetter, F. J., & McCulloch, A. D. (1998) · Progress in Biophysics and Molecular Biology · doi:10.1016/s0079-6107(98)00006-6 · Cited by 255
Metadata
- Authors
- Franz, M. R., Cima, R., Wang, D., Profitt, D., & Kurz, R.
- Venue
- Circulation
- Published
- 1992-09
- Volume
- 86
- Issue
- 3
- Pages
- 968-978
- ISSN
- 0009-7322 (ISSN-L)
- 1524-4539
- OpenAlex
- W1885774346
- Cited by
- 411
- References
- 6
- FWCI
- 5.42
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Electrophysiological effects of myocardial stretch and mechanical determinants of stretch-activated arrhythmias. https://app.cochat.ai/papers/10.1161/01.cir.86.3.968
- The paper
- Franz, M. R., Cima, R., Wang, D., Profitt, D., & Kurz, R. (1992). Electrophysiological effects of myocardial stretch and mechanical determinants of stretch-activated arrhythmias. Circulation. https://doi.org/10.1161/01.cir.86.3.968
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.