Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 303

The DOI matches its Crossref record; 8 of the 8 references it cites were found in a registry or an index.

A simple ultrasound approach for detection of recurrent proximal-vein thrombosis.

Prandoni, P, Cogo, A, Bernardi, E, Villalta, S, Polistena, P, Simioni, P, Noventa, F, Benedetti, L, Girolami, A · 1993 · Circulation

Abstract

BACKGROUND: The objective of this study was to develop a simple ultrasound method for measuring thrombus regression in patients with proximal deep-vein thrombosis (DVT) and to test its utility for the detection of DVT recurrence. METHODS AND RESULTS: The study comprised a cross-sectional survey and a prospective investigation (149 and 145 patients, respectively). In both phases, the normalization rate of a previously abnormal ultrasound test, applying the criterion of full compressibility of the common femoral and popliteal veins (C-US method), was assessed. In the prospective study, the vein diameter under maximum compression (thrombus thickness) was measured in the abnormal venous segments at scheduled times (1, 3, 6, and 12 months). In patients presenting with suspected DVT recurrence, the procedure was repeated and results were compared with those available from the previous examination. Noncompressibility of a previously normal(ized) venous segment and enlargement of thrombus thickness (> or = 2 mm) were considered diagnostic of proximal DVT recurrence. The diagnostic accuracy of the C-US method alone, as well as of the combined ultrasound methods (C-US + thrombus thickness), was assessed against contrast phlebography. C-US test normalization occurred in only 30% of patients within 1 year. A significant reduction of the thrombus mass (P < .0001) was recorded throughout the entire study period. However, a major decrease in thrombus mass (> 50%) was recorded within the first 3 months. Of 29 patients who developed a suspected recurrent DVT, phlebography confirmed diagnosis in 11. The C-US method alone showed an excellent accuracy (100%) but was applicable in only 6 patients (21%). Both the sensitivity and the specificity for proximal DVT recurrence of the combined ultrasound methods were 100% (95% confidence interval, 69% to 100% and 81% to 100%, respectively) and were applicable in all patients. CONCLUSIONS: The serial ultrasound measurement of thrombus mass after an acute episode of DVT may allow the correct identification of patients who develop a recurrent proximal-vein thrombosis.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1161/01.cir.88.4.1730

Cites

8 of 8 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 8 references

Cited by

See all 303

Metadata

Authors
Prandoni, P., Cogo, A., Bernardi, E., Villalta, S., Polistena, P., Simioni, P., Noventa, F., Benedetti, L., & Girolami, A.
Venue
Circulation
Published
1993-10
Volume
88
Issue
4
Pages
1730-1735
ISSN
  • 0009-7322 (ISSN-L)
  • 1524-4539
OpenAlex
W2143381739
Cited by
303
References
8
FWCI
3.49
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: A simple ultrasound approach for detection of recurrent proximal-vein thrombosis. https://app.cochat.ai/papers/10.1161/01.cir.88.4.1730
The paper
Prandoni, P., Cogo, A., Bernardi, E., Villalta, S., Polistena, P., Simioni, P., Noventa, F., Benedetti, L., & Girolami, A. (1993). A simple ultrasound approach for detection of recurrent proximal-vein thrombosis. Circulation. https://doi.org/10.1161/01.cir.88.4.1730

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.