The DOI matches its Crossref record.
Diagnostic and prognostic value of dipyridamole echocardiography in patients with suspected coronary artery disease. Comparison with exercise electrocardiography.
Abstract
BACKGROUND: Before any new diagnostic test is accepted in clinical practice, such a test should be compared with established diagnostic tools in an appropriately large series of patients encompassing the complete spectrum of challenges to which the test is exposed. The aim of the present study was to assess the relative diagnostic and prognostic accuracies of high-dose dipyridamole echocardiography (two-dimensional echocardiographic monitoring during dipyridamole infusion up to 0.84 mg/kg over 10 hours) versus maximal symptom-limited bicycle exercise ECG test in patients with angina. METHODS AND RESULTS: We studied 429 consecutive in-hospital patients who met the following inclusion criteria: history of chest pain, off antianginal therapy for at least 2 days (1 week for beta-blockers), no previous myocardial infarction and/or obvious regional left ventricular dyssynergy of contraction (akinesis or dyskinesis) at baseline, and acceptable acoustic window under resting conditions. All patients underwent dipyridamole echocardiography and exercise ECG--on different days and in random order--within 1 week of coronary angiography (which was performed independent of test results) and were followed up for 37.8 +/- 14 months (range, 1 to 73 months). Criteria of positivity were for dipyridamole echocardiography, a transient regional dyssynergy absent in the baseline examination; for exercise ECG, an ST-segment shift of > or = 0.1 mV from baseline; and for coronary angiography, a luminal reduction of > or = 75% in at least one major coronary vessel (50% for left main). There were 183 patients without and 246 with coronary artery disease; 132 had one-, 70 had two-, and 44 had three- and/or left main vessel disease. The specificity was higher for dipyridamole echocardiography than for exercise ECG (90% versus 51%, P < .001). The overall sensitivity of dipyridamole echocardiography was similar to that of exercise ECG (75% versus 74%, P = NS), with no significant differences in the subset with one- (67% versus 69%, P = NS), two- (79% versus 77%, P = NS), or three- (93% versus 86%, P = NS) vessel disease. During the follow-up, there were 20 deaths, 13 nonfatal myocardial infarctions, and 126 revascularization procedures. In the univariate analysis, dipyridamole resulted in higher chi 2 values than did exercise stress testing. A Cox forward stepwise survival analysis identified the dipyridamole time as the most powerful prognostic predictor of death (chi 2 = 19.4, P < .0001) of all invasive and noninvasive parameters. The dipyridamole time also provided independent and additional prognostic information when it was adjusted for age, diabetes, resting ECG, and exercise stress test according to a modified, interactive stepwise procedure. This is true when death only, death and myocardial infarction, and death, myocardial infarction, and revascularization procedures were considered end points. CONCLUSIONS: In patients with no previous myocardial infarction and good resting left ventricular function, compared with exercise ECG, dipyridamole echocardiography has a similar sensitivity and a higher specificity for the noninvasive detection of angiographically assessed coronary artery disease. Dipyridamole echocardiography also provides information in addition to that provided by exercise ECG for predicting death, infarction, and all events when the presence as well as the timing, severity, and extension of dipyridamole-induced wall motion abnormalities are considered.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
ACC/AHA/ASE 2003 guideline update for the clinical application of echocardiography: summary article
Cheitlin, M. D., Armstrong, W. F., Aurigemma, G. P., Beller, G. A., Bierman, F. Z., Davis, J. L., Douglas, P. S., Faxon, D. P., Gillam, L. D., Kimball, T. R., et al. (2003) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(03)01065-9 · Cited by 1,402
Sicari, R., Nihoyannopoulos, P., Evangelista, A., Kasprzak, J., Lancellotti, P., Poldermans, D., Voigt, J.-U., Zamorano, J. L., & on behalf of the European Association of Echocardiography (2008) · European Journal of Echocardiography · doi:10.1093/ejechocard/jen175 · Cited by 717
Mulvagh, S. L., Rakowski, H., Vannan, M. A., Abdelmoneim, S. S., Becher, H., Bierig, S. M., Burns, P. N., Castello, R., Coon, P. D., Hagen, M. E., et al. (2008) · Journal of the American Society of Echocardiography · doi:10.1016/j.echo.2008.09.009 · Cited by 492
Low-T3 syndrome: a strong prognostic predictor of death in patients with heart disease
Iervasi, G., Pingitore, A., Landi, P., Raciti, M., Ripoli, A., Scarlattini, M., L’Abbate, A., & Donato, L. (2003) · Circulation · doi:10.1161/01.cir.0000048124.64204.3f · Cited by 472
Self-citationMieres, J. H., Shaw, L. J., Arai, A., Budoff, M. J., Flamm, S. D., Hundley, W. G., Marwick, T. H., Mosca, L., Patel, A. R., Quinones, M. A., et al. (2005) · Circulation · doi:10.1161/01.cir.0000155233.67287.60 · Cited by 469
Metadata
- Authors
- Severi, S., Picano, E., Michelassi, C., Lattanzi, F., Landi, P., Distante, A., & L'Abbate, A.
- Venue
- Circulation
- Published
- 1994-03
- Volume
- 89
- Issue
- 3
- Pages
- 1160-1173
- ISSN
- 0009-7322 (ISSN-L)
- 1524-4539
- OpenAlex
- W2058446870
- Cited by
- 178
- References
- 0
- FWCI
- 13.37
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Diagnostic and prognostic value of dipyridamole echocardiography in patients with suspected coronary artery disease. Comparison with exercise electrocardiography. https://app.cochat.ai/papers/10.1161/01.cir.89.3.1160
- The paper
- Severi, S., Picano, E., Michelassi, C., Lattanzi, F., Landi, P., Distante, A., & L'Abbate, A. (1994). Diagnostic and prognostic value of dipyridamole echocardiography in patients with suspected coronary artery disease. Comparison with exercise electrocardiography. Circulation. https://doi.org/10.1161/01.cir.89.3.1160
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.