Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 167

The DOI matches its Crossref record.

Continuous 12-lead ST-segment recovery analysis in the TAMI 7 study. Performance of a noninvasive method for real-time detection of failed myocardial reperfusion.

Open access
Krucoff, M W, Croll, M A, Pope, J E, Granger, C B, O'Connor, C M, Sigmon, K N, Wagner, B L, Ryan, J A, Lee, K L, Kereiakes, D J · 1993 · Circulation

Abstract

BACKGROUND: If a practical, reliable, noninvasive marker of failed reperfusion was available in real time, the benefits of further therapy in this patient subgroup could be tested. We developed a method of 12-lead ST-segment recovery analysis using continuously updated reference points to provide such a marker. METHODS AND RESULTS: In this study, our method was prospectively tested in 144 patients given thrombolytic therapy early in myocardial infarction. All patients had 12-lead continuous ST-segment monitoring and acute angiography, each analyzed in an independent, blinded core laboratory. ST-segment recovery and re-elevation were analyzed up to the moment of angiography, at which time patency was predicted. Predictions were correlated to angiographic infarct artery flow, with TIMI flow 0 to 1 as occluded and TIMI flow 2 to 3 as patent. Infarct artery occlusion was seen on first injection in 27% of patients. The positive predictive value of incomplete ST recovery or ST re-elevation by our method was 71%, negative predictive value 87%, with 90% specificity and 64% sensitivity for coronary occlusion. ST recovery analysis predicted patency in 94% of patients with TIMI 3 flow versus 81% of patients with TIMI 2 flow and predicted occlusion in 57% of patients with collateralized occlusion versus 72% of patients with non-collateralized occlusion. In a regression model including other noninvasive clinical descriptors, ST recovery alone contained the vast majority of predictive information about patency. CONCLUSIONS: In a blinded, prospective, angiographically correlated study design, 12-lead continuous ST-segment recovery analysis shows promise as a practical noninvasive marker of failed reperfusion that may contribute substantially to currently available bedside assessment. Our data also suggest that patients with TIMI 2 flow or with collateralized occlusions may represent a physiological spectrum definable with ST-segment recovery analysis.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1161/01.cir.88.2.437

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 167

Metadata

Authors
Krucoff, M. W., Croll, M. A., Pope, J. E., Granger, C. B., O'Connor, C. M., Sigmon, K. N., Wagner, B. L., Ryan, J. A., Lee, K. L., & Kereiakes, D. J.
Venue
Circulation
Published
1993-08
Volume
88
Issue
2
Pages
437-446
ISSN
  • 0009-7322 (ISSN-L)
  • 1524-4539
OpenAlex
W2028790997
Cited by
167
References
0
FWCI
11.51
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Continuous 12-lead ST-segment recovery analysis in the TAMI 7 study. Performance of a noninvasive method for real-time detection of failed myocardial reperfusion. https://app.cochat.ai/papers/10.1161/01.cir.88.2.437
The paper
Krucoff, M. W., Croll, M. A., Pope, J. E., Granger, C. B., O'Connor, C. M., Sigmon, K. N., Wagner, B. L., Ryan, J. A., Lee, K. L., & Kereiakes, D. J. (1993). Continuous 12-lead ST-segment recovery analysis in the TAMI 7 study. Performance of a noninvasive method for real-time detection of failed myocardial reperfusion. Circulation. https://doi.org/10.1161/01.cir.88.2.437

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.