CoChat

Diminished contractile response to increased heart rate in intact human left ventricular hypertrophy. Systolic versus diastolic determinants.

Open access
Liu, C P, Ting, C T, Lawrence, W, Maughan, W L, Chang, M S, Kass, D A · 1993 · Circulation
Cited by 142

The DOI matches its Crossref record.

Abstract

BACKGROUND: Experimental studies indicate that in addition to diastolic dysfunction, hypertrophied myocardium can display depressed contractile responses, particularly at rapid heart rates, compounding reserve limitations. This study tests whether such abnormalities exist in intact human subjects at physiological paced rates and, if so, whether they are linked to simultaneous rate-dependent deterioration in diastolic function. METHODS AND RESULTS: Ten subjects with left ventricular hypertrophy (LVH) and 8 normal control subjects were studied. Most LVH patients presented with dyspnea and/or pulmonary edema and had concentric hypertrophy. Since rapid pacing simultaneously alters cardiac filling volumes and pressures, pressure-volume relation analysis was used to better define changes in contractile response. Patients were instrumented with a conductance catheter and micromanometer for pressure-volume data recording and a balloon occluder at the right atrial-inferior vena caval junction to vary filling and thus generate function relations. Data were obtained at baseline and at three atrial pacing rates (100, 120, 150 min-1). In addition, single-beat force-interval data were used to indirectly examine calcium cycling kinetics. LVH subjects demonstrated baseline diastolic abnormalities, including prolonged relaxation, elevated end-diastolic pressure, and reduced chamber compliance. However, systolic function was similar to that in control subjects. With rapid pacing, normal subjects displayed a positive contractile response, whereas this was markedly diminished in LVH subjects. With abrupt termination of pacing and return to slower sinus rhythm, LVH subjects displayed greater initial potentiation followed by a more rapid decline than control subjects, suggesting abnormalities of calcium handling. Despite contractile abnormalities, diastolic function did not further deteriorate with rapid pacing and thus did not appear to be tightly linked to the systolic changes. CONCLUSIONS: Pacing stress in intact human LVH can result in systolic impairment superimposed on preexisting but not worsened diastolic dysfunction. Abnormal calcium handling probably contributes prominently to this response.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1161/01.cir.88.4.1893

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 142

Metadata

Authors
Liu, C. P., Ting, C. T., Lawrence, W., Maughan, W. L., Chang, M. S., & Kass, D. A.
Venue
Circulation
Published
1993-10
Volume
88
Issue
4
Pages
1893-1906
ISSN
  • 0009-7322 (ISSN-L)
  • 1524-4539
OpenAlex
W2114964520
Cited by
142
References
0
FWCI
1.87
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Diminished contractile response to increased heart rate in intact human left ventricular hypertrophy. Systolic versus diastolic determinants. https://app.cochat.ai/papers/10.1161/01.cir.88.4.1893
The paper
Liu, C. P., Ting, C. T., Lawrence, W., Maughan, W. L., Chang, M. S., & Kass, D. A. (1993). Diminished contractile response to increased heart rate in intact human left ventricular hypertrophy. Systolic versus diastolic determinants. Circulation. https://doi.org/10.1161/01.cir.88.4.1893

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.