Comparative effects of ischemia and hypoxemia on left ventricular systolic and diastolic function in humans.
Open accessThe DOI matches its Crossref record.
Abstract
BACKGROUND: During the initial phase of an ischemic insult, left ventricular (LV) performance depends on the complex interaction between oxygen deprivation, vascular turgor, and accumulation of metabolites. In experimental preparations, low-flow ischemia decreases systolic shortening and increases diastolic LV distensibility, whereas pacing-induced ischemia or hypoxic perfusion produces smaller decreases in systolic shortening but decreases LV diastolic distensibility. The purpose of this study was to investigate the different effects of low-flow ischemia, pacing-induced ischemia, and hypoxemic perfusion on LV performance in humans. METHODS AND RESULTS: In 20 patients with a significant stenosis in the left anterior descending coronary artery, micromanometer-tip LV pressure recordings (n = 20), LV angiography (n = 18), and coronary sinus blood sampling (n = 11) were obtained at rest and during the following conditions: pacing-induced ischemia (PI) (n = 11), low-flow ischemia of balloon coronary occlusion (CO) (n = 20), and hypoxemia induced by balloon coronary occlusion with hypoxemic perfusion distal to the occlusion (CO+P) (n = 11). LV stroke work index fell from 75 +/- 17 g.m at rest to 43 +/- 14 g.m at the end of CO (n = 18; P < .001). In addition, LV stroke work index was lower at the end of CO than during PI (50 +/- 11 vs 77 +/- 15 g.m; n = 11; P < .002) and was lower at the end of CO than at the end of CO+P (35 +/- 7 vs 46 +/- 9 g.m; n = 9; P < .02). LV end-diastolic pressure rose from 16 +/- 5 mm Hg at rest to 23 +/- 6 mm Hg at the end of CO (n = 20; P < .001). However, LV end-diastolic pressure was lower at the end of CO than during PI (20 +/- 5 vs 30 +/- 5 mm Hg; n = 11; P < .002) and was lower at the end of CO than at the end of CO+P (26 +/- 5 vs 34 +/- 7 mm Hg; n = 11; P < .01). LV end-diastolic volume index increased from 75 +/- 14 mL/m2 at rest to 79 +/- 15 mL/m2 at the end of CO (n = 18; P < .05). Left ventricular end-diastolic volume index increased to values similar to those for CO during PI (79 +/- 13 mL/m2; n = 11; P = NS) and at the end of CO+P (78 +/- 14 mL/m2; n = 9; P = NS). Higher values of LV end-diastolic pressure and unchanged values of LV end-diastolic volume index for PI and CO+P, compared with CO, suggested a lower end-diastolic LV distensibility during PI and during hypoxemia, as compared with low-flow ischemia. Upward shifts of individual diastolic LV pressure-volume curves during PI (9 of 11 patients) and at the end of CO+P (7 of 9 patients), compared with CO, were also consistent with lower LV diastolic distensibility during pacing-induced ischemia and during hypoxemia, compared with low-flow ischemia. Coronary sinus lactate, H+, and K+ levels increased after balloon deflation (CO and CO+P) and during pacing (PI). CONCLUSIONS: Thus, during low-flow ischemia, LV systolic performance was lower and LV diastolic distensibility larger than during pacing-induced ischemia or hypoxemia. The variable response of the human myocardium to different types of ischemia was probably related to the degree of vascular turgor and accumulation of tissue metabolites.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
What Mechanisms Underlie Diastolic Dysfunction in Heart Failure?
Kass, D. A., Bronzwaer, J. G. F., & Paulus, W. J. (2004) · Circulation Research · doi:10.1161/01.res.0000129254.25507.d6 · Cited by 480
Self-citationSaoudi, N., Cosío, F., Waldo, A., Chen, S. A., Iesaka, Y., Lesh, M., Saksena, S., Salerno, J., & Schoels, W. (2001) · European Heart Journal · doi:10.1053/euhj.2001.2658 · Cited by 464
Paracrine Coronary Endothelial Control of Left Ventricular Function in Humans
Paulus, W. J., Vantrimpont, P. J., & Shah, A. M. (1995) · Circulation · doi:10.1161/01.cir.92.8.2119 · Cited by 173
Self-citationAtrial Flutter Mapping and Ablation I: Studying Atrial Flutter Mechanisms by Mapping and Entrainment
COSIO, F. G., ARRIBAS, F., LÓPEZ‐GIL, M., & PALACIOS, J. (1996) · Pacing and Clinical Electrophysiology · doi:10.1111/j.1540-8159.1996.tb03368.x · Cited by 111
Schumacher, B., Jung, W., Schmidt, H., Fischenbeck, C., Lewalter, T., Hagendorff, A., Omran, H., Wolpert, C., & Lüderitz, B. (1999) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(99)00211-9 · Cited by 104
Atrial arrhythmias during chronic follow-up of surgery for complex congenital heart disease
KANTER, R. J., & GARSON, A. (1997) · Pacing and Clinical Electrophysiology · doi:10.1111/j.1540-8159.1997.tb06207.x · Cited by 82
Metadata
- Authors
- De Bruyne, B., Bronzwaer, J. G., Heyndrickx, G. R., & Paulus, W. J.
- Venue
- Circulation
- Published
- 1993-08
- Volume
- 88
- Issue
- 2
- Pages
- 461-471
- ISSN
- 0009-7322 (ISSN-L)
- 1524-4539
- OpenAlex
- W2141476233
- Cited by
- 54
- References
- 0
- FWCI
- 2.69
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.