Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 325

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Quantitative Doppler assessment of valvular regurgitation.

Open access
Enriquez-Sarano, M, Bailey, K R, Seward, J B, Tajik, A J, Krohn, M J, Mays, J M·1993·Circulation

Abstract

BACKGROUND: Quantitation of valvular regurgitation remains a challenge. The accuracy of quantitative Doppler is controversial, and its ability to measure regurgitant volume is unknown; therefore, it is not widely used. METHODS AND RESULTS: In 120 patients (20 without regurgitation, 19 with aortic regurgitation, and 81 with mitral regurgitation), the stroke volume through the mitral annulus and left ventricular outflow tract were measured using pulsed-wave Doppler concurrently with left ventricular stroke volume calculated using left ventricular volumes measured by two-dimensional echocardiography Simpson's biapical method. Regurgitant volume and fraction were thus computed using Doppler or ventricular methods. In normal patients there were good correlations between Doppler and left ventricular measurements of stroke volume. Doppler regurgitant volume and fraction were 4.4 +/- 4.4 mL and 5.3 +/- 4.5%, respectively. In patients with aortic regurgitation, there were good correlations between Doppler and left ventricular measurements of stroke volume, regurgitant volume, and regurgitant fraction (r = 0.97, r = 0.95, and r = 0.93, respectively; p < 0.0001). In patients with mitral regurgitation, despite good correlations between Doppler and ventricular methods for stroke volume, regurgitant volume, and regurgitant fraction (r = 0.94, r = 0.93, and r = 0.94, respectively; p < 0.001), these variables were overestimated by Doppler. However, in the last 54 patients compared with the first 27, overestimation decreased significantly for regurgitant volume (5 +/- 10 mL versus 18 +/- 27 mL, p < 0.05) and regurgitant fraction (3.3 +/- 6.7% versus 6.2 +/- 6.8%, p = 0.05). CONCLUSIONS: Quantitative Doppler can be performed in large numbers of patients in a clinical laboratory. Its potential limitation was identified as overestimation of mitral regurgitation, which is overcome with increased experience. Its achieved accuracy in mitral and aortic regurgitation allows measurement not only of regurgitant fraction but most importantly of regurgitant volume.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1161/01.cir.87.3.841

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 2 references

Cited by

See all 325

Metadata

Authors
Enriquez-Sarano, M., Bailey, K. R., Seward, J. B., Tajik, A. J., Krohn, M. J., & Mays, J. M.
Venue
Circulation
Published
1993-03
Volume
87
Issue
3
Pages
841-848
ISSN
  • 0009-7322 (ISSN-L)
  • 1524-4539
OpenAlex
W2047529056
Cited by
325
References
2
FWCI
6.85
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Quantitative Doppler assessment of valvular regurgitation. https://app.cochat.ai/papers/10.1161/01.cir.87.3.841
The paper
Enriquez-Sarano, M., Bailey, K. R., Seward, J. B., Tajik, A. J., Krohn, M. J., & Mays, J. M. (1993). Quantitative Doppler assessment of valvular regurgitation. Circulation. https://doi.org/10.1161/01.cir.87.3.841

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.