Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 231

The DOI matches its Crossref record.

Results of the International Study of the Implantable Pacemaker Cardioverter-Defibrillator: A Comparison of Epicardial and Endocardial Lead Systems

Zipes, Douglas P., Roberts, Diana · 1995 · Circulation

Abstract

Background The purpose of the present report was to document clinical experience derived from the implantation of 2834 epicardial and endocardial cardioverter-defibrillators (ICDs) in 2807 patients who were followed for almost 1 year and to compare the results obtained with the two systems. Methods and Results Patients in the two groups had similar clinical characteristics. More than half of the patients had a total of almost 50 000 spontaneous ventricular tachyarrhythmias that were terminated with equal success (≈98%) by epicardial and endocardial ICDs. Lead dislodgement and pocket infection occurred more often with the endocardial than with the epicardial ICD, whereas perioperative mortality was higher with the epicardial ICD than with the endocardial ICD. Mortality from sudden cardiac death was 1.4% in the epicardial ICD group and 0.6% in the endocardial ICD group at 1 year ( P =.069). Overall mortality at 1 year was 12.2% and 6.9% for the epicardial and endocardial groups, respectively ( P <.001), reflecting the higher surgical mortality for the epicardial system. Conclusions The endocardial ICD is as effective as the epicardial ICD but incurs lower perioperative mortality.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1161/01.cir.92.1.59

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 231

Metadata

Authors
Zipes, D. P., & Roberts, D.
Venue
Circulation
Published
1995-07
Volume
92
Issue
1
Pages
59-65
ISSN
  • 0009-7322 (ISSN-L)
  • 1524-4539
OpenAlex
W1975706928
Cited by
231
References
0
FWCI
19.49
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Results of the International Study of the Implantable Pacemaker Cardioverter-Defibrillator: A Comparison of Epicardial and Endocardial Lead Systems. https://app.cochat.ai/papers/10.1161/01.cir.92.1.59
The paper
Zipes, D. P., & Roberts, D. (1995). Results of the International Study of the Implantable Pacemaker Cardioverter-Defibrillator: A Comparison of Epicardial and Endocardial Lead Systems. Circulation. https://doi.org/10.1161/01.cir.92.1.59

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.