CoChat

Myocardial High-Energy Phosphate and Substrate Metabolism in Swine With Moderate Left Ventricular Hypertrophy

Massie, Barry M., Schaefer, Saul, Garcia, Jorge, McKirnan, M. Dan, Schwartz, Gregory G., Wisneski, Judith A., Weiner, Michael W., White, Francis C. · 1995 · Circulation
Cited by 90

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Abstract

Background Although left ventricular hypertrophy (LVH) is frequently associated with impaired coronary vasodilator reserve, it is uncertain whether this leads to myocardial ischemia under physiological conditions. The goal of the present study was to determine whether swine with moderate LVH exhibit metabolic evidence of ischemia when myocardial oxygen requirements are increased. Methods and Results Myocardial metabolism was evaluated in an open-chest anesthetized preparation at baseline and during dobutamine infusion in 13 adolescent pigs with moderate LVH induced by supravalvular aortic banding and 12 age-matched control pigs. Transmural myocardial blood flow was quantified with radioactive microspheres; the ratio of phosphocreatine to ATP (PCr/ATP) in the anterior LV free wall was measured by 31 P–nuclear magnetic resonance; and anterior wall lactate release was quantified from the arterial-coronary venous difference in 14 C- or 13 C-labeled lactate. In a subset of 5 animals from each group, the metabolic fate of exogenous glucose was determined from the transmyocardial difference in 6- 14 C-glucose and its metabolites 14 C-lactate and 14 CO 2 . Coronary reserve, as assessed by the ratio of blood flow during adenosine infusion to baseline blood flow, was significantly lower in the LVH pigs compared with controls (3.5±0.4 versus 5.5±0.4 mL/g · min, P <.05); however, transmural myocardial blood flow was similar in both groups of pigs, both at baseline and with dobutamine stimulation, probably reflecting the higher coronary perfusion pressure in the LVH pigs. At baseline, PCr/ATP tended to be lower in the LVH pigs ( P =.09) but decreased similarly with dobutamine infusion in both groups. Isotopically measured anterior wall lactate release did not differ between the groups at baseline, nor did the increase in lactate release differ during dobutamine stimulation. The uptake of glucose, lactate, and free fatty acids did not differ between the groups in the basal state. However, during dobutamine stimulation, glucose uptake was greater in the LVH group (0.84±0.09 μmol/g · min versus 0.59±0.08 μmol/g · min, P <.05). In a subset of animals, 14 C-glucose was used to assess glucose oxidation. These data showed that the LVH animals had a greater rate of glucose oxidation (0.60±0.10 versus 0.28±0.08 μmol/g · min, P <.05) and a greater rate of glucose conversion to lactate (0.20±0.04 versus 0.09±0.02 μmol/g · min, P <.05) compared with the control pigs. Conclusions These results suggest that despite their reduced coronary vasodilator reserve and the absence of a greater rise in myocardial blood flow to compensate for a substantially higher LV double product, pigs with this model of moderate LVH do not exhibit a greater susceptibility to myocardial ischemia during dobutamine stress. However, LVH pigs exhibit significantly greater use of exogenous glucose during dobutamine stress, as evidenced by increases in both glucose oxidation and anaerobic glycolysis.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1161/01.cir.91.6.1814

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 2 references

Cited by

Metadata

Authors
Massie, B. M., Schaefer, S., Garcia, J., McKirnan, M. D., Schwartz, G. G., Wisneski, J. A., Weiner, M. W., & White, F. C.
Venue
Circulation
Published
1995-03-15
Volume
91
Issue
6
Pages
1814-1823
ISSN
  • 0009-7322 (ISSN-L)
  • 1524-4539
OpenAlex
W2074886785
Cited by
90
References
2
FWCI
3.84
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.