The DOI matches its Crossref record; 15 of the 15 references it cites were found in a registry or an index.
Experimental basis of determining maximum coronary, myocardial, and collateral blood flow by pressure measurements for assessing functional stenosis severity before and after percutaneous transluminal coronary angioplasty.
Abstract
BACKGROUND: Severity of coronary artery stenosis has been defined in terms of geometric dimensions, pressure gradient-flow relations, resistance to flow and coronary flow reserve, or maximum flow capacity after maximum arteriolar vasodilation. A direct relation between coronary pressure and flow, however, may only be presumed if the resistances in the coronary circulation are constant (and minimal) as theoretically is the case during maximum arteriolar vasodilation. In that case, pressure measurements theoretically can be used to predict maximum flow and assess functional stenosis severity. METHODS AND RESULTS: A theoretical model was developed for the different components of the coronary circulation, and a set of equations was derived by which the relative maximum flow or fractional flow reserve in both the stenotic epicardial artery and the myocardial vascular bed and the proportional contribution of coronary arterial and collateral flow to myocardial blood flow are calculated from measurements of arterial, distal coronary, and central venous pressures during maximum arteriolar vasodilation. To test this model, five dogs were acutely instrumented with an epicardial, coronary Doppler flow velocity transducer. Distal coronary pressures were measured by an ultrathin pressure-monitoring guide wire (0.015 in.) with minimal influence on transstenotic pressure gradient. Fractional flow reserve was calculated from the pressure measurements and compared with relative maximum coronary artery flow measured directly by the Doppler flowmeter at three different levels of arterial pressure for each of 12 different severities of stenosis at each pressure level. Relative maximum blood flow through the stenotic artery (Qs) measured directly by the Doppler flowmeter showed an excellent correlation with the pressure-derived values of Qs (r = 0.98 +/- 0.01, intercept = 0.02 +/- 0.03, slope = 0.98 +/- 0.04), of the relative maximum myocardial flow (r = 0.98 +/- 0.02, intercept = 0.26 +/- 0.07, slope = 0.73 +/- 0.08), and of the collateral blood flow (r = 0.96 +/- 0.04, intercept = 0.24 +/- 0.07, slope = -0.24 +/- 0.06). Moreover, the theoretically predicted constant relation between mean arterial pressure and coronary wedge pressure, both corrected for venous pressure, was confirmed experimentally (r = 0.97 +/- 0.03, intercept = 9.5 +/- 13.3, slope = 4.4 +/- 1.2). CONCLUSIONS: These results provide the experimental basis for determining relative maximum flow or fractional flow reserve of both the epicardial coronary artery and the myocardium, including collateral flow, from pressure measurements during maximum arteriolar vasodilation. With a suitable guide wire for reliably measuring distal coronary pressure clinically, this method may have potential applications during percutaneous transluminal coronary angioplasty for assessing changes in the functional severity of coronary artery stenoses and for estimating collateral flow achievable during occlusion of the coronary artery.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Effects of adenosine on human coronary arterial circulation.
Wilson, R. F., Wyche, K., Christensen, B. V., Zimmer, S., & Laxson, D. D. (1990) · Circulation · doi:10.1161/01.cir.82.5.1595 · Cited by 906
Maximal coronary flow and the concept of coronary vascular reserve.
Hoffman, J. I. (1984) · Circulation · doi:10.1161/01.cir.70.2.153 · Cited by 592
The collateral circulation of the heart
Schaper, W., Görge, G., Winkler, B., & Schaper, J. (1988) · Progress in Cardiovascular Diseases · doi:10.1016/0033-0620(88)90011-4 · Cited by 589
Coronary flow reserve as a physiologic measure of stenosis severity
Gould, K. L., Kirkeeide, R. L., & Buchi, M. (1990) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(10)80078-6 · Cited by 548
Self-citationWilson, R. F., Laughlin, D. E., Ackell, P. H., Chilian, W. M., Holida, M. D., Hartley, C. J., Armstrong, M. L., Marcus, M. L., & White, C. W. (1985) · Circulation · doi:10.1161/01.cir.72.1.82 · Cited by 509
Wilson, R. F., & White, C. W. (1986) · Circulation · doi:10.1161/01.cir.73.3.444 · Cited by 385
Spaan, J. A., Breuls, N. P., & Laird, J. D. (1981) · Circulation Research · doi:10.1161/01.res.49.3.584 · Cited by 322
Myocardial Ischemia Caused by Distal Coronary-Artery Constriction in Stable Angina Pectoris
Pupita, G., Maseri, A., Kaski, J. C., Galassi, A. R., Gavrielides, S., Davies, G., & Crea, F. (1990) · New England Journal of Medicine · doi:10.1056/nejm199008233230804 · Cited by 148
Coronary pressure-flow relationships. Controversial issues and probable implications.
Klocke, F. J., Mates, R. E., Canty, J. M., & Ellis, A. K. (1985) · Circulation Research · doi:10.1161/01.res.56.3.310 · Cited by 145
Ellis, A. K., & Klocke, F. J. (1980) · Circulation Research · doi:10.1161/01.res.46.1.68 · Cited by 133
Gould, K. L. (1988) · Circulation · doi:10.1161/01.cir.78.2.237 · Cited by 122
Self-citation(1991) · Annals of Internal Medicine · doi:10.7326/0003-4819-115-4-335_3 · Cited by 96
Yamamoto, H., Tomoike, H., Shimokawa, H., et al. (1984) · Circulation Research · doi:10.1161/01.res.55.5.623 · Cited by 63
Percutaneous transluminal coronary angioplasty: Ten year's experience
Chokshi, S. K., Meyers, S. N., & Abi‐Mansour, P. (1987) · Progress in Cardiovascular Diseases · doi:10.1016/0033-0620(87)90012-0 · Cited by 43
Schaper, W. K. A. (1982) · Circulation · doi:10.1161/01.cir.65.5.905 · Cited by 42
Cited by
Fractional Flow Reserve versus Angiography for Guiding Percutaneous Coronary Intervention
Tonino, P. A. L., De Bruyne, B., Pijls, N. H. J., Siebert, U., Ikeno, F., van `t Veer, M., Klauss, V., Manoharan, G., Engstrøm, T., Oldroyd, K. G., et al. (2009) · New England Journal of Medicine · doi:10.1056/nejmoa0807611 · Cited by 4,260
Self-citationFractional Flow Reserve–Guided PCI versus Medical Therapy in Stable Coronary Disease
De Bruyne, B., Pijls, N. H. J., Kalesan, B., Barbato, E., Tonino, P. A. L., Piroth, Z., Jagic, N., Möbius-Winkler, S., Rioufol, G., Witt, N., et al. (2012) · New England Journal of Medicine · doi:10.1056/nejmoa1205361 · Cited by 2,772
Self-citationMeasurement of Fractional Flow Reserve to Assess the Functional Severity of Coronary-Artery Stenoses
Pijls, N. H. J., de Bruyne, B., Peels, K., van der Voort, P. H., Bonnier, H. J. R. M., Bartunek, J., & Koolen, J. J. (1996) · New England Journal of Medicine · doi:10.1056/nejm199606273342604 · Cited by 2,321
Self-citationWRITING COMMITTEE MEMBERS, Smith, S. C., Feldman, T. E., Hirshfeld, J. W., Jacobs, A. K., Kern, M. J., King, S. B., Morrison, D. A., O’Neill, W. W., Schaff, H. V., et al. (2006) · Circulation · doi:10.1161/circulationaha.105.170815 · Cited by 2,218
Koo, B.-K., Erglis, A., Doh, J.-H., Daniels, D. V., Jegere, S., Kim, H.-S., Dunning, A., DeFrance, T., Lansky, A., Leipsic, J., et al. (2011) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2011.06.066 · Cited by 1,282
Metadata
- Authors
- Pijls, N. H., van Son, J. A., Kirkeeide, R. L., De Bruyne, B., & Gould, K. L.
- Venue
- Circulation
- Published
- 1993-04
- Volume
- 87
- Issue
- 4
- Pages
- 1354-1367
- ISSN
- 0009-7322 (ISSN-L)
- 1524-4539
- OpenAlex
- W2001110351
- Cited by
- 1,183
- References
- 15
- FWCI
- 12.43
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.