Radiofrequency endocardial catheter ablation of accessory atrioventricular pathway atrial insertion sites.
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
BACKGROUND: High rates of success using radiofrequency ablation energy have rapidly transformed catheter ablation from an investigational procedure to the nonpharmacological therapy of choice for symptomatic Wolff-Parkinson-White syndrome. Prior studies of radiofrequency accessory pathway ablation were based on a ventricular approach. Risks associated with prolonged arterial catheter manipulation, retrograde left ventricular catheterization, and production of ventricular lesions required for successful ventricular insertion ablation can be avoided using atrial insertion ablation procedures. The purpose of the present study was to define the safety and efficacy of accessory pathway ablation using radiofrequency energy delivered solely to accessory atrioventricular pathway atrial insertion sites. METHODS AND RESULTS: One hundred fourteen patients with accessory pathway-mediated tachycardia underwent attempted radiofrequency current ablation at the accessory pathway atrial insertion site. All catheters were introduced transvenously. Left-sided accessory pathways were approached using transseptal left atrial catheterization techniques. Retrograde localization of the atrial insertion site during reentrant tachycardia was characterized by 40 +/- 15-msec local ventriculoatrial and 79 +/- 17-msec surface QRS to local atrial electrogram intervals. Presumed accessory pathway potentials were present in only 30% of ablation site electrograms. Successful ablation required 6.2 +/- 5.3 radiofrequency energy applications. Cumulative energy dose required for success was 2,341 +/- 2,233 J. There were no complications associated with transseptal catheterization. Energy delivery to accessory pathway atrial insertion sites was associated with non-life-threatening complications in two patients. Recurrent conduction requiring repeat ablation occurred in 10 of 115 (9%) successfully ablated accessory pathways, all within 1 month of the ablation procedure. After 21.2 +/- 4.6 months of follow-up, 108 of 114 (95%) patients are asymptomatic and without evidence of accessory pathway conduction. CONCLUSIONS: The atrial insertion approach to accessory pathway ablation is safe and highly effective. This approach compares favorably with the retrograde ventricular insertion ablation technique. Atrial insertion ablation eliminates the need to produce ventricular lesions and avoids the risks of prolonged arterial catheter manipulation and retrograde left ventricular catheterization.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Jackman, W. M., Wang, X., Friday, K. J., Roman, C. A., Moulton, K. P., Beckman, K. J., McClelland, J. H., Twidale, N., Hazlitt, H. A., Prior, M. I., et al. (1991) · New England Journal of Medicine · doi:10.1056/nejm199106063242301 · Cited by 1,422
Cited by
Zipes, D. P., Camm, A. J., Borggrefe, M., Buxton, A. E., Chaitman, B., Fromer, M., Gregoratos, G., Klein, G., Myerburg, R. J., Quinones, M. A., et al. (2006) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2006.07.010 · Cited by 1,973
Self-citationZipes, D. P., Camm, A. J., Borggrefe, M., Buxton, A. E., Chaitman, B., Fromer, M., Gregoratos, G., Klein, G., Moss, A. J., Myerburg, R. J., et al. (2006) · Circulation · doi:10.1161/circulationaha.106.178233 · Cited by 1,080
Self-citationWriting Committee Members, Zipes, D. P., Camm, A. J., Borggrefe, M., Buxton, A. E., Chaitman, B., Fromer, M., Gregoratos, G., Klein, G., Moss, A. J., et al. (2006) · Europace · doi:10.1093/europace/eul108 · Cited by 738
Self-citationCalkins, H., Yong, P., Miller, J. M., Olshansky, B., Carlson, M., Saul, J. P., Huang, S. K. S., Liem, L. B., Klein, L. S., Moser, S. A., et al. (1999) · Circulation · doi:10.1161/01.cir.99.2.262 · Cited by 611
“90 AVNRT (15), AVJ (10), SAP (10), LFW AP (13§), FRW AP (5), PS AP (7)”
Radio-Frequency Ablation as Treatment for Cardiac Arrhythmias
Morady, F. (1999) · New England Journal of Medicine · doi:10.1056/nejm199902183400707 · Cited by 281
Metadata
- Authors
- Swartz, J. F., Tracy, C. M., & Fletcher, R. D.
- Venue
- Circulation
- Published
- 1993-02
- Volume
- 87
- Issue
- 2
- Pages
- 487-499
- ISSN
- 0009-7322 (ISSN-L)
- 1524-4539
- OpenAlex
- W1995964346
- Cited by
- 140
- References
- 1
- FWCI
- 10.27
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.