The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Dynamics of mitral regurgitant flow and orifice area. Physiologic application of the proximal flow convergence method: clinical data and experimental testing.
Abstract
BACKGROUND: The proximal flow convergence method, a quantitative color Doppler flow technique, has been validated recently for calculating regurgitant flow and orifice area. We investigated the potential of the method as a tool to study different pathophysiological mechanisms of mitral valve incompetence by assessing the time course of regurgitant flow and orifice area and analyzed the implications for quantification of mitral regurgitation. METHODS AND RESULTS: Fifty-six consecutive patients with mitral regurgitation of different etiologies were studied. The instantaneous regurgitant flow rate Q(t) was computed from color M-mode recordings of the proximal flow convergence region and divided by the corresponding orifice velocity V(t) to obtain the instantaneous orifice area A(t). Regurgitant stroke volume (RSV) was obtained by integrating Q(t). Mean regurgitant flow rate Qm was calculated by RSV divided by regurgitation time. Peak-to-mean regurgitant flow rates Qp/Qm and orifice areas Ap/Am were calculated to assess the phasic character of Q(t) and A(t). In the first 24 patients (group 1), computation of Qm and RSV from the color Doppler recordings was compared with the conventional pulsed Doppler method (r = .94, SEE = 29.4 mL/s and r = .95, SEE = 9.7 mL) as well as with angiography (rs = .93 and rs = .94, P < .001). The temporal variation of Q(t) and A(t) was studied in the next 32 patients (group 2): In functional regurgitation in dilated cardiomyopathy (n = 12), there was a constant decrease in A(t) throughout systole with an increase during left ventricular relaxation; Ap/Am was 5.49 +/- 3.17. In mitral valve prolapse (n = 6), A(t) was small in early systole, increasing substantially in midsystole, and decreasing mildly during left ventricular relaxation; Ap/Am was 2.48 +/- 0.26. In rheumatic mitral regurgitation (n = 14), a roughly constant regurgitant orifice area during most of systole was found in 4 patients. In the other patients there was significant variation of A (t) and the time of its maximum; Ap/Am was 1.81 +/- 0.56. ANOVA demonstrated that the differences in Ap/Am were related to the etiology of mitral regurgitation (P < .0001). To verify that the calculated variation in regurgitant orifice area during the cardiac cycle reflects an actual variation, the ability of the method to predict a constant orifice area throughout systole was tested experimentally in a canine model of mitral regurgitation. Five flow stages were produced by implanting fixed grommet orifices of different sizes into the anterior mitral leaflet. A constant regurgitant orifice area was correctly predicted throughout systole with a mean percent error of -1.8 +/- 4% (from -6.9% to +5.8%); the standard deviation of the individual curves calculated at 10% intervals during systole averaged 13.3% (from 3.6% to 19.6%). In addition, functional mitral regurgitation caused by ventricular dysfunction was produced pharmacologically in five dogs, and the color M-mode recordings of the proximal flow convergence region were obtained with the transducer placed directly on the heart instead of the chest, thus ruling out a significant effect of translational motion on the observed flow pattern. The pattern of regurgitant flow variation was identical to that observed in patients. CONCLUSIONS: The proximal flow convergence method demonstrates that regurgitant flow and orifice area vary throughout systole in distinct patterns characteristic of the underlying mechanism of mitral incompetence. Therefore, in addition to the potential of the method as a tool to quantify mitral regurgitation, it allows analysis of the pathophysiology of regurgitation in the individual patient, which may be helpful in clinical decision making. Calculating mitral regurgitant flow rate and volume from the time-varying proximal flow field (ie, without assuming a constant orifice area that would produce overestimation in individual patients) provides excellent agreement with independent te
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
Martin Bland, J., & Altman, D. (1986) · The Lancet · doi:10.1016/s0140-6736(86)90837-8 · Cited by 47,965
Cited by
Breithardt, O. A., Sinha, A. M., Schwammenthal, E., Bidaoui, N., Markus, K. U., Franke, A., & Stellbrink, C. (2003) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(02)02937-6 · Cited by 517
Self-citationMitral valve disease—morphology and mechanisms
Levine, R. A., Hagége, A. A., Judge, D. P., Padala, M., Dal-Bianco, J. P., Aikawa, E., Beaudoin, J., Bischoff, J., Bouatia-Naji, N., Bruneval, P., et al. (2015) · Nature Reviews Cardiology · doi:10.1038/nrcardio.2015.161 · Cited by 386
Self-citation
Metadata
- Authors
- Schwammenthal, E., Chen, C., Benning, F., Block, M., Breithardt, G., & Levine, R. A.
- Venue
- Circulation
- Published
- 1994-07
- Volume
- 90
- Issue
- 1
- Pages
- 307-322
- ISSN
- 0009-7322 (ISSN-L)
- 1524-4539
- OpenAlex
- W1970602559
- Cited by
- 294
- References
- 1
- FWCI
- 7.19
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Dynamics of mitral regurgitant flow and orifice area. Physiologic application of the proximal flow convergence method: clinical data and experimental testing. https://app.cochat.ai/papers/10.1161/01.cir.90.1.307
- The paper
- Schwammenthal, E., Chen, C., Benning, F., Block, M., Breithardt, G., & Levine, R. A. (1994). Dynamics of mitral regurgitant flow and orifice area. Physiologic application of the proximal flow convergence method: clinical data and experimental testing. Circulation. https://doi.org/10.1161/01.cir.90.1.307
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.