Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 268

The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.

Vascular complications after balloon and new device angioplasty.

Open access
Popma, J J, Satler, L F, Pichard, A D, Kent, K M, Campbell, A, Chuang, Y C, Clark, C, Merritt, A J, Bucher, T A, Leon, M B·1993·Circulation

Abstract

BACKGROUND: Despite their potential advantages, new coronary angioplasty devices may be associated with more frequent vascular complications than noted after standard balloon angioplasty, theoretically due to the larger sheaths and prolonged periods of anticoagulation required by some of these devices. This study sought to identify the incidence, predictors, and clinical outcome of vascular complications after new device angioplasty. METHODS AND RESULTS: The clinical course of 1413 patients was reviewed after balloon or new device angioplasty. Vascular complications were defined as formation of a pseudoaneurysm, arteriovenous fistula, retroperitoneal hematoma, or groin hematoma associated with a > 15-point hematocrit drop or the need for surgical repair. Stepwise logistic regression was used to identify independent predictors for vascular complications. Vascular complications developed after 84 (5.9%) procedures; they occurred more frequently after intracoronary stenting (14.0%) and extraction atherectomy (12.5%) than after balloon angioplasty (3.2%) (odds ratios, 4.86; P < .001, and 4.26, P < .05, respectively). Independent predictors of vascular complications included the use of intraprocedural thrombolytic agents (P < .01), intracoronary stenting (P < .005), or extraction atherectomy (P < .05); high maximum creatinine level (P < .005); low nadir platelet count (P < .001); longer periods of excess anticoagulation (P < .05); and the need for repeat coronary angioplasty (P < .005). Vascular complications were not related to the size of the arterial sheath used. CONCLUSIONS: Vascular complications developed more frequently after new device angioplasty than after balloon angioplasty, with the risk for vascular complications directly related to the degree of periprocedural anticoagulation.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1161/01.cir.88.4.1569

Cites

4 of 4 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 4 references

Cited by

See all 268

Metadata

Authors
Popma, J. J., Satler, L. F., Pichard, A. D., Kent, K. M., Campbell, A., Chuang, Y. C., Clark, C., Merritt, A. J., Bucher, T. A., & Leon, M. B.
Venue
Circulation
Published
1993-10
Volume
88
Issue
4
Pages
1569-1578
ISSN
  • 0009-7322 (ISSN-L)
  • 1524-4539
OpenAlex
W2076100790
Cited by
268
References
4
FWCI
14.60
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Vascular complications after balloon and new device angioplasty. https://app.cochat.ai/papers/10.1161/01.cir.88.4.1569
The paper
Popma, J. J., Satler, L. F., Pichard, A. D., Kent, K. M., Campbell, A., Chuang, Y. C., Clark, C., Merritt, A. J., Bucher, T. A., & Leon, M. B. (1993). Vascular complications after balloon and new device angioplasty. Circulation. https://doi.org/10.1161/01.cir.88.4.1569

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.