CoChat

Assessment of the human splanchnic venous volume-pressure relation using radionuclide plethysmography. Effect of nitroglycerin.

Open access
Manyari, D E, Wang, Z, Cohen, J, Tyberg, J V · 1993 · Circulation
Cited by 35

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Abstract

BACKGROUND: No method exists to assess human splanchnic venous function, the most important region in terms of vascular capacity. METHODS AND RESULTS: We studied 25 stable patients without heart failure or hypertension to develop a method to assess the splanchnic venous volume-pressure (V-P) relation and to determine the effect of nitroglycerin (GTN). We used blood pool scintigraphy to assess changes in regional splanchnic vascular volume (SVV) and low levels of continuous positive airway pressure (CPAP) to passively alter venous pressure and thus, SVV. We postulated that the relation between SVV and the CPAP used would reflect the capacitance of the splanchnic venous bed and that changes in the position of this relation would provide a relative measurement of any change in capacitance. In 12 patients (group 1), the splanchnic vascular V-P curves were recorded before and 2, 9, and 20 minutes after 0.6 mg sublingual GTN; in eight patients (group 2), recordings were made at similar times before and after sublingual administration of placebo; in five patients (group 3), the hemodynamic effects of CPAP were assessed by means of right and left cardiac catheterization. Right atrial and femoral venous pressures increased (p < 0.001) and cardiac output fell (p < 0.05) during CPAP. There was an apparently linear relation between CPAP and SVV (r = 0.74-0.98); SVV increased an average of 7.4 +/- 2.2% (p < 0.001) by 12 cm H2O CPAP: The splanchnic vascular V-P curves were reproducible with minimal variability in SVV (+/- 2%, p > 0.2) in group 2. After administration of GTN, the splanchnic vascular V-P curve shifted away from the pressure axis in a parallel fashion by an average of 9.4 +/- 5.4% (p < 0.001). CONCLUSIONS: We have developed a reproducible noninvasive technique that may be used to assess human splanchnic venous V-P relations. We have demonstrated for the first time in humans that GTN exerts its dilatory effect by increasing the unstressed splanchnic venous volume.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1161/01.cir.87.4.1142

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 35

Metadata

Authors
Manyari, D. E., Wang, Z., Cohen, J., & Tyberg, J. V.
Venue
Circulation
Published
1993-04
Volume
87
Issue
4
Pages
1142-1151
ISSN
  • 0009-7322 (ISSN-L)
  • 1524-4539
OpenAlex
W2061949683
Cited by
35
References
2
FWCI
1.87
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.