CoChat

Identification of concealed posteroseptal Kent pathways by comparison of ventriculoatrial intervals from apical and posterobasal right ventricular sites.

Open access
Martínez-Alday, J D, Almendral, J, Arenal, A, Ormaetxe, J M, Pastor, A, Villacastín, J P, Medina, O, Peinado, R, Delcán, J L · 1994 · Circulation
Cited by 74

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Abstract

BACKGROUND: The differential diagnosis of supraventricular tachycardia with concentric atrial activation usually requires the inducibility of sustained tachycardia and needs a complex and time-consuming electrophysiological evaluation. To develop a simple test to establish if ventriculoatrial conduction uses a posteroseptal accessory pathway or the normal conduction system, we compared the ventriculoatrial intervals during right ventricular pacing from apical and posterobasal sites. METHODS AND RESULTS: Continuous pacing was performed from an apical and a posterobasal right ventricular site in 34 patients with retrograde conduction over the normal conduction system (group A) and in 22 patients with conduction over a posteroseptal accessory pathway (group B). During apical pacing, ventriculoatrial intervals in group A (176 +/- 40 milliseconds) were not significantly different than those in group B (197 +/- 47 milliseconds, P = NS). During posterobasal pacing, group B patients had significantly shorter ventriculoatrial intervals than group A patients (158 +/- 46 versus 197 +/- 39 milliseconds, P < .01). The difference between the ventriculoatrial interval obtained during apical pacing and that obtained during posterobasal pacing (ventriculoatrial index) discriminated between the two groups without overlapping: It was positive in all group B patients (39 +/- 19; range, +10 to +70 milliseconds) and negative in all except two group A patients (-21 +/- 13; range, -50 to +5 milliseconds; P < .001). CONCLUSIONS: This ventriculoatrial index can identify accurately and in the absence of tachycardia whether concentric retrograde conduction is proceeding over a posteroseptal accessory pathway or over the normal conduction system.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1161/01.cir.89.3.1060

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

Metadata

Authors
Martínez-Alday, J. D., Almendral, J., Arenal, A., Ormaetxe, J. M., Pastor, A., Villacastín, J. P., Medina, O., Peinado, R., & Delcán, J. L.
Venue
Circulation
Published
1994-03
Volume
89
Issue
3
Pages
1060-1067
ISSN
  • 0009-7322 (ISSN-L)
  • 1524-4539
OpenAlex
W2032504058
Cited by
74
References
1
FWCI
1.20
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.