The DOI matches its Crossref record.
Radiofrequency catheter ablation of ventricular tachycardia in patients with coronary artery disease.
Abstract
BACKGROUND: Radiofrequency (RF) ablation of idiopathic ventricular tachycardia (VT) has been demonstrated to be highly efficacious, but the efficacy of RF ablation of VT in patients with coronary artery disease has been unknown. Therefore, the purpose of this study was to determine the feasibility of RF ablation of VT in patients with coronary artery disease. METHODS AND RESULTS: Fifteen consecutive patients with coronary artery disease and a history of myocardial infarction underwent an attempt at RF ablation of 16 hemodynamically stable monomorphic VTs that had been documented clinically on a 12-lead ECG and that had not been successfully managed by pharmacological or device therapy. One VT was incessant, five occurred more than 25 times, and the remainder occurred two to 20 times. An additional four VTs that had not been documented clinically also were targeted for ablation. The mean age of the patients was 68 +/- 7 years (+/- SD), and their mean left ventricular ejection fraction was 0.27 +/- 0.08. The mean cycle length of the 20 VTs targeted for ablation was 438 +/- 82 msec. Ablation sites were selected based on endocardial activation mapping, pace mapping, identification of an isolated mid-diastolic potential, or concealed entrainment. Sixteen of the 20 VTs (80%) were successfully ablated in 11 of 15 patients (73%), using a mean of 4.2 +/- 3 applications of RF energy, and no recurrences of the ablated VTs occurred during 9.1 +/- 3.3 months of follow-up. The mean duration of the ablation procedures was 128 +/- 30 minutes. No complications occurred in any of the patients. CONCLUSIONS: The results of this study demonstrate that RF ablation of hemodynamically stable VT is feasible as adjunctive therapy in selected patients with coronary artery disease.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Zipes, D. P., Camm, A. J., Borggrefe, M., Buxton, A. E., Chaitman, B., Fromer, M., Gregoratos, G., Klein, G., Moss, A. J., Myerburg, R. J., et al. (2006) · Circulation · doi:10.1161/circulationaha.106.178233 · Cited by 1,080
Committee Members, Gregoratos, G., Abrams, J., Epstein, A. E., Freedman, R. A., Hayes, D. L., Hlatky, M. A., Kerber, R. E., Naccarelli, G. V., Schoenfeld, M. H., et al. (2002) · Circulation · doi:10.1161/01.cir.0000035996.46455.09 · Cited by 910
EHRA/HRS Expert Consensus on Catheter Ablation of Ventricular Arrhythmias
Aliot, E. M., Stevenson, W. G., Almendral-Garrote, J. M., Bogun, F., Calkins, C. H., Delacretaz, E., Della Bella, P., Hindricks, G., Jaïs, P., Josephson, M. E., et al. (2009) · Heart Rhythm · doi:10.1016/j.hrthm.2009.04.030 · Cited by 770
Nakagawa, H., Beckman, K. J., McClelland, J. H., Wang, X., Arruda, M., Santoro, I., Hazlitt, H. A., Abdalla, I., Singh, A., & Gossinger, H. (1993) · Circulation · doi:10.1161/01.cir.88.6.2607 · Cited by 437
TANNER, H., HINDRICKS, G., VOLKMER, M., FURNISS, S., KÜHLKAMP, V., LACROIX, D., DE CHILLOU, C., ALMENDRAL, J., CAPONI, D., KUCK, K., et al. (2010) · Journal of Cardiovascular Electrophysiology · doi:10.1111/j.1540-8167.2009.01563.x · Cited by 265
Metadata
- Authors
- Morady, F., Harvey, M., Kalbfleisch, S. J., el-Atassi, R., Calkins, H., & Langberg, J. J.
- Venue
- Circulation
- Published
- 1993-02
- Volume
- 87
- Issue
- 2
- Pages
- 363-372
- ISSN
- 0009-7322 (ISSN-L)
- 1524-4539
- OpenAlex
- W1979822717
- Cited by
- 427
- References
- 0
- FWCI
- 26.45
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Radiofrequency catheter ablation of ventricular tachycardia in patients with coronary artery disease. https://app.cochat.ai/papers/10.1161/01.cir.87.2.363
- The paper
- Morady, F., Harvey, M., Kalbfleisch, S. J., el-Atassi, R., Calkins, H., & Langberg, J. J. (1993). Radiofrequency catheter ablation of ventricular tachycardia in patients with coronary artery disease. Circulation. https://doi.org/10.1161/01.cir.87.2.363
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.