The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Echocardiographic follow-up of atrial septal defect after catheter closure by double-umbrella device.
Abstract
BACKGROUND: Transcatheter device occlusion of atrial septal defects is an attractive approach, but its efficacy and place in patient management remain to be determined. METHODS AND RESULTS: To evaluate the medium-term results of atrial septal defect device occlusion and factors influencing residual shunting, transesophageal and transthoracic echocardiograms of 49 patients were reviewed. Transesophageal echocardiograms on 48 patients immediately following surgical closure revealed residual shunting in 2% compared with 91% after device occlusion; this proportion decreased to 53% after a mean follow-up of 10 months. The actuarial analysis suggests a progressive resolution of shunting with time. One patient had residual shunting by transesophageal echocardiography immediately after surgical closure compared with 29 after a mean follow-up of 10 months after device occlusion. Residual shunting was not influenced by (1) dimension, location, or position with relation to the device as assessed by transesophageal echocardiography; (2) location of the defect; or (3) device size relative to the stretched dimension of the defect. In 15 patients, a poor correlation existed between transesophageal and transthoracic echocardiographic findings. Variability in serial transthoracic echocardiographic findings was observed in 14. Right ventricular dimension, heart size, and presence of a murmur at follow-up did not correlate with the presence or size of residual shunting after device occlusion. CONCLUSIONS: These results suggest that ongoing spontaneous resolution of residual shunting occurs after device insertion. Factors related to the defect or device could not predict eventual resolution of residual shunting. Transthoracic echocardiography in the follow-up of these patients may not be reliable in determining presence of residual shunting.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Murphy, J. G., Gersh, B. J., McGoon, M. D., Mair, D. D., Porter, C.-B. J., Ilstrup, D. M., McGoon, D. C., Puga, F. J., Kirklin, J. W., & Danielson, G. K. (1990) · New England Journal of Medicine · doi:10.1056/nejm199012133232401 · Cited by 776
Cited by
Du, Z.-D., Hijazi, Z. M., Kleinman, C. S., Silverman, N. H., & Larntz, K. (2002) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(02)01862-4 · Cited by 961
Holzer, R., Balzer, D., Cao, Q.-L., Lock, K., & Hijazi, Z. M. (2004) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2003.10.047 · Cited by 350
Transcatheter Closure of Perimembranous Ventricular Septal Defects
Butera, G., Carminati, M., Chessa, M., Piazza, L., Micheletti, A., Negura, D. G., Abella, R., Giamberti, A., & Frigiola, A. (2007) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2007.03.068 · Cited by 307
Fischer, G., Stieh, J., Uebing, A., Hoffmann, U., Morf, G., & Kramer, H. H. (2003) · Heart · doi:10.1136/heart.89.2.199 · Cited by 288
Closure of Atrial Septal Defects With the Amplatzer Occlusion Device: Preliminary Results
Thanopoulos, B. (. D., Laskari, C. V., Tsaousis, G. S., Zarayelyan, A., Vekiou, A., & Papadopoulos, G. S. (1998) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(98)00039-4 · Cited by 267
Metadata
- Authors
- Boutin, C., Musewe, N. N., Smallhorn, J. F., Dyck, J. D., Kobayashi, T., & Benson, L. N.
- Venue
- Circulation
- Published
- 1993-08
- Volume
- 88
- Issue
- 2
- Pages
- 621-627
- ISSN
- 0009-7322 (ISSN-L)
- 1524-4539
- OpenAlex
- W2057349741
- Cited by
- 197
- References
- 1
- FWCI
- 4.61
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Echocardiographic follow-up of atrial septal defect after catheter closure by double-umbrella device. https://app.cochat.ai/papers/10.1161/01.cir.88.2.621
- The paper
- Boutin, C., Musewe, N. N., Smallhorn, J. F., Dyck, J. D., Kobayashi, T., & Benson, L. N. (1993). Echocardiographic follow-up of atrial septal defect after catheter closure by double-umbrella device. Circulation. https://doi.org/10.1161/01.cir.88.2.621
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.